SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Klamra Wlodzimierz) "

Sökning: WFRF:(Klamra Wlodzimierz)

  • Resultat 1-10 av 79
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abdo, A. A., et al. (författare)
  • FERMI LARGE AREA TELESCOPE OBSERVATIONS OF THE VELA PULSAR
  • 2009
  • Ingår i: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 696:2, s. 1084-1093
  • Tidskriftsartikel (refereegranskat)abstract
    • The Vela pulsar is the brightest persistent source in the GeV sky and thus is the traditional first target for new gamma-ray observatories. We report here on initial Fermi Large Area Telescope observations during verification phase pointed exposure and early sky survey scanning. We have used the Vela signal to verify Fermi timing and angular resolution. The high-quality pulse profile, with some 32,400 pulsed photons at E >= 0.03 GeV, shows new features, including pulse structure as fine as 0.3 ms and a distinct third peak, which shifts in phase with energy. We examine the high-energy behavior of the pulsed emission; initial spectra suggest a phase-averaged power-law index of Gamma = 1.51(-0.04)(+0.05) with an exponential cutoff at E-c = 2.9 +/- 0.1 GeV. Spectral fits with generalized cutoffs of the form e(-(E/Ec)b) require b <= 1, which is inconsistent with magnetic pair attenuation, and thus favor outer-magnetosphere emission models. Finally, we report on upper limits to any unpulsed component, as might be associated with a surrounding pulsar wind nebula.
  •  
2.
  • Abdo, A. A., et al. (författare)
  • The on-orbit calibration of the Fermi Large Area Telescope
  • 2009
  • Ingår i: Astroparticle physics. - : Elsevier BV. - 0927-6505 .- 1873-2852. ; 32:3-4, s. 193-219
  • Tidskriftsartikel (refereegranskat)abstract
    • The Large Area Telescope (LAT) on-board the Fermi Gamma-ray Space Telescope began its on-orbit operations on June 23, 2008. Calibrations, defined in a generic sense, correspond to synchronization of trigger signals, optimization of delays for latching data, determination of detector thresholds, gains and responses, evaluation of the perimeter of the South Atlantic Anomaly (SAA), measurements of live time, of absolute time, and internal and spacecraft boresight alignments. Here we describe on-orbit calibration results obtained using known astrophysical sources, galactic cosmic rays, and charge injection into the front-end electronics of each detector. Instrument response functions will be described in a separate publication. This paper demonstrates the stability of calibrations and describes minor changes observed since launch. These results have been used to calibrate the LAT datasets to be publicly released in August 2009.
  •  
3.
  • Andersson, V., et al. (författare)
  • Large-Area Balloon-Borne Polarized Gamma Ray Observer (PoGO)
  • 2005
  • Ingår i: Proceedings of the 22nd Texas Symposium on Relativistic Astrophysics at Stanford. ; , s. 736-743
  • Konferensbidrag (refereegranskat)abstract
    • We are developing a new balloon-borne instrument (PoGO), to measure polarization of soft gamma rays (30-200 keV) using asymmetry in azimuth angle distribution of Compton scattering. PoGO is designed to detect 10 % polarization in 100mCrab sources in a 6-8 hour observation and bring a new dimension to studies on gamma ray emission/transportation mechanism in pulsars, AGNs, black hole binaries, and neutron star surface. The concept is an adaptation to polarization measurements of well-type phoswich counter consisting of a fast plastic scintillator (the detection part), a slow plastic scintillator (the active collimator) and a BGO scintillator (the bottom anti-counter). PoGO consists of close-packed array of 217 hexagonal well-type phoswich counters and has a narrow field-of-view (~ 5 deg2) to reduce possible source confusion. A prototype instrument has been tested in the polarized soft gamma-ray beams at Advanced Photon Source (ANL) and at Photon Factory (KEK). On the results, the polarization dependence of EGS4 has been validated and that of Geant4 has been corrected.
  •  
4.
  • Arimoto, M., et al. (författare)
  • Performance assessment study of the balloon-borne astronomical soft gamma-ray polarimeter PoGOLite
  • 2007
  • Ingår i: Physica. E, Low-Dimensional systems and nanostructures. - : Elsevier BV. - 1386-9477 .- 1873-1759. ; 40:2, s. 438-441
  • Tidskriftsartikel (refereegranskat)abstract
    • Measurements of polarization play a crucial role in the understanding of the dominant emission mechanism of astronomical sources. Polarized Gamma-ray Observer-Light version (PoGOLite) is a balloon-borne astronomical soft gamma-ray polarimeter at the 25-80 keV band. The PoGOLite detector consists of a hexagonal close-packed array of 217 Phoswich detector cells (PDCs) and side anti-coincidence shields (SASs) made of BGO crystals surrounding PDCs. Each PDC consists of a slow hollow scintillator, a fast scintillator and a BGO crystal that connects to a photomultiplier tube at the end. To examine the PoGOLite's capability and estimate the performance, we conducted experiments with the PDC using radioisotope 241Am. In addition, we compared this result with performance expected by Monte Carlo simulation with Geant4. As a result, we found that the actual PDC has the capability to detect a 100 m Crab source until 80 keV.
  •  
5.
  • Atwood, W. B., et al. (författare)
  • THE LARGE AREA TELESCOPE ON THE FERMI GAMMA-RAY SPACE TELESCOPE MISSION
  • 2009
  • Ingår i: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 697:2, s. 1071-1102
  • Tidskriftsartikel (refereegranskat)abstract
    • The Large Area Telescope (Fermi/LAT, hereafter LAT), the primary instrument on the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view (FoV), high-energy gamma-ray telescope, covering the energy range from below 20 MeV to more than 300 GeV. The LAT was built by an international collaboration with contributions from space agencies, high-energy particle physics institutes, and universities in France, Italy, Japan, Sweden, and the United States. This paper describes the LAT, its preflight expected performance, and summarizes the key science objectives that will be addressed. On-orbit performance will be presented in detail in a subsequent paper. The LAT is a pair-conversion telescope with a precision tracker and calorimeter, each consisting of a 4 x 4 array of 16 modules, a segmented anticoincidence detector that covers the tracker array, and a programmable trigger and data acquisition system. Each tracker module has a vertical stack of 18 (x, y) tracking planes, including two layers (x and y) of single-sided silicon strip detectors and high-Z converter material (tungsten) per tray. Every calorimeter module has 96 CsI(Tl) crystals, arranged in an eight-layer hodoscopic configuration with a total depth of 8.6 radiation lengths, giving both longitudinal and transverse information about the energy deposition pattern. The calorimeter's depth and segmentation enable the high-energy reach of the LAT and contribute significantly to background rejection. The aspect ratio of the tracker (height/width) is 0.4, allowing a large FoV (2.4 sr) and ensuring that most pair-conversion showers initiated in the tracker will pass into the calorimeter for energy measurement. Data obtained with the LAT are intended to (1) permit rapid notification of high-energy gamma-ray bursts and transients and facilitate monitoring of variable sources, (2) yield an extensive catalog of several thousand high-energy sources obtained from an all-sky survey, (3) measure spectra from 20 MeV to more than 50 GeV for several hundred sources, (4) localize point sources to 0.3-2 arcmin, (5) map and obtain spectra of extended sources such as SNRs, molecular clouds, and nearby galaxies, (6) measure the diffuse isotropic gamma-ray background up to TeV energies, and (7) explore the discovery space for dark matter.
  •  
6.
  • Axelsson, Magnus, et al. (författare)
  • Measuring energy dependent polarization in soft gamma-rays using compton scattering in PoGOLite
  • 2007
  • Ingår i: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 28:3, s. 327-337
  • Tidskriftsartikel (refereegranskat)abstract
    • Linear polarization in X-and gamma-rays is an important diagnostic of many astrophysical sources, foremost giving information about their geometry, magnetic fields, and radiation mechanisms. However, very few X-ray polarization measurements have been made, and then only mono-energetic detections, whilst several objects are assumed to have energy dependent polarization signatures. In this paper, we investigate whether detection of energy dependent polarization from cosmic sources is possible using the Compton technique, in particular with the proposed PoGOLite balloon-experiment, in the 25-100 keV range. We use Geant4 simulations of a PoGOLite model and input photon spectra based on Cygnus X-1 and accreting magnetic pulsars (100 mCrab). Effective observing times of 6 and 35 h were simulated, corresponding to a standard and a long duration flight, respectively. Both smooth and sharp energy variations of the polarization are investigated and compared to constant polarization signals using chi-square statistics. We can reject constant polarization, with energy, for the Cygnus X-1 spectrum (in the hard state), if the reflected component is assumed to be completely polarized, whereas the distinction cannot be made for weaker polarization. For the accreting pulsar, constant polarization can be rejected in the case of polarization in a narrow energy band with at least 50% polarization, and similarly for a negative step distribution from 30% to 0% polarization.
  •  
7.
  • Balcerzyk, M., et al. (författare)
  • Energy resolution and light yield non-proportionality of ZnSe : Te scintillator studied by large area avalanche photodiodes and photomultipliers
  • 2002
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 482:3, s. 720-727
  • Tidskriftsartikel (refereegranskat)abstract
    • The ZnSe: Te scintillator has been studied by means of a photomultiplier with an extended bialkali photocathode, a large area avalanche photodiode (LAAPD) and a PIN photodiode. The light output was determined to be 28 300+/-1700 photons/MeV. Results indicate good proportionality for light output versus gamma-ray energy. Measurements of the 662 keV gamma-ray energy spectrum recorded using a LAAPD resulted in an energy resolution of 5.4+/-0.3%. Based on these results, an intrinsic energy resolution of 3.3+/-0.7% has been calculated.
  •  
8.
  • Bäck, Torbjörn, et al. (författare)
  • A TOF-PET system for educational purposes
  • 2002
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 477, s. 82-82
  • Tidskriftsartikel (refereegranskat)abstract
    • A TOF-PET system has been designed and constructed for educational purposes. The aim of this system is to demonstrate the possibilities of positron emission tomography in general and the time-of-flight method in particular to the students of various courses at the Royal Institute of Technology, Stockholm, Sweden. The set-up consists of 48 small BaF2 crystals coupled to fast photomultipliers placed in a ring geometry. The signals of the photomultipliers are fed into fast constant fraction discriminators (CFD). The outputs of these are directed to a specially designed logic VME unit. which combines the CFD signals of 6 neighbouring channels to one signal by adding a different delay to each channel. The logic circuitry produces a prompt pulse for each event that serves as the start pulse for the 8-channel fast TDC. The delayed pulses act as the stop pulses for the TDC. In a computer. the measured times are converted into information about which the photomultipliers fired with the difference in the time of flight. The set-up is described and the results are presented.
  •  
9.
  • Bäck, Torbjörn, et al. (författare)
  • An educational tool for demonstrating the TOF-PET technique
  • 2001
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : AMERICAN PHYSICAL SOC. - 0168-9002 .- 1872-9576. ; 471:1-2, s. 200-204
  • Tidskriftsartikel (refereegranskat)abstract
    • A detector system for positron emission tomography with time-of-flight capability has been built to serve as an educational tool for undergraduate students. The set-up consists of 48 BaF2 scintillator crystals, each coupled to a fast photo-multiplier tube, mounted in a circular geometry. The analogue detector pulses are handled by fast constant fraction discriminators. A dedicated unit reduces the 48 channels to eight channels via delay-fine encoding, and the signals are then fed to an eight channel fast time-to-digital converter. A VME processor sorts the events and sends them to a workstation where the coincident events are extracted. The time resolution of the detectors together with fast VME based electronics allows for time-of-flight measurements to improve on the signal-to-noise ratio in the, reconstructed images. The system can be used for different types of exercises for the students, varying from the fundamentals of scintillator detectors to advanced image reconstruction. The set-up is described and some results are presented. (C) 2001 Elsevier Science B.V. All rights reserved.
  •  
10.
  • Carasco, C., et al. (författare)
  • In-field tests of the EURITRACK tagged neutron inspection system
  • 2008
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 588:3, s. 397-405
  • Tidskriftsartikel (refereegranskat)abstract
    • The EURopean Illicit TRAfficking Countermeasures Kit (EURITRACK) inspection system has been designed to complement X-ray scanners in the detection of explosives and other illicit materials hidden in cargo containers. The containers are interrogated by a 14-MeV tagged neutron beam at any suspect position in the X-ray image. Interrogation of a specific volume element with tagged neutrons yields information about the chemical composition of the material. Implementation and performance tests of the EURITRACK system in the Port of Rijeka in Croatia are described. Cargo container inspection results are reported and discussed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 79

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy