SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lind Stig) "

Sökning: WFRF:(Lind Stig)

  • Resultat 1-10 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andelin, M., et al. (författare)
  • Assessing the Accuracy of Continuous Glucose Monitoring (CGM) Calibrated With Capillary Values Using Capillary or Venous Glucose Levels as a Reference.
  • 2016
  • Ingår i: Journal of Diabetes Science and Technology. - : Diabetes Technology Society. - 1932-2968. ; 10:4, s. 876-884
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Using the standard venous reference for the evaluation of continuous glucose monitoring (CGM) systems could possibly negatively affect measured CGM accuracy since CGM are generally calibrated with capillary glucose and venous and capillary glucose concentrations differ. We therefore aimed to quantify the effect of using capillary versus venous glucose reference samples on estimated accuracy in capillary calibrated CGM.less thanbr /greater thanMethods: We evaluated 41 individuals with type 1 diabetes mellitus (T1DM) using the Dexcom G4 CGM system over 6 days. Patients calibrated their CGM devices with capillary glucose by means of the HemoCue system. During 2 visits, capillary and venous samples were simultaneously measured by HemoCue and compared to concomitantly obtained CGM readings. The mean absolute relative difference (MARD) was calculated using capillary and venous reference samples.less thanbr /greater thanResults: Venous glucose values were 0.83 mmol/L (15.0 mg/dl) lower than capillary values over all glycemic ranges, P less than .0001. Below 4 mmol/l (72 mg/dl), the difference was 1.25 mmol/l (22.5 mg/dl), P = .0001, at 4-10 mmol/l (72-180 mg/dl), 0.67 mmol/l (12.0 mg/dl), P less than .0001 and above 10 mmol/l (180 mg/dl), 0.95 mmol/l (17.1 mg/dl), P less than .0001. MARD was 11.7% using capillary values as reference compared to 13.7% using venous samples, P = .037. Below 4 mmol/l (72 mg/dl) MARD was 16.6% and 31.8%, P = .048, at 4-10 mmol/l (72-180 mg/dl) 12.1% and 12.6%, P = .32, above 10 mmol/l (180 mg/dl) 8.7% and 9.2%, P = .82.less thanbr /greater thanConclusion: Using capillary glucose concentrations as reference to evaluate the accuracy of CGM calibrated with capillary samples is associated with a lower MARD than using venous glucose as the reference. Capillary glucose concentrations were significantly higher than venous in all glycemic ranges.less thanbr /greater than (© 2016 Diabetes Technology Society.)
  •  
2.
  • Carlsson, Britt-Marie, et al. (författare)
  • Insulin Pump-Long-Term Effects on Glycemic Control: An Observational Study at 10 Diabetes Clinics in Sweden
  • 2013
  • Ingår i: Diabetes Technology & Therapeutics. - : Mary Ann Liebert Inc. - 1520-9156 .- 1557-8593. ; 15:4, s. 302-307
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: This study examined long-term effects of continuous subcutaneous insulin infusion (CSII) in clinical practice on glycemic control in patients with type 1 diabetes. Subjects and Methods: We evaluated all type 1 diabetes patients at 10 diabetes outpatient clinics in Sweden who had been treated with CSII for at least 5.5 years and had valid glycated hemoglobin (HbA1c) data before starting pump use and at 5 years±6 months. Controls treated with multiple daily insulin injections (MDI) over a time-matched period were also evaluated. Results: There were 331 patients treated with CSII at least 5.5 years at the 10 clinics. Of these, 272 (82%) fulfilled the inclusion criteria. Patients treated with CSII were younger than those treated with MDI (mean age, 38.6 vs. 45.6 years; P<0.001), more were women (56% vs. 43%; P<0.001), and diabetes duration was shorter (mean, 15.1 years vs. 20.1 years; P<0.001). After adjusting for variables differing at baseline and influencing the change in HbA1c over the study period, the reduction in HbA1c remained statistically significant at 5 years and was estimated to be 0.20% (95% confidence interval [CI] 0.07–0.32) (2.17mmol/mol [95% CI 0.81–3.53]) (P=0.002). The corresponding adjusted reduction at years 1 and 2 was 0.42% (95% CI 0.31–0.53) (4.59mmol/mol [95% CI 3.41–5.77]) (P<0.001) and 0.43% (95% CI 0.31–0.55) (4.71mmol/mol [95% CI 3.38–6.04]) (P<0.001), respectively. The effect of insulin pump use versus controls on HbA1c decreased significantly with time (P<0.001). Conclusions: Use of CSII in clinical practice in Sweden is associated with an approximately 0.2% (2mmol/mol) reduction in HbA1c after 5 years.
  •  
3.
  •  
4.
  • Dahlqvist, S., et al. (författare)
  • Variables associated with HbA1c and weight reductions when adding liraglutide to multiple daily insulin injections in persons with type 2 diabetes (MDI Liraglutide trial 3)
  • 2018
  • Ingår i: BMC Open Diabetes Research and Care. - : BMJ. - 2052-4897. ; 6:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To evaluate variables associated with hemoglobin A1c (HbA1c) and weight reduction when adding liraglutide to persons with type 2 diabetes treated with multiple daily insulin injections (MDI). Research design and methods This was a reanalysis of a previous trial where 124 patients were enrolled in a double-blind, placebo-controlled, multicenter randomized trial carried out over 24 weeks. Predictors for effect on change in HbA1c and weight were analyzed within the treatment group and with concurrent interaction analyses. Correlation analyses for change in HbA1c and weight from baseline to week 24 were made. Results The mean age at baseline was 63.7 years, 64.8% were men, the mean number of insulin injections was 4.4 per day, the mean daily insulin dose was 105 units and the mean HbA1c was 74.5 mmol/mol (9.0%). The mean HbA1c and weight reductions were 12.3 mmol/mol (1.13%; P<0.001) and 3.8 kg (P<0.001) greater in liraglutide than placebo-Treated persons. There was no significant predictor for greater effect on HbA1c that existed in all analyses (univariate, multivariate and interaction analyses against controls). For a greater weight reduction when adding liraglutide, a lower HbA1c level at baseline was a predictor (liraglutide group P=0.002, P=0.020 for liraglutide group vs placebo). During follow-up in the liraglutide group, no significant correlation was found between change in weight and change in HbA1c (r=0.09, P=0.46), whereas a correlation existed between weight and insulin dose reduction (r=0.44, P<0.001). Conclusion Weight reduction becomes greater when adding liraglutide in patients with type 2 diabetes treated with MDI who had a lower HbA1c level compared with those with a higher HbA1c level. There was no correlation between reductions in HbA1c and weight when liraglutide was added, that is, different patient groups responded with HbA1c and weight reductions. Trial registration number EudraCT nr: 2012-001941-42. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  • Matuleviciene, Viktorija, et al. (författare)
  • A Clinical Trial of the Accuracy and Treatment Experience of the Dexcom G4 Sensor (Dexcom G4 System) and Enlite Sensor (Guardian REAL-Time System) Tested Simultaneously in Ambulatory Patients with Type 1 Diabetes
  • 2014
  • Ingår i: Diabetes Technology & Therapeutics. - : Mary Ann Liebert Inc. - 1520-9156 .- 1557-8593. ; 16:11, s. 759-767
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Continuous glucose monitoring (CGM) is a tool widely used in the treatment of patients with type 1 diabetes. The purpose of the current study was to evaluate whether accuracy and patient treatment satisfaction differ between the Enlite (TM) (Medtronic MiniMed, Inc., Northridge, CA) and Dexcom((R)) (San Diego, CA) G4 PLATINUM CGM sensors. Subjects and Methods: Thirty-eight ambulatory patients with type 1 diabetes used the Dexcom G4 and Enlite sensors simultaneously for a minimum of 4 and maximum of 6 days. Patients measured capillary glucose levels with a HemoCue((R)) (angelholm, Sweden) system six to 10 times a day. In addition, two inpatient studies were performed between Days 1-3 and 4-6. Results: The mean absolute relative difference (MARD) in blood glucose for the Dexcom G4 was significantly lower (13.9%) than for the Enlite sensor (17.8%) (P<0.0001). The corresponding MARDs for Days 1-3 were 15.0% versus 19.4% (P=0.0027) and 13.6% versus 15.9% (P=0.026) for Days 4-6. For glucose levels in the hypoglycemic range (<4.0 mmol/L), the MARD for the Dexcom G4 was 20.0% compared with 34.7% for the Enlite (P=0.0041). On a visual analog scale (VAS) (0-100), patients rated the Dexcom G4 more favorably than the Enlite in 12 out of the 13 user experience questions. For example, more patients rated their experience with the Dexcom G4 as positive (VAS, 79.7 vs. 46.6; P<0.0001) and preferred to use it in their daily lives (VAS, 79.1 vs. 42.1; P<0.0001). Conclusions: The Dexcom G4 sensor was associated with greater overall accuracy than the Enlite sensor during initial (Days 1-3) and later (Days 4-6) use and for glucose levels in the hypoglycemic range. Patients reported a significantly more positive experience using the Dexcom G4 than the Enlite.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 13
Typ av publikation
tidskriftsartikel (11)
konferensbidrag (1)
bokkapitel (1)
Typ av innehåll
refereegranskat (13)
Författare/redaktör
Lind, Marcus, 1976 (8)
Attvall, Stig, 1950 (8)
Dahlqvist, S. (6)
Pivodic, A. (5)
Haraldsson, Börje, 1 ... (4)
Hirsch, I. B. (3)
visa fler...
Clements, M (3)
Ahren, Bo (2)
Theodorsson, Elvar (2)
Ekelund, M. (2)
Filipsson, Karin (2)
Andelin, M. (2)
Joseph, J.I. (2)
Klonoff, D. (2)
Fahlen, M. (2)
Bjartmarz, Hjalmar (2)
Skrtic, Stanko, 1970 (1)
Denvall, Verner (1)
Gerdhem, Paul (1)
Lind, Hans (1)
Liuba, Karina (1)
Torffvit, Ole (1)
Jansson, K. (1)
Zachrisson, O (1)
Svensson, Kerstin (1)
Ahlén, Elsa, 1990 (1)
Imberg, Henrik, 1991 (1)
Gustafsson, T. (1)
Tuomilehto, J. (1)
Hirsch, Irl B. (1)
Sjöberg, Stefan (1)
Svensson, Mikael (1)
Tuomilehto, Jaakko (1)
Svenningsson, Per (1)
Pehrsson, Nils-Gunna ... (1)
Forsberg, Anton (1)
Halldin, Christer (1)
Westgren, Magnus (1)
Svensson, Eva, 1962- (1)
Kropff, J. (1)
Matuleviciene, V. (1)
Imberg, H. (1)
DeVries, J.H. (1)
Sternemalm, L. (1)
Frisen, Jonas (1)
Brodin, Lars-Åke (1)
Almqvist, P (1)
Widner, Håkan (1)
Linderoth, B (1)
Linderoth, Bengt (1)
visa färre...
Lärosäte
Göteborgs universitet (8)
Lunds universitet (6)
Karolinska Institutet (4)
Linköpings universitet (2)
Kungliga Tekniska Högskolan (1)
Chalmers tekniska högskola (1)
visa fler...
Karlstads universitet (1)
visa färre...
Språk
Engelska (12)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (11)
Samhällsvetenskap (1)
Humaniora (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy