SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Linez F.) "

Sökning: WFRF:(Linez F.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Pegourie, B., et al. (författare)
  • Deuterium inventory in Tore Supra : Coupled carbon-deuterium balance
  • 2013
  • Ingår i: Journal of Nuclear Materials. - : Elsevier BV. - 0022-3115 .- 1873-4820. ; 438:Suppl., s. S120-S125
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents an analysis of the carbon-deuterium circulation and the resulting balance in Tore Supra over the period 2002-2007. Carbon balance combines the estimation of carbon gross erosion from spectroscopy, net erosion and deposition using confocal microscopy, lock-in thermography and SEM, and a measure of the amount of deposits collected in the vacuum chamber. Fuel retention is determined from post-mortem (PM) analyses and gas balance (GB) measurements. Special attention was paid to the deuterium outgassed during the nights and weekends of the experimental campaign (vessel under vacuum, Plasma Facing Components at 120 degrees C) and during vents (vessel at atmospheric pressure, PFCs at room temperature). It is shown that this outgassing is the main process reconciling the PM and GB estimations of fuel retention, closing the coupled carbon-deuterium balance. In particular, it explains why the deuterium concentration in deposits decreases with increasing depth.
  •  
2.
  • Tsitrone, E., et al. (författare)
  • Multi machine scaling of fuel retention in 4 carbon dominated tokamaks
  • 2011
  • Ingår i: Journal of Nuclear Materials. - : Elsevier BV. - 0022-3115 .- 1873-4820. ; 415:1, s. S735-S739
  • Tidskriftsartikel (refereegranskat)abstract
    • In order to benchmark predictions for the in vessel tritium inventory in ITER, a survey of fuel retention measured in 4 carbon dominated tokamaks (TEXTOR, ASDEX Upgrade in the 2002-2003 carbon configuration, Tore Supra and JET) was performed, showing retention rates from similar to 1 g D/h in TEXTOR (L mode, limiter machine) up to similar to 6-12 g D/h in AUG (H mode, divertor machine). A simple scaling used for ITER predictions is applied for comparison with experimental values: (1) estimate of wall fluxes, (2) estimate of the gross carbon erosion, (3) estimate of the net erosion/redeposition assuming a redeposition fraction and (4) estimate of the retention rate using D/C ratio scalings. The validity of each step is discussed, showing that this approach yields the right order of magnitude, but tends to underestimate the experimental values unless a high wall flux, a low local redeposition fraction and/or a high D/C ratio are used.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy