SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kitlinski Mariusz) "

Sökning: WFRF:(Kitlinski Mariusz)

  • Resultat 1-10 av 20
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Gudmundsson, Petri, et al. (författare)
  • Head to head comparisons of two modalities of perfusion adenosine stress echocardiography with simultaneous SPECT
  • 2009
  • Ingår i: Cardiovascular Ultrasound. - : BioMed Central. - 1476-7120. ; 7:19
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Real-time perfusion (RTP) contrast echocardiography can be used during adenosine stress echocardiography (ASE) to evaluate myocardial ischemia. We compared two different types of RTP power modulation techniques, angiomode (AM) and high-resolution grayscale (HR), with 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) for the detection of myocardial ischemia. Methods: Patients with known or suspected coronary artery disease (CAD), admitted to SPECT, were prospectively invited to participate. Patients underwent RTP imaging (SONOS 5500) using AM and HR during Sonovue® infusion, before and throughout the adenosine stress, also used for SPECT. Analysis of myocardial perfusion and wall motion by RTP-ASE were done for AM and HR at different time points, blinded to one another and to SPECT. Each segment was attributed to one of the three main coronary vessel areas of interest. Results: In 50 patients, 150 coronary areas were analyzed by SPECT and RTP-ASE AM and HR. SPECT showed evidence of ischemia in 13 out of 50 patients. There was no significant difference between AM and HR in detecting ischemia (p = 0.08). The agreement for AM and HR, compared to SPECT, was 93% and 96%, with Kappa values of 0.67 and 0.75, respectively (p < 0.001). Conclusion: There was no significant difference between AM and HR in correctly detecting myocardial ischemia as judged by SPECT. This suggests that different types of RTP modalities give comparable data during RTP-ASE in patients with known or suspected CAD.
  •  
2.
  •  
3.
  • Gudmundsson, Petri, et al. (författare)
  • Parametric quantification of myocardial ischaemia using real-time perfusion adenosine stress echocardiography images, with SPECT as reference method
  • 2010
  • Ingår i: Clinical Physiology and Functional Imaging. - : John Wiley & Sons. - 1475-0961 .- 1475-097X. ; 30:1, s. 30-42
  • Tidskriftsartikel (refereegranskat)abstract
    • SUMMARY BACKGROUND: Real-time perfusion (RTP) adenosine stress echocardiography (ASE) can be used to visually evaluate myocardial ischaemia. The RTP power modulation technique, provides images for off-line parametric perfusion quantification using Qontrast software. From replenishment curves, this generates parametric images of peak signal intensity (A), myocardial blood flow velocity (beta) and myocardial blood flow (Axbeta) at rest and stress. This may be a tool for objective myocardial ischaemia evaluation. We assessed myocardial ischaemia by RTP-ASE Qontrast((R))-generated images, using 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) as reference. METHODS: Sixty-seven patients admitted to SPECT underwent RTP-ASE (SONOS 5500) during Sonovue infusion, before and throughout adenosine stress, also used for SPECT. Quantitative off-line analyses of myocardial perfusion by RTP-ASE Qontrast-generated A, beta and Axbeta images, at different time points during rest and stress, were blindly compared to SPECT. RESULTS: We analysed 201 coronary territories [corresponding to the left anterior descendent (LAD), left circumflex (LCx) and right coronary (RCA) arteries] from 67 patients. SPECT showed ischaemia in 18 patients. Receiver operator characteristics and kappa values showed that A, beta and Axbeta image interpretation significantly identified ischaemia in all territories (area under the curve 0.66-0.80, P = 0.001-0.05). Combined A, beta and Axbeta image interpretation gave the best results and the closest agreement was seen in the LAD territory: 89% accuracy; kappa 0.63; P<0.001. CONCLUSION: Myocardial isachemia can be evaluated in the LAD territory using RTP-ASE Qontrast-generated images, especially by combined A, beta and Axbeta image interpretation. However, the technique needs improvements regarding the LCx and RCA territories.
  •  
4.
  •  
5.
  •  
6.
  • Gudmundsson, Petri, et al. (författare)
  • Quantitative detection of myocardial ischaemia by stress echocardiography; a comparison with SPECT
  • 2009
  • Ingår i: Cardiovascular Ultrasound. - : BioMed Central. - 1476-7120. ; 7:28
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Real-time perfusion (RTP) adenosine stress echocardiography (ASE) can be used to visually evaluate myocardial ischaemia. The RTP power modulation technique angio-mode (AM), provides images for off-line perfusion quantification using Qontrast® software, generating values of peak signal intensity (A), myocardial blood flow velocity (β) and myocardial blood flow (Axβ). By comparing rest and stress values, their respective reserve values (A-r, β-r, Axβ-r) are generated. We evaluated myocardial ischaemia by RTP-ASE Qontrast® quantification, compared to visual perfusion evaluation with 99mTc-tetrofosmin singlephoton emission computed tomography (SPECT). Methods and Results: Patients admitted to SPECT underwent RTP-ASE (SONOS 5500) using AM during Sonovue® infusion, before and throughout adenosine stress, also used for SPECT. Visual myocardial perfusion and wall motion analysis, and Qontrast® quantification, were blindly compared to one another and to SPECT, at different time points off-line. We analyzed 201 coronary territories (left anterior descendent [LAD], left circumflex [LCx] and right coronary [RCA] artery territories) in 67 patients. SPECT showed ischaemia in 18 patients and 19 territories. Receiver operator characteristics and kappa values showed significant agreement with SPECT only for β-r and Axβ-r in all segments: area under the curve 0.678 and 0.665; P < 0.001 and < 0.01, respectively. The closest agreements were seen in the LAD territory: kappa 0.442 for both β-r and Axβ- r; P < 0.01. Visual evaluation of ischaemia showed good agreement with SPECT: accuracy 93%; kappa 0.67; P < 0.001; without non-interpretable territories. Conclusion: In this agreement study with SPECT, RTP-ASE Qontrast® quantification of myocardial ischaemia was less accurate and less feasible than visual evaluation and needs further development to be clinically useful.
  •  
7.
  •  
8.
  •  
9.
  • Kolarzyk, Emilia, et al. (författare)
  • The usefulness of artificial neural networks in the evaluation of pulmonary efficiency and antioxidant capacity of welders
  • 2006
  • Ingår i: International Journal of Hygiene and Environmental Health. - : Elsevier BV. - 1618-131X .- 1438-4639. ; 209:4, s. 385-392
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The aim of the study was to determine if artificial neural networks (ANNs) may be useful to analyse a complex and large set of data derived from smoking welders for the purpose of finding relationships between parameters describing respiratory system efficiency and antioxidant defence. Methods: A group of 94 welders employed in a big metallurgic enterprise in Krakow, Poland (men only, aged 29-57 years, all active smokers) occupationally exposed to 03 and NO,, were the subjects of this study. They underwent biochemical measurements including total antioxidant status (TAS) and the anti-oxidative defence enzymes superoxide dismutase (SOD) and catalase (CT); biominerals: Fe, Cu, Zn, Mg in blood serum and in hair; the concentrations of albumin, bilirubin, uric acid in blood. The determination of respiratory efficiency was based on a "flow-volume" curve and spirometry. The dependant variables for ANNs were: TAS, SOD, CT. Thirty-one subjects with normal values of all spirometric parameters were selected for the final analysis. Results: Statistically valid relationship between TAS and albumin, Zn and Cu in blood and the two pulmonary parameters forced expiratory volume after I s (FEV1) and middle expiratory flow of 25-75% of vital capacity (MEF25/75) were found. Zn concentration almost linearly influenced TAS. For Cu a sigmoid curve was obtained. For albumin concentration as well as for FEV1 a two-stage curve was observed. Conclusions: ANNs are useful for the reduction of dimensionality and are suited to analyse a complex and relatively large set of parameters when it is unknown which of these are related. ANNs were useful for finding the relationship between the antioxidant defence and the respiratory system capacity in welders who smoke. (c) 2006 Elsevier GmbH. All rights reserved.
  •  
10.
  • Nessler, J, et al. (författare)
  • C-reactive protein as a marker of heart failure.
  • 2004
  • Ingår i: Brief Communications of the International Congress on Valvular Heart Disease (Acta Cardiologica). - 0001-5385. ; 59:2, s. 217-218
  • Konferensbidrag (refereegranskat)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 20

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy