SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lindström Svante 1958 ) "

Sökning: WFRF:(Lindström Svante 1958 )

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Falk, Anders B., et al. (författare)
  • Influence of some weather parameters on the susceptibility of apple fruit to postharvest grey mould attack
  • 2018
  • Ingår i: Proceedings 2018. ; , s. 124-127
  • Konferensbidrag (refereegranskat)abstract
    • Several cultural and weather factors during the season influence the susceptibility of apple fruit to post-harvest pathogens. In the present study, the effect of different weather parameters on postharvest susceptibility of apples of the cv. ‘Ingrid Marie’ to grey mould was investigated. In 2015, apple fruit were collected from orchards in Southern Sweden, where local weather stations monitored different parameters. After harvest, the fruit were tested for susceptibility to grey mould by artificially inoculating them with%FLQHUHD. Lesion development was monitored over a 10-day-period. Analysis of results for a few orchards showed that cold weather for over a month preceding harvest and a low total number of growth degree days gave apples that were more susceptible to grey mould. This study was carried out in conventional orchards, but the conclusions can be important also for organic production, since they deal with the general effect of sunshine, temperature and rain, factors that may strengthen fruit during cultivation, regardless of production type. Future studies may focus on organic production to investigate whether these effects are general and also apply to organic production.
  •  
2.
  • Lindskog, Stefan, et al. (författare)
  • Phenotypic expression of a family with multiple endocrine neoplasia type 2A due to a RET mutation at codon 618
  • 2004
  • Ingår i: The British journal of surgery. - : Oxford University Press (OUP). - 0007-1323 .- 1365-2168. ; 91:6, s. 713-8
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Multiple endocrine neoplasia type 2A (MEN2A) is caused by missense mutations in the RET proto-oncogene on chromosome 10. This paper reports the phenotypic expression of a family with MEN2A, in which serine substitutes for cysteine at codon 618 in exon 10 of the RET gene. It was first claimed that medullary thyroid cancer (MTC) with this rare mutation led to mild disease; this has recently been updated to intermediate-high risk, based on stratified genetic information. METHODS: The family was mapped over six generations. In 1971 family members were invited to join a screening programme. Genetic testing was started in 1994. RESULTS: Twenty-two individuals with MTC were identified, 16 by the screening programme. One screened patient had a phaeochromocytoma and four had hyperparathyroidism. At surgery for MTC 12 patients had local tumour metastases and two young patients also had liver metastases. No screened patient died from MTC during a mean observation time of 19 years. Six other family members were diagnosed with MTC by signs and symptoms, five of whom died from MTC. CONCLUSION: Because of the great interindividual differences in tumour aggressiveness within the family it is impossible to predict whether an individual gene carrier will have an aggressive MTC or not. This unpredictability is an additional argument, besides those obtained in stratified genetic studies, for operating on gene carriers at young age.
  •  
3.
  • Mattsson, Magnus, 1964-, et al. (författare)
  • Fan Convectors vs. Bench heaters in Churches – impact on air velocities
  • 2011
  • Ingår i: EEHB 2011. - Visby : Gotland University Press. - 9789186343118
  • Konferensbidrag (refereegranskat)abstract
    • Air movements in churches affect the deposition rate of airborne particles on surfaces, and hence influence soiling of valuable artifacts of different kinds. Sooting from candles and the thermal comfort of people is also affected by indoor air velocities. In an experimental field study, two different heating systems were compared regarding their effect on room air velocities in a church: air-to-air heat pumps with indoor fan convectors vs. a combination of bench heaters and radiators. Hot-sphere and 3-D sonic anemometers were used to record air velocities in the church. Strong buoyant air flows were found both in the supply air flow path of the heat pumps and above the bench heaters, but the air velocities were rather low outside of these air currents. A ~25 cm thick downdraught air flow was found along walls and windows, with a magnitude that was similar at both heating systems and much larger than the outdoor air infiltration rate.
  •  
4.
  • Mattsson, Magnus, 1964-, et al. (författare)
  • Fan pressurization method for measuring air leakage in churches – wind and stack induced uncertainties
  • 2013
  • Ingår i: Conference proceedings: Cultural heritage preservation – 3rd European Workshop on Cultural Heritage Preservation. - 9788888307268 ; , s. 63-68
  • Konferensbidrag (refereegranskat)abstract
    • The air leakage of the building envelope of ancient churches and other historical and monumental buildings has impact on energy consumption, thermal comfort, humidity and indoor surface soiling. To measure the air leakage in such large and naturally ventilated single-zone buildings is however challenging, especially due to wind and buoyancy (stack) induced disturbances. This study describes experiences in this regard, attainedat field tests where the fan pressurization technique (“Blower door”) was employed. Reference is made to the European test standard EN 13829. Also results of wind-tunnel tests are utilized. It is shown that both buoyancy and wind at commonly occurring conditions can cause significant uncertainty in fan pressurization tests, and that some of the directions in the standard might need to be strengthened or amended. While the uncertainty in measured air leakage rate at the standard (high) pressure of 50 Pa may be small, the predictions of the air leakage rate occurring at realistically (low) indoor-outdoor pressures tend to suffer from significant uncertainty. That uncertainty is then conveyed to later utilizations of the test results, e.g. building energy modeling and prediction. It is also shown that the wind induced pressure at buildings like churches extends a considerable way out into the surroundings of the building; in the order of two times the building height. This has particular importance when choosing a reference point for outdoorpressure measurement.
  •  
5.
  • Mattsson, Magnus, 1964-, et al. (författare)
  • Impact of heating system on air velocities in a medieval stone church
  • 2011
  • Ingår i: Roomvent 2011. - Trondheim, Norge : Tapir Akademisk Forlag. - 9788251928120
  • Konferensbidrag (refereegranskat)abstract
    • The air flow pattern and magnitude of air velocities in churches and other historic buildings are of interest since they influence the deposition rate of airborne particles on surfaces, and hence affect soiling of valuable artifacts of different kinds. Increased air movements might also cause enhanced sooting from candles and it has an influence on the thermal comfort of people. The type of installed indoor heating units is likely to be important here since these usually induce substantial air movements through natural or forced convection. In an experimental field study, two different heating systems were compared regarding their effect on room air velocities in a medieval stone church: air-to-air heat pumps with indoor fan convectors vs. a combination of bench heaters and radiators. Hot-sphere anemometers were used to record air velocities in the near-zone of the heat pumps and their surroundings, and 3-D sonic anemometers were used to measure downdraught air velocities at the surfaces of a wall and a window. Smoke was used to visualize air flow patterns.It was found that the heat pumps caused strong buoyant air jets that rose to the ceiling, but that the air velocities were rather low outside of these jets. The bench heaters caused buoyant plumes, which also seemed to attain rather high air velocities and reach the ceiling. As regards downdraught along wall and window, no significant difference between the two heating systems could be seen, although there was a tendency towards slightly higher air velocities at these surfaces when the heat pumps were in use. Since the air flow pattern at the surfaces appeared similar, also the particle deposition mechanisms and soiling rate can be expected to be similar.
  •  
6.
  • Mattsson, Magnus, 1964-, et al. (författare)
  • Methods to Identify Air Leakages in the Building Envelope of Churches
  • 2011
  • Ingår i: EEHB 2011. - Visby, Sweden. - 9789186343118
  • Konferensbidrag (refereegranskat)abstract
    • Frequently there is a wish to reduce the natural ventilation rate in churches in order to save energy and/or improve the thermal comfort. It is then often difficult to ascertain exactly which the dominating leaks in the building envelope are, and where tightening measures would be most effective. A number of different methods to identify these leakages are discussed here. It appears that valuable help can be attained by a combination of several measuring techniques, including IR-thermography, tracer gas and pressure measurements. These techniques can also be useful in verifying the effect of tightening measures.
  •  
7.
  • Mattsson, Magnus, 1964-, et al. (författare)
  • Tracer gas techniques for quantifying the air change rate in churches – field investigation experiences
  • 2011
  • Ingår i: Proc. Roomvent 2011. - Trondheim, Norge : Tapir Akademisk Forlag. - 9788251928120
  • Konferensbidrag (refereegranskat)abstract
    • Two different tracer gas techniques for quantifying the air change rate were tested in three naturally ventilated churches. The techniques were the decay method (or tracer gas dilution method) and a passive tracer gas method. It appeared that the room air in the studied churches tended to be fairly well mixed when the churches are heated, presumably due to strong natural convection air currents occurring at heat sources and cooler outer building surfaces. This seems to entail that both the decay and the passive method are fairly easy to apply during times of heating. It then doesn’t seem to matter much were the tracer gas is injected or where it is sampled. During non-heating periods, however, spatial differences in tracer gas concentrations were observed, making tracer gas measurements more difficult to perform.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy