SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lilin Thomas) "

Sökning: WFRF:(Lilin Thomas)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Coelho, Paulo G., et al. (författare)
  • Microrobotized blasting improves the bone-to-textured implant response. A preclinical in vivo biomechanical study
  • 2016
  • Ingår i: Journal of The Mechanical Behavior of Biomedical Materials. - : Elsevier. - 1751-6161 .- 1878-0180. ; 56, s. 175-182
  • Tidskriftsartikel (refereegranskat)abstract
    • This study evaluated the effect of microrobotized blasting of titanium endosteal implants relative to their manually blasted counterparts. Two different implant systems were utilized presenting two different implant surfaces. Control surfaces (Manual) were fabricated by manually grit blasting the implant surfaces while experimental surfaces (Microblasted) were fabricated through a microrobotized system that provided a one pass grit blasting routine. Both surfaces were created with the same similar to 50 gm average particle size alumina powder at similar to 310 KPa. Surfaces were then etched with 37% HCl for 20 min, washed, and packaged through standard industry procedures. The surfaces were characterized through scanning electron microscopy (SEM) and optical interferometry, and were then placed in a beagle dog radius model remaining in vivo for 3 and 6 weeks. The implant removal torque was recorded and statistical analysis evaluated implant system and surface type torque levels as a function of time in vivo. Histologic sections were qualitatively evaluated for tissue response. Electron microscopy depicted textured surfaces for both manual and microblasted surfaces. Optical interferometry showed significantly higher S-a, S-q, values for the microblasted surface and no significant difference for S-ds and S-dr values between surfaces. In vivo results depicted that statistically significant gains in biomechanical fixation were obtained for both implant systems tested at 6 weeks in vivo, while only one system presented significant biomechanical gain at 3 weeks. Histologic sections showed qualitative higher amounts of new bone forming around microblasted implants relative to the manually blasted group. Microrobotized blasting resulted in higher biomechanical fixation of endosteal dental implants and should be considered as an alternative for impant surface manufacturing.
  •  
2.
  • Jimbo, Ryo, et al. (författare)
  • Simplified drilling technique does not decrease dental implant osseointegration : a preliminary report
  • 2013
  • Ingår i: Journal of Periodontology. - : American Academy of Periodontology. - 0022-3492 .- 1943-3670. ; 84:11, s. 1599-1605
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: To date, some experimental studies have addressed the effect of bone drilling technique and sequence on dental implant osseointegration. In the present study, the authors hypothesize that there would be no differences in osseointegration when reducing the number of drills for osteotomy compared to the conventional drilling protocols. Methods: Seventy-two implants (diameters 3.75 mm and 4.2 mm; n = 36 for each diameter) were bilaterally placed in the tibia of 18 beagles for 1, 3, and 5 weeks. Half of the implants of each diameter were placed using a simplified drilling procedure (pilot and final drill), and the other half were placed using a conventional drilling procedure (all drills in sequence). The retrieved samples were subjected to histologic and histomorphometric evaluation. Results: Histology showed that new bone formed around the implant, and inflammation or bone resorption was not evident for both groups. Histomorphometrically, the simplified group presented significantly higher bone-to-implant contact and bone area fraction occupancy compared to the conventional group after 1 week; however, no differences were detected at 3 and 5 weeks. Conclusion: Bone responses to the implant with the simplified protocol can be comparable to the conventional protocol.
  •  
3.
  • Jinno, Yohei, et al. (författare)
  • Vertical Bone Augmentation Using Ring Technique with Three Different Materials in the Sheep Mandible Bone
  • 2018
  • Ingår i: International Journal of Oral & Maxillofacial Implants. - : Quintessence. - 0882-2786 .- 1942-4434. ; 33:5, s. 1057-1063
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The purpose of this study was to examine the volumetric alterations and osseointegration properties in the augmented area of the ring technique using different types of bone graft material in sheep mandible bone. Materials and Methods: Three different materials (columnar forms, 7-mm diameter, 3-mm height) were stabilized using dental implants with a turned surface in the mandible bone of Finnish Dorset cross-bred sheep: group A, autogenous bone; group B, bovine bone; group C, biphasic bone substitute. Animals were euthanized after 5 weeks (N = 6). Three-dimensional image data by digital oral scanner were taken at the surgery and sacrifice, and the volume alteration of the material was calculated. The bone samples were fixed in formalin and dehydrated in ethanol. Resin-embedded samples were subjected to non-decalcified ground sectioning, and histologic and histomorphometric analysis (bone and material area alteration, bone-to-implant contact [BIC]) were done. Results: In three-dimensional (3D) image analysis, group A showed a statistically higher percentage of remaining materials compared with groups B and C. The histologic observation showed no new bone formations around the implants in all groups, especially at the maxillary site of the implant in the augmented area. In histomorphometric analysis, group A showed a statistically higher percentage of bone area (BA) compared with groups B and C; however, in all groups, bone-to-implant contact (BIC) showed low values, and there were no statistical differences between groups. Conclusion: The results of this study suggested that the autogenous bone maintained bone volume around the dental implant using the ring technique, and the impact of surface properties was of some importance; osseointegration with the turned surface in the augmented area showed low BIC values in all groups.
  •  
4.
  • Lemo, Niksa, et al. (författare)
  • Cutaneous reepithelialization and wound contraction after skin biopsies in rabbits: a mathematical model for healing and remodelling index
  • 2010
  • Ingår i: VETERINARSKI ARHIV. - 0372-5480. ; 80:5, s. 637-652
  • Tidskriftsartikel (refereegranskat)abstract
    • The objective of this study was to develop a standard operating procedure for the analysis of skin wound healing using histomorphometrical measurements and mathematical data analyses. The mathematical model is derived from observations of normal cutaneous healing in the rabbit. It is designed to allow a simple scoring of the major steps of healing and remodelling. Full-thickness punch biopsies were performed on the skin of the back of New Zealand-white rabbits and healing was analyzed by histopathological examination after 2, 5, 9 and 14 days, using different staining techniques. Histomorphological measurements were also made. The thickness of the epidermis and neo-epidermis were compared. Several indices relative to wound severity and contraction were computed in an attempt to define a global healing index. A remodelling index was calculated based on a colorimetric analysis with Mallory Trichrome staining and hair migration. The changes in index values seemed to correlate with the histopathological analysis. No material flaws appeared when this model was applied to the natural healing process. This model was developed for scoring and accurate comparative evaluation of the effects of various treatments, biomaterials or pharmacological preparations on soft tissue healing and remodelling in rabbits. Although the healing of cutaneous wounds in rabbits differs from that in humans, this model may still be relevant for screening new wound healing preparations.
  •  
5.
  • Neiva, Rodrigo, et al. (författare)
  • Guidelines for Clinical Management of Laser-Etched (Laser-Lok) Abutments in Two Different Clinical Scenarios : A Preclinical Laboratory Soft Tissue Assessment Study
  • 2016
  • Ingår i: The international journal of periodontics & restorative dentistry. - : Quintessence. - 0198-7569 .- 1945-3388. ; 36:3, s. 339-345
  • Tidskriftsartikel (refereegranskat)abstract
    • One-stage implants were placed in the mandibles of eight beagle dogs with laser-etched (LL) and machined abutments. After 4 weeks, half of the LL abutments were disconnected and reconnected after 10 minutes of saline storage, and the other half were replaced with a new LL abutment (impression simulation) with or without sulcus de-epithelialization. After abutment change, systems remained in vivo for 3 weeks. Results showed that LL abutments can be reconnected and that sulcus scoring prior to LL placement of one-stage implants receiving machined abutments may be beneficial.
  •  
6.
  • Neiva, Rodrigo, et al. (författare)
  • The Effect of Laser-Etched Surface Design on Soft Tissue Healing of Two Different Implant Abutment Systems : An Experimental Study in Dogs
  • 2016
  • Ingår i: The international journal of periodontics & restorative dentistry. - : Quintessence. - 0198-7569 .- 1945-3388. ; 36:5, s. 673-679
  • Tidskriftsartikel (refereegranskat)abstract
    • This study describes the early soft tissue morphology around two different implant systems that received either smooth or laser-etched abutments in a beagle dog model. Implants were placed in the healed mandibular molar region of eight beagle dogs and allowed to heal for 7 weeks. When the most apical aspect of the junctional epithelium (JE) was above or within the upper half of the laser-etched region, fibers were oriented perpendicular to the abutment surface. In contrast, JE positioned within the lower half of the laser-etched region or within or below the implant-abutment gap level presented fibers oriented parallel to the abutment surface.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy