SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lennborn Ulrica) "

Sökning: WFRF:(Lennborn Ulrica)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Johansson, Anna, et al. (författare)
  • A non-fatal intoxication and seven deaths involving the dissociative drug 3-MeO-PCP
  • 2017
  • Ingår i: Forensic Science International. - : ELSEVIER IRELAND LTD. - 0379-0738 .- 1872-6283. ; 275, s. 76-82
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: 3-methoxyphencyclidine (3-MeO-PCP) appeared on the illicit drug market in 2011 and is an analogue of phencyclidine, which exhibits anesthetic, analgesic and hallucinogenic properties. In this paper, we report data from a non-fatal intoxication and seven deaths involving 3-MeO-PCP in Sweden during the period March 2014 until June 2016. Case descriptions: The non-fatal intoxication case, a 19-year-old male with drug problems and a medical history of depression, was found awake but tachycardic, hypertensive, tachypnoeic and catatonic at home. After being hospitalized, his condition worsened as he developed a fever and lactic acidosis concomitant with psychomotor agitation and hallucinations. After 22 h of intensive care, the patient had made a complete recovery. During his hospitalization, a total of four blood samples were collected at different time points. The seven autopsy cases, six males and one female, were all in their twenties to thirties with psychiatric problems and/or an ongoing drug abuse. Methods: 3-MeO-PCP was identified with liquid chromatography (LC)/time-of-flight technology and quantified using LC-tandem mass spectrometry. Results: In the clinical case, the concentration of 3-MeO-PCP was 0.14 mu g/g at admission, 0.08 mu g/g 2.5 h after admission, 0.06 mu g/g 5 h after admission and 0.04 mu g/g 17 h after admission. The half-life of 3-MeO-PCP was estimated to 11 h. In the autopsy cases, femoral blood concentrations ranged from 0.05 mu g/g to 0.38 mu g/g. 3-MeO-PCP was the sole finding in the case with the highest concentration and the cause of death was established as intoxication with 3-MeO-PCP. In the remaining six autopsy cases, other medications and drugs of abuse were present as well. Conclusion: Despite being scheduled in January 2015, 3-MeO-PCP continues to be abused in Sweden. Exposure to 3-MeO-PCP may cause severe adverse events and even death, especially if the user does not receive life-supporting treatment.
  •  
2.
  • Johansson, Anna, et al. (författare)
  • Quantitation of seven sedative and analgesic drugs in whole blood from intensive care patients using liquid chromatography mass spectrometry
  • 2021
  • Ingår i: TOXICOLOGIE ANALYTIQUE ET CLINIQUE. - : Elsevier. - 2352-0078 .- 2352-0086. ; 33:4, s. 327-337
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantification of clonidine, dexmedetomidine, fentanyl, ketamine, ketobemidone, midazolam and morphine in whole blood. These are drugs predominately used in intensive care units (ICUs) but they are also encountered in forensic investigations. The analytes were recovered from 0.25 g of blood by protein precipitation with a mixture of acetonitrile and ethanol. Separation was performed on a BEH phenyl column. Mobile phases consisted of 0.05% formic acid in 10 mM ammonium formate and 0.05% formic acid in methanol, respectively, and the flow rate was 600 mu L/min. The mass spectrometer was operated in positive electrospray ionization mode with multiple reaction monitoring. Validation included selectivity, qualitative matrix effects, calibration model, limit of detection, lower limit of quantification, within- and between-day accuracy and precision, process efficiency, dilution integrity, carry over and stability. Selectivity was high and no ion suppression or enhancementwas observed in the areas were the analytes eluted. Calibration curves were linear over arange of 0.25-50 ng/g for dexmedetomidine, 0.05-50 ng/g for fentanyl and 5.0-500 ng/g formorphine and quadratic over a range of 0.5-50 ng/g for clonidine, 50-5000 ng/g for ketamine, 5.0-500 ng/g for ketobemidone and midazolam. The method showed acceptable within- and betweenday accuracies and precisions. All analytes were stable in whole blood for three weeksat 4. C. Concentrations in patient samples ranged between 42-760 ng/g for midazolam (n = 15), 0.3-1.5 ng/g for dexmedetomidine (n = 13), 0.6-6.4 ng/g for clonidine (n = 13), 8-62 ng/g for morphine (n = 16), 5-19 ng/g for ketobemidone (n = 5), 0.07-3.1 ng/g for fentanyl (n = 43), and 562000 ng/g for ketamine (n = 10). We conclude that the method was successfully validatedand applied to ante-mortem and post-mortem blood samples from critically ill adult patientsin a general ICU.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy