SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Liljensten E) "

Sökning: WFRF:(Liljensten E)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Liljensten, E, et al. (författare)
  • Hydroxyapatite granule/carrier composites promote new bone formation in cortical defects.
  • 2000
  • Ingår i: Clinical implant dentistry and related research. - : Wiley. - 1523-0899 .- 1708-8208. ; 2:1, s. 50-9
  • Tidskriftsartikel (refereegranskat)abstract
    • A great deal of interest has been focused on finding substitutes for autogenous bone grafts. Among the most interesting materials are different calcium phosphate compositions (e.g., hydroxyapatite [HA]), due to their biocompatible properties in hard and soft tissue.
  •  
4.
  •  
5.
  • Liljensten, E, et al. (författare)
  • Studies of the healing of bone grafts, and the incorporation of titanium implants in grafted bone: an experimental animal model.
  • 1998
  • Ingår i: Journal of materials science. Materials in medicine. - : Springer Science and Business Media LLC. - 0957-4530 .- 1573-4838. ; 9:9, s. 535-41
  • Tidskriftsartikel (refereegranskat)abstract
    • An insufficient quality and amount of bone often necessitate the clinical use of implants together with bone transplants. The present study describes an experimental animal model for the study of implants in bone grafts. Circular defects were made bilaterally in the tibia of 36 rabbits. The defects received either autologous cortical bone (control), demineralized bone matrix (DBM), plasma-augmented DBM or were left empty (without bone graft). In all defects a titanium implant was centrally placed and anchored in the opposite cortex. Evaluation with light microscopic morphometry showed that the insertion of a threaded titanium implant centrally in a cortical defect was followed by a spontaneous healing of the defect after 6 mon. After 6 wk, all implants in cortical grafts were well integrated with a significantly higher bone-to-implant contact than in the DBM and plasma-augmented groups. After 6 mon, all experimental groups had a mean bone area within the threads ranging between 69% and 80% and a mean bone-to-implant contact between 31% and 42%. The results from the present study indicate that the model allows comparative studies on the early formation, resorption and remodelling of bone around implants after modification of implant, graft and host properties.
  •  
6.
  • Nilsson, Anders, 1958, et al. (författare)
  • Results from a degradable TMC joint Spacer (Artelon) compared with tendon arthroplasty
  • 2005
  • Ingår i: J Hand Surg [Am]. - : Elsevier BV. - 0363-5023. ; 30:2, s. 380-9
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: A new spacer for the trapeziometacarpal joint (TMC) based on a biological and tissue-preserving concept for the treatment of TMC osteoarthritis (OA) has been evaluated. The purpose was to combine a spacing effect with stabilization of the TMC joint. METHODS: Artelon (Artimplant AB, Sweden) TMC Spacer is synthesized of a degradable polyurethaneurea (Artelon), which has been shown to be biocompatible over time and currently is used in ligament augmentation procedures. Fibers of the polymer were woven into a T-shaped device in which the vertical portion separates the bone edges of the TMC joint and the horizontal portion stabilizes the joint. Fifteen patients with disabling pain and isolated TMC OA were included in the study. Ten patients received the spacer device and the remaining 5 (control group) were treated with a trapezium resection arthroplasty with abductor pollicis longus (APL) stabilization. The median ages of the 2 groups were 60 and 59 years, respectively. Pain, strength, stability, and range of motion were measured before and after surgery. Radiographic examination was performed in all patients before and after surgery. At follow-up evaluation 3 years after surgery an unbiased observer evaluated all patients. Biopsy specimens were obtained from 1 patient 6 months after surgery. RESULTS: All patients were stable clinically without signs of synovitis. In both groups all patients were pain free. The median values for both key pinch and tripod pinch increased compared with before surgery in the spacer group but not in the APL group. The biopsy examinations showed incorporation of the device in the surface of the adjacent bone and the surrounding connective tissue. No signs of foreign-body reaction were seen. CONCLUSIONS: This study showed significantly better pinch strength after Artelon TMC Spacer implantation into the TMC joint compared with APL arthroplasty.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy