SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lalanne G.) "

Sökning: WFRF:(Lalanne G.)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Girard-Alcindor, V., et al. (författare)
  • New narrow resonances observed in the unbound nucleus F 15
  • 2022
  • Ingår i: Physical Review C. - : American Physical Society (APS). - 2469-9985 .- 2469-9993. ; 105:5
  • Tidskriftsartikel (refereegranskat)abstract
    • The structure of the unbound F15 nucleus is investigated using the inverse kinematics resonant scattering of a radioactive O14 beam impinging on a CH2 target. The analysis of H1(O14,p)O14 and H1(O14,2p)N13 reactions allowed the confirmation of the previously observed narrow 1/2- resonance, near the two-proton decay threshold, and the identification of two new narrow 5/2- and 3/2- resonances. The newly observed levels decay by 1p emission to the ground of O14, and by sequential 2p emission to the ground state of N13 via the 1- resonance of O14. Gamow shell model (GSM) analysis of the experimental data suggests that the wave functions of the 5/2- and 3/2- resonances may be collectivized by the continuum coupling to nearby 2p- and 1p-decay channels. The observed excitation function H1(O14,p)O14 and resonance spectrum in F15 are well reproduced in the unified framework of the GSM.
  •  
2.
  • Nichols, M., et al. (författare)
  • Investigating radioactive negative ion production via double electron capture
  • 2023
  • Ingår i: Nuclear Instruments & Methods in Physics Research Section B-Beam Interactions with Materials and Atoms. - 0168-583X. ; 541, s. 264-267
  • Tidskriftsartikel (refereegranskat)abstract
    • The relative cross sections for radioactive negative ion production via double electron capture have been measured for collisions between a 40 keV projectile beam of uranium-238 and potassium vapor. This was performed at the collinear resonance ionization spectroscopy (CRIS) experiment at CERN-ISOLDE and is a step towards measuring the electron affinities (EAs) of elements that cannot be efficiently produced in negative ion sources at radioactive ion beam (RIB) facilities. This includes short-lived radioactive isotopes that have low production quantities and heavy and superheavy elements that systematically have smaller EAs than work functions of available ion source materials. Negative ions are particularly sensitive to electron-electron correlation effects, which make such studies ideal for benchmarking atomic structure models that go beyond the independent particle model. While the EAs of most light elements have been measured, experimental investigations on heavier elements, namely the actinides, remain scarce due to their radioactive nature and production difficulty. By developing negative ion production by charge exchange, we aim to make these studies feasible at RIB facilities.
  •  
3.
  • Urquiza-González, M., et al. (författare)
  • Benchmark evaluation for a single frequency continuous wave OPO seeded pulsed dye amplifier for high-resolution laser spectroscopy
  • 2023
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. - 0277-786X .- 1996-756X. - 9781510659032
  • Konferensbidrag (refereegranskat)abstract
    • The study of the atomic spectrum via resonant laser excitation provides access to underlying effects caused by the nuclear structure, which is of special interest in short-lived radioisotopes produced at Isotope Separator On-Line (ISOL) facilities. Current implementations of resonant laser ionization techniques often limit the extraction of the nuclear observables due to the low spectral resolution of the pulsed laser systems deployed. Several high-resolution spectroscopy techniques demand spectral widths in the order of hundreds of MHz and below. A proven solution to reduce this linewidth is the pulsed amplification of a narrow-band continuous wave (cw) laser. This work presents the demonstration of a pulsed dye amplifier seeded by a commercially available cw Optical Parametric Oscillator (OPO). The performance of this system was compared with competing setups using a cw dye laser seed source as well as a frequency mixing technique using a combination of an injection-locked titanium:sapphire (Ti:Sa) and a Nd:YVO4 laser. Spectral bandwidths of the systems were measured using a high finesse Fabry-Perot Interferometer, resulting in comparable optical linewidths between 140 to 156 MHz at a wavelength of 328 nm for the different laser setups. Suitability for on-line experiments was validated by performing high-resolution spectroscopy of radioactive silver isotopes in the Collinear Resonance Ionization Spectroscopy (CRIS) experiment at the Isotope Separator On-Line Device (ISOLDE), at the European Organization for Nuclear Research (CERN). The quality of the hyperfine spectra was similar for the dye and the OPO seed and the deduced hyperfine splitting was in good agreement with literature, while the frequency mixing technique exhibited less precise results attributed to the frequency instabilities and mode-hops of the single-mode Nd:YVO4 laser.
  •  
4.
  • Udrescu, S. M., et al. (författare)
  • Precision spectroscopy and laser-cooling scheme of a radium-containing molecule
  • 2024
  • Ingår i: NATURE PHYSICS. - 1745-2473 .- 1745-2481.
  • Tidskriftsartikel (refereegranskat)abstract
    • Molecules containing heavy radioactive nuclei are predicted to be extremely sensitive to violations of the fundamental symmetries of nature. The nuclear octupole deformation of certain radium isotopes massively boosts the sensitivity of radium monofluoride molecules to symmetry-violating nuclear properties. Moreover, these molecules are predicted to be laser coolable. Here we report measurements of the rovibronic structure of radium monofluoride molecules, which allow the determination of their laser cooling scheme. We demonstrate an improvement in resolution of more than two orders of magnitude compared to the state of the art. Our developments allowed measurements of minuscule amounts of hot molecules, with only a few hundred per second produced in a particular rotational state. The combined precision and sensitivity achieved in this work offer opportunities for studies of radioactive molecules of interest in fundamental physics, chemistry and astrophysics. Measurements of the rovibronic structure of radium monofluoride molecules allow the identification of a laser cooling scheme. This will enable precise tests of fundamental physics, such as searches for parity or time-reversal symmetry violation.
  •  
5.
  • Athanasakis-Kaklamanakisa, Michail, et al. (författare)
  • Voltage scanning and technical upgrades at the Collinear Resonance Ionization Spectroscopy experiment
  • 2023
  • Ingår i: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - 0168-583X .- 1872-9584. ; 541, s. 86-89
  • Tidskriftsartikel (refereegranskat)abstract
    • To optimize the performance of the Collinear Resonance Ionization Spectroscopy (CRIS) experiment at CERN-ISOLDE, technical upgrades are continuously introduced, aiming to enhance its sensitivity, precision, stability, and efficiency. Recently, a voltage-scanning setup was developed and commissioned at CRIS, which improved the scanning speed by a factor of three as compared to the current laser-frequency scanning approach. This leads to faster measurements of the hyperfine structure for systems with high yields (more than a few thousand ions per second). Additionally, several beamline sections have been redesigned and manufactured, including a new field-ionization unit, an electrostatic bend with a larger deflection angle, and improved ion optics. The beamline upgrades are expected to yield an improvement of at least a factor of 5 in the signal-to-noise ratio by avoiding the use of high-power lasers (which yield non-resonantly produced ions) and providing time-of-flight separation between the resonant ions and the collisional background.
  •  
6.
  • Scherbaum, W. A., et al. (författare)
  • Efficacy and tolerability of vildagliptin in drug-naive patients with type 2 diabetes and mild hyperglycaemia
  • 2008
  • Ingår i: Diabetes, Obesity and Metabolism. - : Wiley. - 1462-8902 .- 1463-1326. ; 10:8, s. 675-682
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: This study was conducted to assess efficacy and tolerability of vildagliptin in drug-naive patients with type 2 diabetes and mild hyperglycaemia. Methods: Multicentre, double-blind, randomized, placebo-controlled, parallel-group study of 52-week treatment with vildagliptin (50 mg q.d.) in 306 drug-naive patients with type 2 diabetes (A1C = 6.2-7.5%). A1C, fasting plasma glucose (FPG) and measures of prandial glucose control and beta-cell function determined during standard meal tests were assessed. Results: Baseline A1C and FPG averaged 6.7% and 7.1 mmol/l, respectively, in patients randomized to vildagliptin (n = 156) and 6.8% and 7.2 mmol/l in those randomized to placebo (n = 150). A1C decreased modestly in vildagliptin-treated patients (Delta = -0.2 +/- 0.1%) and increased in patients receiving placebo (Delta = 0.1 +/- 0.1%). The between-group difference (vildagliptin - placebo) in adjusted mean change (AM Delta) in A1C was -0.3 +/- 0.1% (p < 0.001). FPG increased in patients receiving placebo (Delta = 0.5 +/- 0.1 mmol/l) and to a significantly lesser extent in vildagliptin-treated patients (between-group difference in AM Delta FPG = -0.4 +/- 0.2 mmol/l, p = 0.032). Relative to placebo, 2-h postprandial glucose (PPG) decreased (-0.9 +/- 0.4 mmol/l, p = 0.012), and insulin secretory rate (ISR) relative to glucose [ISR area under the curve (AUC)(0-2) (h)/glucose AUC(0-2) (h)] increased (+5.0 +/- 1.2 pmol/min/m(2)/mM, p < 0.001). Mean body weight decreased by 0.5 +/- 0.3 kg in vildagliptin-treated patients and by 0.2 +/- 0.3 kg in patients receiving placebo. The side-effect profile of vildagliptin was similar to that of placebo, and one hypoglycaemic episode occurred in one patient receiving placebo. Conclusions: In drug-naive patients with mild hyperglycaemia, relative to placebo, 52-week treatment with vildagliptin 50 mg q.d. significantly decreases A1C, FPG and PPG and improves beta-cell function without weight gain or hypoglycaemia.
  •  
7.
  • Scherbaum, W. A., et al. (författare)
  • Evidence that vildagliptin attenuates deterioration of glycaemic control during 2-year treatment of patients with type 2 diabetes and mild hyperglycaemia
  • 2008
  • Ingår i: Diabetes, Obesity and Metabolism. - : Wiley. - 1462-8902 .- 1463-1326. ; 10:11, s. 1114-1124
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: To assess the 2-year efficacy and tolerability of vildagliptin (50 mg once daily) in patients with type 2 diabetes (T2DM) and mild hyperglycaemia. Methods: This was a multicentre, randomized, double-blind, placebo-controlled trial comprising a 52-week core study with a 4-week, active treatment-free washout followed by a 52-week extension study with another washout period conducted in 131 drug-naive patients with T2DM and mild hyperglycaemia [glycosylated haemoglobin ( HbA(1c)) 6.2-7.2%]. All patients received lifestyle counselling at each study visit. Efficacy and tolerability were assessed during visits at weeks 0 (core study baseline), 4, 8, 12, 16, 24, 32, 40 and 52 of active treatment; at week 56 (i.e. after the first washout period); at weeks 68, 80, 96 and 108 and at week 112 (i.e. after the second washout period). Standard meal tests were also performed at weeks 0, 24, 52, 56, 80, 108 and 112 to assess postprandial glycaemia and beta-cell function, which was quantified by glucose area under the curve (AUC(0-2) (h))/insulin secretory rate (ISR) AUC(0-2) (h) (ISR/G). Changes from baseline and between-treatment differences (placebo-adjusted changes from baseline during vildagliptin treatment) were analysed by ANCOVA. Results: The placebo-adjusted change from week 0 in HbA(1c) was -0.3 +/- 0.1% after 1 year of vildagliptin treatment (p < 0.001) and -0.5 +/- 0.2% after 2 years (p = 0.008). The placebo-adjusted change from core study baseline in fasting plasma glucose, in glucose AUC(0-2) (h) and in the beta-cell function parameter, ISR/G, tended to be greater after 2 years than after 1 year of treatment with vildagliptin. Even after a 4-week washout, the placebo-adjusted change from week 0 to week 112 in ISR/G was 3.2 +/- 1.6 pmol/min/m(2)/mM (p = 0.058) and the placebo-adjusted difference in the change from week 0 to week 112 in HbA(1c) was -0.3 +/- 0.1% (p = 0.051). The incidences of adverse events (AEs), serious AEs and discontinuations because of AEs were similar in the two treatment groups, and hypoglycaemic episodes were reported by no patient receiving vildagliptin and by two patients receiving placebo. Conclusions: In drug-naive patients with mild hyperglycaemia, 2-year treatment with vildagliptin 50 mg once daily attenuated the progressive loss of glycaemic control seen in patients receiving only lifestyle counselling ( and placebo). This appears to be because of a corresponding attenuation of the deterioration of beta-cell function as assessed by ISR/G.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy