SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kretschmer M.) "

Sökning: WFRF:(Kretschmer M.)

  • Resultat 1-10 av 34
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ageron, M., et al. (författare)
  • ANTARES : The first undersea neutrino telescope
  • 2011
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 656:1, s. 11-38
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES Neutrino Telescope was completed in May 2008 and is the first operational Neutrino Telescope in the Mediterranean Sea. The main purpose of the detector is to perform neutrino astronomy and the apparatus also offers facilities for marine and Earth sciences. This paper describes the design, the construction and the installation of the telescope in the deep sea, offshore from Toulon in France. An illustration of the detector performance is given. (C) 2011 Elsevier B.V. All rights reserved.
  •  
2.
  • Ageron, M., et al. (författare)
  • Studies of a full-scale mechanical prototype line for the ANTARES neutrino telescope and tests of a prototype instrument for deep-sea acoustic measurements
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 581:3, s. 695-708
  • Tidskriftsartikel (refereegranskat)abstract
    • full-scale mechanical prototype line was deployed to a depth of 2500 m to test the leak tightness of the electronics containers and the pressure-resistant properties of an electromechanical cable under evaluation for use in the ANTARES deep-sea neutrino telescope. During a month-long immersion study, line parameter data were taken using miniature autonomous data loggers and shore-based optical time domain reflectometry. Details of the mechanical prototype line, the electromechanical cable and data acquisition are presented. Data taken during the immersion study revealed deficiencies in the pressure resistance of the electromechanical cable terminations at the entry points to the electronics containers. The improvements to the termination, which have been integrated into subsequent detection lines, are discussed. The line also allowed deep-sea acoustic measurements with a prototype hydrophone system. The technical setup of this system is described, and the first results of the data analysis are presented. (c) 2007 Elsevier B.V. All rights reserved.
  •  
3.
  • Ageron, M., et al. (författare)
  • The ANTARES optical beacon system
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 578:3, s. 498-509
  • Tidskriftsartikel (refereegranskat)abstract
    • ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented. (C) 2007 Elsevier B.V. All rights reserved.
  •  
4.
  • Aguilar, J. A., et al. (författare)
  • First results of the instrumentation line for the deep-sea ANTARES neutrino telescope
  • 2006
  • Ingår i: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 26:4-5, s. 314-324
  • Tidskriftsartikel (refereegranskat)abstract
    • In 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system. as well as the calibration devices of the detector. The in situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. These results demonstrate that with the full ANTARES neutrino telescope the design angular resolution of better than 0.3 degrees can be realistically achieved.
  •  
5.
  • Aguilar, J. A., et al. (författare)
  • The data acquisition system for the ANTARES neutrino telescope
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 570:1, s. 107-116
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described. (c) 2006 Elsevier B.V. All rights reserved.
  •  
6.
  • Aguilar, J A, et al. (författare)
  • Study of large hemispherical photomultiplier tubes for the ANTARES neutrino telescope
  • 2005
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 555:1-2, s. 132-141
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES neutrino telescope, to be immersed depth in the Mediterranean Sea, will consist of a three-dimensional matrix of 900 large area photomultiplier tubes housed in pressure-resistant glass spheres. The selection of the optimal photomultiplier was a critical step for the project and required an intensive phase of tests and developments carried out in close collaboration with the main manufacturers worldwide. This paper provides an overview of the tests performed by the collaboration and describes in detail the features of the photomultiplier tube chosen for ANTARES. (c) 2005 Elsevier B.V. All rights reserved.
  •  
7.
  • Aguilar, J A, et al. (författare)
  • Transmission of light in deep sea water at the site of the ANTARES neutrino telescope
  • 2005
  • Ingår i: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 23:1, s. 131-155
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES neutrino telescope is a large photomultiplier array designed to detect neutrino-induced upward-going muons by their Cherenkov radiation. Understanding the absorption and scattering of light in the deep Mediterranean is fundamental to optimising the design and performance of the detector. This paper presents measurements of blue and UV light transmission at the ANTARES site taken between 1997 and 2000. The derived values for the scattering length and the angular distribution of particulate scattering were found to be highly correlated, and results are therefore presented in terms of an absorption length;,ab, and an effective scattering length lambda(sct)(eff). The values for blue (UV) light are found to be lambda(abs) similar or equal to 60(26) m, lambda(sct)(eff similar or equal to) 265(122) m, with significant (similar to15%) time variability. Finally, the results of ANTARES simulations showing the effect of these water properties on the anticipated performance of the detector are presented. (C) 2004 Elsevier B.V. All rights reserved.
  •  
8.
  • Ageron, M., et al. (författare)
  • Performance of the first ANTARES detector line
  • 2009
  • Ingår i: Astroparticle physics. - : Elsevier BV. - 0927-6505 .- 1873-2852. ; 31:4, s. 277-283
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper we report on the data recorded with the first Antares detector line. The line was deployed on the 14th of February 2006 and was connected to the readout 2 weeks later. Environmental data for one and a half years of running are shown. Measurements of atmospheric muons from data taken from selected runs during the first 6 months of operation are presented. Performance figures in terms of time residuals and angular resolution are given. Finally the angular distribution of atmospheric muons is presented and from this the depth profile of the muon intensity is derived. (C) 2009 Elsevier B.V. All rights reserved.
  •  
9.
  • Fuchs, A., et al. (författare)
  • Minimum Information about T Regulatory Cells: A Step toward Reproducibility and Standardization
  • 2018
  • Ingår i: Frontiers in Immunology. - : Frontiers Media SA. - 1664-3224. ; 8
  • Tidskriftsartikel (refereegranskat)abstract
    • Cellular therapies with CD4+ T regulatory cells (Tregs) hold promise of efficacious treatment for the variety of autoimmune and allergic diseases as well as posttransplant complications. Nevertheless, current manufacturing of Tregs as a cellular medicinal product varies between different laboratories, which in turn hampers precise comparisons of the results between the studies performed. While the number of clinical trials testing Tregs is already substantial, it seems to be crucial to provide some standardized characteristics of Treg products in order to minimize the problem. We have previously developed reporting guidelines called minimum information about tolerogenic antigen-presenting cells, which allows the comparison between different preparations of tolerance-inducing antigen-presenting cells. Having this experience, here we describe another minimum information about Tregs (MITREG). It is important to note that MITREG does not dictate how investigators should generate or characterize Tregs, but it does require investigators to report their Treg data in a consistent and transparent manner. We hope this will, therefore, be a useful tool facilitating standardized reporting on the manufacturing of Tregs, either for research purposes or for clinical application. This way MITREG might also be an important step toward more standardized and reproducible testing of the Tregs preparations in clinical applications.
  •  
10.
  • Liu, C, et al. (författare)
  • A DNA methylation biomarker of alcohol consumption.
  • 2018
  • Ingår i: Molecular Psychiatry. - : Springer Science and Business Media LLC. - 1359-4184 .- 1476-5578. ; 23, s. 422-433
  • Tidskriftsartikel (refereegranskat)abstract
    • The lack of reliable measures of alcohol intake is a major obstacle to the diagnosis and treatment of alcohol-related diseases. Epigenetic modifications such as DNA methylation may provide novel biomarkers of alcohol use. To examine this possibility, we performed an epigenome-wide association study of methylation of cytosine-phosphate-guanine dinucleotide (CpG) sites in relation to alcohol intake in 13 population-based cohorts (ntotal=13 317; 54% women; mean age across cohorts 42-76 years) using whole blood (9643 European and 2423 African ancestries) or monocyte-derived DNA (588 European, 263 African and 400 Hispanic ancestry) samples. We performed meta-analysis and variable selection in whole-blood samples of people of European ancestry (n=6926) and identified 144 CpGs that provided substantial discrimination (area under the curve=0.90-0.99) for current heavy alcohol intake (⩾42 g per day in men and ⩾28 g per day in women) in four replication cohorts. The ancestry-stratified meta-analysis in whole blood identified 328 (9643 European ancestry samples) and 165 (2423 African ancestry samples) alcohol-related CpGs at Bonferroni-adjusted P<1 × 10(-7). Analysis of the monocyte-derived DNA (n=1251) identified 62 alcohol-related CpGs at P<1 × 10(-7). In whole-blood samples of people of European ancestry, we detected differential methylation in two neurotransmitter receptor genes, the γ-Aminobutyric acid-A receptor delta and γ-aminobutyric acid B receptor subunit 1; their differential methylation was associated with expression levels of a number of genes involved in immune function. In conclusion, we have identified a robust alcohol-related DNA methylation signature and shown the potential utility of DNA methylation as a clinically useful diagnostic test to detect current heavy alcohol consumption.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 34
Typ av publikation
tidskriftsartikel (31)
konferensbidrag (2)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (33)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Kretschmer, M. (11)
Ratynskaia, Svetlana ... (9)
Kooijman, P. (8)
Aguilar, J. A. (8)
Kappes, A. (8)
Montaruli, T. (8)
visa fler...
Anton, G. (8)
Katz, U. (8)
Brunner, J. (8)
Albert, A. (8)
Becherini, Yvonne (8)
Carr, J. (8)
Zaborov, D. (8)
Giacomelli, G. (8)
Margiotta, A. (8)
Popa, V. (8)
Spurio, M. (8)
Anghinolfi, M. (8)
Anvar, S. (8)
Aubert, J-J. (8)
Basa, S. (8)
Bertin, V. (8)
Bouwhuis, M. C. (8)
Circella, M. (8)
Coyle, P. (8)
Deschamps, A. (8)
Hallewell, G. (8)
Hello, Y. (8)
Hernandez-Rey, J. J. (8)
de Jong, M. (8)
Kouchner, A. (8)
Lo Presti, D. (8)
Loucatos, S. (8)
Louis, F. (8)
Marcelin, M. (8)
Moscoso, L. (8)
Pradier, T. (8)
Racca, C. (8)
Russo, G. V. (8)
Schuller, J-P. (8)
Vernin, P. (8)
de Wolf, E. (8)
Zuniga, J. (8)
Druillole, F. (8)
Kretschmer, W. (8)
Lamare, P. (8)
Le Provost, H. (8)
Mazure, A. (8)
Payre, P. (8)
Ruppi, M. (8)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (9)
Linnéuniversitetet (8)
Karolinska Institutet (7)
Uppsala universitet (6)
Göteborgs universitet (2)
Stockholms universitet (2)
visa fler...
Lunds universitet (1)
Chalmers tekniska högskola (1)
Karlstads universitet (1)
visa färre...
Språk
Engelska (34)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (10)
Medicin och hälsovetenskap (3)
Samhällsvetenskap (2)
Teknik (1)
Lantbruksvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy