SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Li Yuanzhe) "

Sökning: WFRF:(Li Yuanzhe)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Beal, Jacob, et al. (författare)
  • Robust estimation of bacterial cell count from optical density
  • 2020
  • Ingår i: Communications Biology. - : Springer Science and Business Media LLC. - 2399-3642. ; 3:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data.
  •  
2.
  •  
3.
  • Li, Shian, et al. (författare)
  • Numerical study on thermal performance of cold plates with leaf type channels for lithium-ion batteries
  • 2023
  • Ingår i: International Journal of Numerical Methods for Heat and Fluid Flow. - 0961-5539. ; 33:10, s. 3519-3534
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The purpose of this study is to design a new type of cold plate to improve the thermal performance of liquid-cooled thermal management system of lithium-ion batteries. Design/methodology/approach: A cold plate with leaf type channels is proposed to enhance the cooling performance. Effects of the leaf type channel parameters (i.e. channel angle 20°, 40°, 60°, 80°; coolant mass flow rate 0.25 × 10–3, 0.50 × 10–3, 0.75 × 10–3, 1.00 × 10–3, 1.25 × 10–3 kg·s−1; channel number 1, 3, 5, 7) on the performance are numerically investigated by using a 3D mathematical model. Findings: Compared to the traditional I type channels, the leaf type channels have better cooling performance. It is found that the battery temperature variation and channel pressure drop are decreased with decreasing channel angle and increasing channel number. In addition, the cooling performance can be improved by increasing the coolant mass flow rate. Practical implications: This study can provide guidance for the development of novel effective cold plates. Originality/value: The design of cold plates with leaf type channels can be used in liquid-cooled thermal management system to reduce the battery temperature difference.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy