SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Korytar P) "

Sökning: WFRF:(Korytar P)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Korytár, P, et al. (författare)
  • Separation of seventeen 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins and dibenzofurans and 12 dioxin-like polychlorinated biphenyls by comprehensive two-dimensional gas chromatography with electron-capture detection
  • 2004
  • Ingår i: Journal of Chromatography A. - Amsterdam : Elsevier. - 0021-9673 .- 1873-3778. ; 1038:1-2, s. 189-199
  • Tidskriftsartikel (refereegranskat)abstract
    • Comprehensive two-dimensional gas chromatography (GC×GC) with electron-capture detection (ECD) has been optimized for the separation of seventeen 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins and dibenzofurans and 12 dioxin-like polychlorinated biphenyls, with emphasis on the selection of the first- and second-dimension, commercially available, columns. When eight second-dimension columns were subsequently combined with a 100% methylpolysiloxane stationary phase (DB-1) in the first dimension to create orthogonal conditions, a complete separation of all congeners with different TEF values was obtained with two column combinations, DB-1 × VF-23 and DB-1 × LC-50. When other types of first-dimension columns were used (and orthogonality was partly sacrificed), a DB-XLB column combined with 007-65HT, VF-23 and LC-50 was found to provide a complete separation of all 29 priority congeners. Next, the potential of these three column combinations for real-life analysis was preliminarily studied. With a spiked and fractionated milk extract, DB-XLB × LC-50 was found to be the most powerful column combination, because of the good separation of the 29 priority congeners from each other as well as from the matrix constituents. Quantitative performance (close to three-order linearity; LODs, 30–150 fg injected; R.S.D.s, 1.5–6.5% (n=10)) was satisfactory.
  •  
6.
  • Asimakopoulou, Eleni Myrto, et al. (författare)
  • Development towards high-resolution kHz-speed rotation-free volumetric imaging
  • 2024
  • Ingår i: Optics Express. - 1094-4087. ; 32:3, s. 4413-4426
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray multi-projection imaging (XMPI) has the potential to provide rotation-free 3D movies of optically opaque samples. The absence of rotation enables superior imaging speed and preserves fragile sample dynamics by avoiding the centrifugal forces introduced by conventional rotary tomography. Here, we present our XMPI observations at the ID19 beamline (ESRF, France) of 3D dynamics in melted aluminum with 1000 frames per second and 8 µm resolution per projection using the full dynamical range of our detectors. Since XMPI is a method under development, we also provide different tests for the instrumentation of up to 3000 frames per second. As the high-brilliance of 4th generation light-sources becomes more available, XMPI is a promising technique for current and future X-ray imaging instruments.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy