SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kolle Olaf) "

Sökning: WFRF:(Kolle Olaf)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Arneth, Almut, et al. (författare)
  • Spring in the boreal environment: observations on pre- and post-melt energy and CO2 fluxes in two central Siberian ecosystems
  • 2006
  • Ingår i: Boreal Environment Research: An International Interdisciplinary Journal. - 1239-6095. ; 11:4, s. 311-328
  • Tidskriftsartikel (refereegranskat)abstract
    • A range of observations points towards earlier onset of spring in northern high latitudes. However, despite the profound effects this may have on vegetation-atmosphere exchange of carbon (NEE), vegetation-atmosphere physical coupling, or the location of the tundra-taiga interface, the number of studies that investigate winter-spring transition fluxes in contrasting northern vegetation types is limited. Here, we examine spring ecosystem-atmosphere energy and carbon exchange in a Siberian pine forest and mire. Divergent surface albedo before and during snow-melt resulted in daytime net radiation (R-n) above the forest exceeding R. above the mire by up to 10 MJ m(-2). Until stomata could open, absorbed radiation by the green pine canopy caused substantial daytime sensible heat fluxes (H > 10 MJ m(-2)). H above the mire was very low, even negative (<-2 MJ M-2), during that same period. Physiological activity in both ecosystems responded rapidly to warming temperatures and snow-melt, which is essential for survival in Siberia with its very short summers. On days with above-zero temperatures, before melt. was complete, low rates of forest photosynthesis (1-2 mu mol m(-2) s(-1)) were discernible. Forest and mire NEE became negative the same day, or shortly after, photosynthesis commenced. The mire lagged by about two weeks behind the forest and regained its full carbon uptake capacity at a slower rate. Our data provide empirical evidence for the importance the timing of spring and the relative proportion of forest vs. mire has for late winter/spring boundary-layer growth, and production and surface-atmosphere mixing of trace gases. Models that seek to investigate effects of increasingly earlier spring in high latitudes must correctly account for contrasting physical and biogeochemical ecosystem-atmosphere exchange in heterogeneous landscapes.
  •  
2.
  • Feigenwinter, Christian, et al. (författare)
  • Comparison of horizontal and vertical advective CO2 fluxes at three forest sites
  • 2008
  • Ingår i: Agricultural and Forest Meteorology. - : Elsevier BV. - 1873-2240 .- 0168-1923. ; 148:1, s. 12-24
  • Tidskriftsartikel (refereegranskat)abstract
    • Extensive field measurements have been performed at three CarboEurope-Integrated Project forest sites with different topography (Renon/Ritten, Italian Alps, Italy; Wetzstein, Thuringia, Germany; Norunda, Uppland, Sweden) to evaluate the relevant terms of the carbon balance by measuring CO2 concentrations [CO2] and the wind field in a 3D multi-tower cube setup. The same experimental setup (geometry and instrumentation) and the same methodology were applied to all the three experiments. It is shown that all sites are affected by advection in different ways and strengths. Everywhere, vertical advection (F-VA) occurred only at night. During the day, F-VA disappeared because of turbulent mixing, leading to a uniform vertical profile of [CO2]. Mean F-VA was nearly zero at the hilly site (wetzstein) and at the flat site (Norunda). However, large, momentary positive or negative contributions occurred at the flat site, whereas vertical non-turbulent fluxes were generally very small at the hilly site. At the slope site (Renon), F-VA was always positive at night because of the permanently negative mean vertical wind component resulting from downslope winds. Horizontal advection also occurred mainly at night. It was positive at the slope site and negative at the flat site in the mean diurnal course. The size of the averaged non-turbulent advective fluxes was of the same order of magnitude as the turbulent flux measured by eddy-covariance technique, but the scatter was very high. This implies that it is not advisable to use directly measured quantities of the non-turbulent advective fluxes for the estimation of net ecosystem exchange (NEE) on e.g. an hourly basis. However, situations with and without advection were closely related to local or synoptic meteorological conditions. Thus, it is possible to separate advection affected NEE estimates from fluxes which are representative of the source term. However, the development of a robust correction scheme for advection requires a more detailed site-specific analysis of single events for the identification of the relevant processes. This paper presents mean characteristics of the advective CO2 fluxes in a first site-to-site comparison and evaluates the main problems for future research.
  •  
3.
  • Moderow, Uta, et al. (författare)
  • Available energy and energy balance closure at four coniferous forest sites across Europe
  • 2009
  • Ingår i: Theoretical and Applied Climatology. - : Springer Science and Business Media LLC. - 1434-4483 .- 0177-798X. ; 98:3-4, s. 397-412
  • Tidskriftsartikel (refereegranskat)abstract
    • The available energy (AE), driving the turbulent fluxes of sensible heat and latent heat at the earth surface, was estimated at four partly complex coniferous forest sites across Europe (Tharandt, Germany; Ritten/Renon, Italy; Wetzstein, Germany; Norunda, Sweden). Existing data of net radiation were used as well as storage change rates calculated from temperature and humidity measurements to finally calculate the AE of all forest sites with uncertainty bounds. Data of the advection experiments MORE II (Tharandt) and ADVEX (Renon, Wetzstein, Norunda) served as the main basis. On-site data for referencing and cross-checking of the available energy were limited. Applied cross checks for net radiation (modelling, referencing to nearby stations and ratio of net radiation to global radiation) did not reveal relevant uncertainties. Heat storage of sensible heat J (H), latent heat J (E), heat storage of biomass J (veg) and heat storage due to photosynthesis J (C) were of minor importance during day but of some importance during night, where J (veg) turned out to be the most important one. Comparisons of calculated storage terms (J (E), J (H)) at different towers of one site showed good agreement indicating that storage change calculated at a single point is representative for the whole canopy at sites with moderate heterogeneity. The uncertainty in AE was assessed on the basis of literature values and the results of the applied cross checks for net radiation. The absolute mean uncertainty of AE was estimated to be between 41 and 52 W m(-2) (10-11 W m(-2) for the sum of the storage terms J and soil heat flux G) during mid-day (approximately 12% of AE). At night, the absolute mean uncertainty of AE varied from 20 to about 30 W m(-2) (approximately 6 W m(-2) for J plus G) resulting in large relative uncertainties as AE itself is small. An inspection of the energy balance showed an improvement of closure when storage terms were included and that the imbalance cannot be attributed to the uncertainties in AE alone.
  •  
4.
  • Rebmann, Corinna, et al. (författare)
  • ICOS eddy covariance flux-station site setup : A review
  • 2018
  • Ingår i: International Agrophysics. - : Walter de Gruyter GmbH. - 0236-8722 .- 2300-8725. ; 32:4, s. 471-494
  • Forskningsöversikt (refereegranskat)abstract
    • The Integrated Carbon Observation System Research Infrastructure aims to provide long-Term, continuous observations of sources and sinks of greenhouse gases such as carbon dioxide, methane, nitrous oxide, and water vapour. At ICOS ecosystem stations, the principal technique for measurements of ecosystem-Atmosphere exchange of GHGs is the eddy-covariance technique. The establishment and setup of an eddy-covariance tower have to be carefully reasoned to ensure high quality flux measurements being representative of the investigated ecosystem and comparable to measurements at other stations. To fulfill the requirements needed for flux determination with the eddy-covariance technique, variations in GHG concentrations have to be measured at high frequency, simultaneously with the wind velocity, in order to fully capture turbulent fluctuations. This requires the use of high-frequency gas analysers and ultrasonic anemometers. In addition, to analyse flux data with respect to environmental conditions but also to enable corrections in the post-processing procedures, it is necessary to measure additional abiotic variables in close vicinity to the flux measurements. Here we describe the standards the ICOS ecosystem station network has adopted for GHG flux measurements with respect to the setup of instrumentation on towers to maximize measurement precision and accuracy while allowing for flexibility in order to observe specific ecosystem features.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy