SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Leone Nicola) "

Sökning: WFRF:(Leone Nicola)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Algaba, Juan-Carlos, et al. (författare)
  • Broadband Multi-wavelength Properties of M87 during the 2017 Event Horizon Telescope Campaign
  • 2021
  • Ingår i: Astrophysical Journal Letters. - : American Astronomical Society. - 2041-8213 .- 2041-8205. ; 911:1
  • Forskningsöversikt (refereegranskat)abstract
    • In 2017, the Event Horizon Telescope (EHT) Collaboration succeeded in capturing the first direct image of the center of the M87 galaxy. The asymmetric ring morphology and size are consistent with theoretical expectations for a weakly accreting supermassive black hole of mass ∼6.5 × 109 M o˙. The EHTC also partnered with several international facilities in space and on the ground, to arrange an extensive, quasi-simultaneous multi-wavelength campaign. This Letter presents the results and analysis of this campaign, as well as the multi-wavelength data as a legacy data repository. We captured M87 in a historically low state, and the core flux dominates over HST-1 at high energies, making it possible to combine core flux constraints with the more spatially precise very long baseline interferometry data. We present the most complete simultaneous multi-wavelength spectrum of the active nucleus to date, and discuss the complexity and caveats of combining data from different spatial scales into one broadband spectrum. We apply two heuristic, isotropic leptonic single-zone models to provide insight into the basic source properties, but conclude that a structured jet is necessary to explain M87's spectrum. We can exclude that the simultaneous γ-ray emission is produced via inverse Compton emission in the same region producing the EHT mm-band emission, and further conclude that the γ-rays can only be produced in the inner jets (inward of HST-1) if there are strongly particle-dominated regions. Direct synchrotron emission from accelerated protons and secondaries cannot yet be excluded.
  •  
2.
  • Asciutto, Giuseppe, et al. (författare)
  • Intravascular ultrasound in the detection of bridging stent graft instability during fenestrated and branched endovascular aneurysm repair procedures : a multicentre study on 274 target vessels
  • 2024
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier. - 1078-5884 .- 1532-2165. ; 67:1, s. 99-104
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The use of intravascular ultrasound (IVUS) reduces contrast medium use and radiation exposure during conventional endovascular aneurysm repair (EVAR). The aim of this study was to evaluate the safety and efficacy of IVUS in detecting bridging stent graft (bSG) instability during fenestrated and branched EVAR (F/B-EVAR).Methods: This was a prospective observational multicentre study. The following outcomes were evaluated: (1) technical success of the IVUS in each bSG, (2) IVUS findings compared with intra-operative angiography, (3) incidence of post-operative computed tomography angiography (CTA) findings not detected with IVUS, and (4) absence of IVUS related adverse events. Target visceral vessel (TVV) instability was defined as any branch or fenestration issues requiring an additional manoeuvre or re-intervention. Any IVUS assessment that detected stenosis, kinking, or any geometric TVV issue was considered to be branch instability. All procedures were performed in ad hoc hybrid rooms.Results: Eighty patients (69% males; median age 72 years; interquartile range 59, 77 years) from four aortic centres treated with F/B-EVAR between January 2019 and September 2021 were included: 70 BEVAR (21 off the shelf; 49 custom made), eight FEVAR (custom made), and two F/B-EVAR (custom made), for a total of 300 potential TVVs. Two TVVs (0.7%) were left unstented and excluded from the analysis. The TVVs could not be accessed with the IVUS catheter in seven cases (2.3%). Furthermore, 17 (5.7%) TVVs could not be examined due to a malfunction of the IVUS catheter. The technical success of the IVUS assessment was 91.9% (274/298), with no IVUS related adverse events. Seven TVVs (2.5%) showed signs of bSG instability by means of IVUS, leading to immediate revisions. The first post-operative CTA at least 30 days after the index procedure was available in 268 of the 274 TVVs originally assessed by IVUS. In seven of the 268 TVVs (2.6%) a re-intervention became necessary due to bSG instability.Conclusion: This study suggests that IVUS is a safe and potentially valuable adjunctive imaging technology for intra-operative detection of TVV instability. Further long term investigations on larger cohorts are required to validate these promising results and to compare IVUS with alternative technologies in terms of efficiency, radiation exposure, procedure time, and costs.
  •  
3.
  • Cancelloni, Virginia, et al. (författare)
  • Reperfusion therapies in patients with acute ischaemic stroke and atrial fibrillation: data on safety and effectiveness from a multi-centre cohort study
  • 2024
  • Ingår i: NEUROLOGICAL SCIENCES. - 1590-1874 .- 1590-3478.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Intravenous thrombolysis (IVT) and/or endovascular therapy (EVT) are currently considered best practices in acute stroke patients. Data regarding the efficacy and safety of reperfusion therapies in patients with atrial fibrillation (AF) are conflicting as regards haemorrhagic transformation, mortality, and functional outcome. This study sought to investigate for any differences, in terms of safety and effectiveness, between AF patients with acute ischaemic stroke (AIS) treated and untreated with reperfusion therapies.Methods Data from two multicenter cohort studies (RAF and RAF-NOACs) on consecutive patients with AF and AIS were analyzed to compare patients treated and not treated with reperfusion therapies (IVT and/or EVT). Multivariable logistic regression analysis was performed to identify independent predictors for outcome events: 90-day good functional outcome and mortality. A propensity score matching (PSM) analysis compared treated and untreated patients.Results Overall, 441 (25.4%) were included in the reperfusion-treated group and 1,295 (74.6%) in the untreated group. The multivariable model suggested that reperfusion therapies were significantly associated with good functional outcome. Rates of mortality and disability were higher in patients not treated, especially in the case of higher NIHSS scores. In the PSM comparison, 173/250 patients (69.2%) who had received reperfusion therapies had good functional outcome at 90 days, compared to 146/250 (58.4%) untreated patients (p = 0.009, OR: 1.60, 95% CI:1.11-2.31).Conclusions Patients with AF and AIS treated with reperfusion therapies had a significantly higher rate of good functional outcome and lower rates of mortality compared to those patients with AF and AIS who had undergone conservative treatment.
  •  
4.
  • Karelis, Angelos, et al. (författare)
  • Iliac Branch Devices in the Repair of Ruptured Aorto-iliac Aneurysms: A Multicenter Study
  • 2023
  • Ingår i: Journal of Endovascular Therapy. - : SAGE PUBLICATIONS INC. - 1526-6028 .- 1545-1550.
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To evaluate the outcomes of preserving the internal iliac artery (IIA) with iliac branched devices (IBDs) during acute endovascular repair of ruptured aortoiliac aneurysms. Material and Methods: This is a multicenter retrospective review of all consecutive patients undergoing acute endovascular repair of ruptured aortoiliac aneurysm with an IBD at 8 aortic centers between December 2012 and June 2020. A control group was used where the IIA was intentionally occluded from the same study period. The main outcome measures were 30-day mortality, major adverse events, technical success, and clinical success. Secondary outcomes were buttock claudication, primary patency, primary-assisted and secondary patency of the IBD, occurrence of endoleak types I/III, and reintervention. Values are presented as numbers and percentages or interquartile range in parenthesis. Results: Forty-eight patients were included in the study: 24 with IBD and 24 with IIA occlusion. There was no difference in demographics, cardiovascular risk factors, and aneurysm extent. Twenty (83%) of them were hemodynamically stable during the procedure as opposed to 14 (58%, p=.23) with the IIA occlusion. Technical success was achieved in all cases with a procedure time of 180 (133-254) minutes, 45 (23-65) of which were from IBD. There were 2 (8%) deaths during the first 30 days and 2 (8%) major complications unrelated to the IBD, whereas in the IIA occlusion, the figures were 10 (42%) and 7 (29%), respectively. No patient in the IBD group developed buttock claudication compared to 8 (57%, p<.0001) in the IIA occlusion group; 1 (4%) patient developed bowel ischemia on both groups, with 1 in the IIA occlusion group needing resection. The median follow-up duration was 17 months (interquartile range 2-39) for the IBD group, with a primary patency of 60 +/- 14% at 3 years that went up to 92 +/- 8% with reinterventions (8 reinterventions in 6 patients). When the first 90 days were disregarded, there were no differences in survival between the groups. Conclusion: IBD is a valid alternative for maintaining the pelvic circulation for endovascular aortic aneurysm repair of ruptured aortoiliac aneurysms. The technical success and midterm outcomes are very satisfactory but require patient selection particularly regarding hemodynamic stability. The reintervention rate is considerable, mandating continuous follow-up. Clinical Impact This multicenter study demonstrates that ruptured aortoiliac aneurysms do not necessarily require mandatory occlusion of hypogastric arteries. Iliac branch devices are shown to be a valid alternative in highly selected cases, with good midterm results, even if reinterventions are required in a significant proportion of patients.
  •  
5.
  • Sartelli, Massimo, et al. (författare)
  • Ten golden rules for optimal antibiotic use in hospital settings: the WARNING call to action
  • 2023
  • Ingår i: WORLD JOURNAL OF EMERGENCY SURGERY. - 1749-7922. ; 18:1
  • Forskningsöversikt (refereegranskat)abstract
    • Antibiotics are recognized widely for their benefits when used appropriately. However, they are often used inappropriately despite the importance of responsible use within good clinical practice. Effective antibiotic treatment is an essential component of universal healthcare, and it is a global responsibility to ensure appropriate use. Currently, pharmaceutical companies have little incentive to develop new antibiotics due to scientific, regulatory, and financial barriers, further emphasizing the importance of appropriate antibiotic use. To address this issue, the Global Alliance for Infections in Surgery established an international multidisciplinary task force of 295 experts from 115 countries with different backgrounds. The task force developed a position statement called WARNING (Worldwide Antimicrobial Resistance National/International Network Group) aimed at raising awareness of antimicrobial resistance and improving antibiotic prescribing practices worldwide. The statement outlined is 10 axioms, or "golden rules," for the appropriate use of antibiotics that all healthcare workers should consistently adhere in clinical practice.
  •  
6.
  • Tsilimparis, Nikolaos, et al. (författare)
  • Transatlantic multicenter study on the use of a modified preloaded delivery system for fenestrated endovascular aortic repair
  • 2023
  • Ingår i: Journal of Vascular Surgery. - 0741-5214. ; 78:4, s. 3-873
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Analyze the outcomes of endovascular complex abdominal and thoracoabdominal aortic aneurysm repair using the Cook fenestrated device with the modified preloaded delivery system (MPDS) with a biport handle and preloaded catheters. Methods: A multicenter retrospective single arm cohort study was performed, including all consecutive patients with complex abdominal aortic aneurysm repair and thoracoabdominal aortic aneurysms treated with the MPDS fenestrated device (Cook Medical). Patient clinical characteristics, anatomy, and indications for device use were collected. Outcomes, classified according to the Society for Vascular Surgery reporting standards, were collected at discharge, 30 days, 6 months, and annually thereafter. Results: Overall, 712 patients (median age, 73 years; interquartile range [IQR], 68-78 years; 83% male) from 16 centers in Europe and the United States treated electively were included: 35.4% (n = 252) presented with thoracoabdominal aortic aneurysms and 64.6% (n = 460) with complex abdominal aortic aneurysm repair. Overall, 2755 target vessels were included (mean, 3.9 per patient). Of these, 1628 were incorporated via ipsilateral preloads using the MPDS (1440 accessed from the biport handle and 188 from above). The mean size of the contralateral femoral sheath during target vessel catheterization was 15F ± 4, and in 41 patients (6.7%) the sheath size was ≤8F. Technical success was 96.1%. Median procedural time was 209 minutes (IQR, 161-270 minutes), contrast volume was 100 mL (IQR, 70-150mL), fluoroscopy time was 63.9 minutes (IQR, 49.7-80.4 minutes) and median cumulative air kerma radiation dose was 2630 mGy (IQR, 838-5251 mGy). Thirty-day mortality was 4.8% (n = 34). Access complications occurred in 6.8% (n = 48) and 30-day reintervention in 7% (n = 50; 18 branch related). Follow-up of >30 days was available for 628 patients (88%), with a median follow-up of 19 months (IQR, 8-39 months). Branch-related endoleaks (type Ic/IIIc) were observed in 15 patients (2.6%) and aneurysm growth of >5 mm was observed in 54 (9.5%). Freedom from reintervention at 12 and 24 months was 87.1% (standard error [SE],1.5%) and 79.2% (SE, 2.0%), respectively. Overall target vessel patency at 12 and 24 months was 98.6% (SE, 0.3%) and 96.8% (SE, 0.4%), respectively, and was 97.9% (SE, 0.4%) and 95.3% (SE, 0.8%) for arteries stented from below using the MPDS, respectively. Conclusions: The MPDS is safe and effective. Overall benefits include a decrease in contralateral sheath size in the treatment of complex anatomies with favorable results.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy