SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Koelbl H) "

Sökning: WFRF:(Koelbl H)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abbondanno, U, et al. (författare)
  • The data acquisition system of the neutron time-of-flight facility n_TOF at CERN
  • 2005
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 538:1-3, s. 692-702
  • Tidskriftsartikel (refereegranskat)abstract
    • The n_TOF facility at CERN has been designed for the measurement of neutron capture, fission and (n, xn) cross-sections with high accuracy. This requires a flexible and-due to the high instantaneous neutron flux-almost dead time free data acquisition system. A scalable and versatile data solution has been designed based on 8-bit flash-ADCs with sampling rates up to 2 GHz and 8 Mbyte memory buffer. The software is written in C and C++ and is running on PCs equipped with RedHat Linux.
  •  
2.
  • Gyhagen, Maria, et al. (författare)
  • Temporal trends in obstetric anal sphincter injury from the first vaginal delivery in Austria, Canada, Norway, and Sweden
  • 2021
  • Ingår i: Acta Obstetricia Et Gynecologica Scandinavica. - : Wiley. - 0001-6349 .- 1600-0412. ; 100:11, s. 1969-1976
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction Obstetric anal sphincter injuries (OASI) are severe complications that can cause considerable short- and long-term morbidity. Austria, Canada, Norway, and Sweden have similar socio-economic characteristics, and all four countries have access to national birth registers. In this study, we hypothesized that the incidence of OASI should be very similar for different obstetric scenarios in these four countries. Therefore, the aim was to compare the incidence of OASI in these four countries in primiparous women, with spontaneous or instrumental delivery (vacuum or forceps), and in women with a first vaginal birth after cesarean section (VBAC). Material and methods Aggregated data on 1 933 930 vaginally delivered primiparous women and women with VBAC were retrieved from the birth registers gathered in Austria, Canada, Norway, and Sweden. The annual rate of OASI (ICD-10 codes O70.2-O70.3) was presented as the percentage of women with a spontaneous delivery, vacuum or forceps delivery, and a VBAC during the period 2004-2016. Results The incidence of OASI varied considerably between countries and over time. Canada and Sweden had the highest rates, and Austria and Norway the lowest. In Norway, the rate of OASI decreased consistently for all types of deliveries after introducing a perineal protection program in 2004 (p < 0.001). During vacuum delivery, the incidence of OASI varied between countries from 4.1% to 15.5% across the study period. In Canada and Norway, the rate of OASI after a forceps delivery was similar in 2004 at similar to 20% and with differing trajectories to 24.3% (beta 0.49) and 6.2% (beta -1.15) (trend, all p < 0.001) in 2016. Conclusions This comparative register study suggests that there may be considerable potential for lowering the incidence of OASI. The perineal protection program implemented by Norway has been successful. Each country should critically, without prejudice, analyze their current clinical practices and rate of OASI and consider the best preventive strategy.
  •  
3.
  •  
4.
  •  
5.
  • Chapple, C. R., et al. (författare)
  • Consensus Statement of the European Urology Association and the European Urogynaecological Association on the Use of Implanted Materials for Treating Pelvic Organ Prolapse and Stress Urinary Incontinence
  • 2017
  • Ingår i: European Urology. - : Elsevier BV. - 0302-2838. ; 72:3, s. 424-431
  • Tidskriftsartikel (refereegranskat)abstract
    • Context: Surgical nonautologous meshes have been used for several decades to repair abdominal wall herniae. Implantable materials have been adopted for the treatment of female and male stress urinary incontinence (SUI) and female pelvic organ prolapse (POP). Objective: A consensus review of existing data based on published meta-analyses and reviews. Evidence acquisition: This document summarises the deliberations of a consensus group meeting convened by the European Association of Urology (EAU) and the European Urogynecological Association, to explore the current evidence relating to the use of polypropylene (PP) materials used for the treatment of SUI and POP, with reference to the 2016 EAU guidelines (European Association of Urology 2016), the European Commission's SCENIHR report on the use of surgical meshes (SCENIHR 2015), other available high-quality evidence, guidelines, and national recommendations. Evidence synthesis: Current data suggest that the use of nonautologous durable materials in surgery has well-established benefits but significant risks, which are specific to the condition and location they are used for. Various graft-related complications have been described-such as infection, chronic pain including dyspareunia, exposure in the vagina, shrinkage, erosion into other organs of xenografts, synthetic PP tapes (used in SUI), and meshes (used in POP)-which differ from the complications seen with abdominal herniae. Conclusions: When considering surgery for SUI, it is essential to evaluate the available options, which may include synthetic midurethral slings (MUSs) using PP tapes, bulking agents, colposuspension, and autologous sling surgery. The use of synthetic MUSs for surgical treatment of SUI in both male and female patients has good efficacy and acceptable morbidity. Synthetic mesh for POP should be used only in complex cases with recurrent prolapse in the same compartment and restricted to those surgeons with appropriate training who are working in multidisciplinary referral centres. Patient summary: Synthetic slings can be safely used in the surgical treatment of stress incontinence in both male and female patients. Patients need to be aware of the alternative therapy and potential risks and complications of this therapy. Synthetic mesh for treating prolapse should be used only in complex cases with recurrent prolapse in specialist referral centres.
  •  
6.
  • de Boer, T A, et al. (författare)
  • Pelvic organ prolapse and overactive bladder.
  • 2010
  • Ingår i: Neurourology and urodynamics. - : Wiley. - 1520-6777 .- 0733-2467. ; 29:1, s. 30-9
  • Forskningsöversikt (refereegranskat)abstract
    • AIMS: In this review we try to shed light on the following questions: *How frequently are symptoms of overactive bladder (OAB) and is detrusor overactivity (DO) present in patients with pelvic organ prolapse (POP) and is there a difference from women without POP? *Does the presence of OAB symptoms depend on the prolapsed compartment and/or stage of the prolapse? *What is the possible pathophysiology of OAB in POP? *Do OAB symptoms and DO change after conservative or surgical treatment of POP? METHODS: We searched on Medline and Embase for relevant studies. We only included studies in which actual data about OAB symptoms were available. All data for prolapse surgery were without the results of concomitant stress urinary incontinence (SUI) surgery. RESULTS: Community- and hospital-based studies showed that the prevalence of OAB symptoms was greater in patients with POP than without POP. No evidence was found for a relationship between the compartment or stage of the prolapse and the presence of OAB symptoms. All treatments for POP (surgery, pessaries) resulted in an improvement in OAB symptoms. It is unclear what predicts whether OAB symptoms disappear or not. When there is concomitant DO and POP, following POP surgery DO disappear in a proportion of the patients. Bladder outlet obstruction is likely to be the most important mechanism by which POP induces OAB symptoms and DO signs. However, several other mechanisms might also play a role. CONCLUSIONS: There are strong indications that there is a causal relationship between OAB and POP.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy