SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Lexcen D. R.) "

Search: WFRF:(Lexcen D. R.)

  • Result 1-2 of 2
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Wilkoff, B. L., et al. (author)
  • Impact of Cardiac Implantable Electronic Device Infection A Clinical and Economic Analysis of the WRAP-IT Trial
  • 2020
  • In: Circulation-Arrhythmia and Electrophysiology. - : Ovid Technologies (Wolters Kluwer Health). - 1941-3149 .- 1941-3084. ; 13:5
  • Journal article (peer-reviewed)abstract
    • Background: Current understanding of the impact of cardiac implantable electronic device (CIED) infection is based on retrospective analyses from medical records or administrative claims data. The WRAP-IT (Worldwide Randomized Antibiotic Envelope Infection Prevention Trial) offers an opportunity to evaluate the clinical and economic impacts of CIED infection from the hospital, payer, and patient perspectives in the US healthcare system. Methods: This was a prespecified, as-treated analysis evaluating outcomes related to major CIED infections: mortality, quality of life, disruption of CIED therapy, healthcare utilization, and costs. Payer costs were assigned using medicare fee for service national payments, while medicare advantage, hospital, and patient costs were derived from similar hospital admissions in administrative datasets. Results: Major CIED infection was associated with increased all-cause mortality (12-month risk-adjusted hazard ratio, 3.41 [95% CI, 1.81-6.41]; P<0.001), an effect that sustained beyond 12 months (hazard ratio through all follow-up, 2.30 [95% CI, 1.29-4.07]; P=0.004). Quality of life was reduced (P=0.004) and did not normalize for 6 months. Disruptions in CIED therapy were experienced in 36% of infections for a median duration of 184 days. Mean costs were $55 547 +/-$45 802 for the hospital, $26 867 +/-$14 893, for medicare fee for service and $57 978 +/-$29 431 for Medicare Advantage (mean hospital margin of -$30 828 +/-$39 757 for medicare fee for service and -$6055 +/-$45 033 for medicare advantage). Mean out-of-pocket costs for patients were $2156 +/-$1999 for medicare fee for service, and $1658 +/-$1250 for medicare advantage. Conclusions: This large, prospective analysis corroborates and extends understanding of the impact of CIED infections as seen in real-world datasets. CIED infections severely impact mortality, quality of life, healthcare utilization, and cost in the US healthcare system.
  •  
2.
  • Ahmed, Fozia Z., et al. (author)
  • Use of healthcare claims to validate the Prevention of Arrhythmia Device Infection Trial cardiac implantable electronic device infection risk score
  • 2021
  • In: Europace. - : Oxford University Press. - 1099-5129 .- 1532-2092. ; 23:9, s. 1446-1455
  • Journal article (peer-reviewed)abstract
    • AIM: The Prevention of Arrhythmia Device Infection Trial (PADIT) infection risk score, developed based on a large prospectively collected data set, identified five independent predictors of cardiac implantable electronic device (CIED) infection. We performed an independent validation of the risk score in a data set extracted from U.S. healthcare claims.METHODS AND RESULTS: Retrospective identification of index CIED procedures among patients aged ≥18 years with at least one record of a CIED procedure between January 2011 and September 2014 in a U.S health claims database. PADIT risk factors and major CIED infections (with system removal, invasive procedure without system removal, or infection-attributable death) were identified through diagnosis and procedure codes. The data set was randomized by PADIT score into Data Set A (60%) and Data Set B (40%). A frailty model allowing multiple procedures per patient was fit using Data Set A, with PADIT score as the only predictor, excluding patients with prior CIED infection. A data set of 54 042 index procedures among 51 623 patients with 574 infections was extracted. Among patients with no history of prior CIED infection, a 1 unit increase in the PADIT score was associated with a relative 28% increase in infection risk. Prior CIED infection was associated with significant incremental predictive value (HR 5.66, P < 0.0001) after adjusting for PADIT score. A Harrell's C-statistic for the PADIT score and history of prior CIED infection was 0.76.CONCLUSION: The PADIT risk score predicts increased CIED infection risk, identifying higher risk patients that could potentially benefit from targeted interventions to reduce the risk of CIED infection. Prior CIED infection confers incremental predictive value to the PADIT score.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view