SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kurano M.) "

Sökning: WFRF:(Kurano M.)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kodaira, S., et al. (författare)
  • On the use of CR-39 PNTD with AFM analysis in measuring proton-induced target fragmentation particles
  • 2015
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms. - : Elsevier BV. - 0168-583X. ; 349, s. 163-168
  • Tidskriftsartikel (refereegranskat)abstract
    • In addition to energy loss by ionization process, protons of energy >similar to 50 MeV, such as those used in proton radiotherapy, can undergo nuclear interactions with nuclei of Z > 1, resulting in the production, of short range (<20 gm), high-LET (linear energy transfer) target fragment particles. One of the few methods to detect these short-range particles is by means of CR-39 plastic nuclear track detector (PNTD) analyzed with an atomic force microscope (AFM). However, due to the LET-dependent angular sensitivity of CR-39 PNTD, multiple detectors exposed at a range of incident angles to the primary proton beam, must be analyzed in order to accurately determine the LET spectrum, absorbed dose and dose equivalent. The LET spectrum of 160 MeV proton-induced secondary particles was experimentally measured with CR-39 PNTDs, which were exposed at six different incident angles to take into account the intrinsic sensitivity of the critical angle for track registration. The irradiated detectors were chemically processed to remove a 1 gm thick volume of CR-39 PNTD. The measured LET range of short range tracks was from 15 key/mu m up to 1.5 MeV/mu m. The absorbed dose contribution (D-s/D-p) from secondary particles to primary proton dose was similar to 1%, while the dose equivalent contribution (H-s/D-p) was found to be similar to 20%. Analysis of CR-39 PNTD by AFM yielded similar to 60% higher value for absorbed dose compared to standard optical microscopy analysis.
  •  
2.
  • Ota, S., et al. (författare)
  • Charge resolution of CR-39 plastic nuclear track detectors for intermediate energy heavy ions
  • 2011
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms. - : Elsevier BV. - 0168-583X. ; 269:12, s. 1382-1388
  • Tidskriftsartikel (refereegranskat)abstract
    • The charge resolution (delta Z) for heavy ions (nuclear charge: Z = 60 mu m (30 h etching), saturation occurs and there is no further improvement in delta Z. Analysis of the correlations between projectile Z, energy, detector response, and fluctuation of the response make it possible to develop a model to predict the delta Z for projectiles of given Z and energy. The predicted and measured values of delta Z show good agreement within 10%. We conclude that 4
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy