SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kongstad O) "

Sökning: WFRF:(Kongstad O)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Blomstrand, Peter, et al. (författare)
  • Assessment of left ventricular diastolic function from mitral annulus motion, a comparison with pulsed Doppler measurements in patients with heart failure
  • 1996
  • Ingår i: Clinical Physiology. - : John Wiley & Sons. - 0144-5979 .- 1365-2281. ; 16:5, s. 483-493
  • Tidskriftsartikel (refereegranskat)abstract
    • Mitral and pulmonary venous flow velocity recordings are often used for the assessment of left ventricular diastolic function. These curves are, however, also influenced by other factors. To investigate whether mitral annulus motion carries additional information in this context, mitral annulus motion was compared to Doppler registrations of mitral and pulmonary flow velocities in 38 patients with heart failure (NYHA II-III) after myocardial infarction. Patients with an increased atrial contribution to mitral annulus motion (> 57%, n = 12) had a higher mitral late-to-early flow velocity ratio (A/E) and pulmonary systolic to diastolic filling ratio (< 0.01). Patients with atrial displacement above average for the group (≤ 5.1 mm, n = 19) had a higher mitral A/E ratio and pulmonary systolic to diastolic filling ratio than patients with a lower than average atrial component (P < 0.05). There was a significant correlation between a/T ratio and A/E ratio (r = 0.61, P < 0.001) and between pulmonary flow and transmitral flow (= 0.76, P < 0.001). We conclude that an increased atrial displacement of the mitral annulus is a frequent finding in patients with signs of left ventricular relaxation abnormality. There is a significant correlation between a/T ratio and A/E ratio but the information contained in the two indices are not identical.
  •  
2.
  • Holmqvist, Fredrik, et al. (författare)
  • A decade of catheter ablation of cardiac arrhythmias in Sweden : ablation practices and outcomes
  • 2019
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 40:10, s. 820-830
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Catheter ablation is considered the treatment of choice for many tachyarrhythmias, but convincing 'real-world' data on efficacy and safety are lacking. Using Swedish national registry data, the ablation spectrum, procedural characteristics, as well as ablation efficacy and reported adverse events are reported.Methods and Results: Consecutive patients (≥18 years of age) undergoing catheter ablation in Sweden between 01 January 2006 and 31 December 2015 were included in the study. Follow-up (repeat ablation and vital status) was collected through 31 December 2016. A total of 26 642 patients (57 ± 15 years, 62% men), undergoing a total of 34 428 ablation procedures were included in the study. In total, 4034 accessory pathway/Wolff-Parkinson-White syndrome (12%), 7358 AV-nodal re-entrant tachycardia (21%), 1813 atrial tachycardia (5.2%), 5481 typical atrial flutter (16%), 11 916 atrial fibrillation (AF, 35%), 2415 AV-nodal (7.0%), 581 premature ventricular contraction (PVC, 1.7%), and 964 ventricular tachycardia (VT) ablations (2.8%) were performed. Median follow-up time was 4.7 years (interquartile range 2.7-7.0). The spectrum of treated arrhythmias changed over time, with a gradual increase in AF, VT, and PVC ablation (P < 0.001). Decreasing procedural times and utilization of fluoroscopy with time, were seen for all arrhythmia types. The rates of repeat ablation differed between ablation types, with the highest repeat ablation seen in AF (41% within 3 years). The rate of reported adverse events was low (n = 595, 1.7%). Death in the immediate period following ablation was rare (n = 116, 0.34%).Conclusion: Catheter ablations have shifted towards more complex procedures over the past decade. Fluoroscopy time has markedly decreased and the efficacy of catheter ablation seems to improve for AF.
  •  
3.
  •  
4.
  •  
5.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy