SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Liu Yujie 1995 ) "

Sökning: WFRF:(Liu Yujie 1995 )

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Liu, Yujie, 1995- (författare)
  • Spectroelectrochemistry with Ultrathin lon-Selective Membranes
  • 2023
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Rapid and decentralized chemical sensing strategies are highly demanded in contemporary society to monitor ongoing processes relevant to the environment, food analysis, healthcare, sports performance, etc. In this context, ion-selective electrodes (ISEs) based on polymeric membranes have emerged as a promising analytical technique owing to their features of low cost, portability, versatility, and energy efficiency. Despite their undeniable success in potentiometric sensing, the interrogation of such electrodes under dynamic electrochemical techniques opens new horizons. An interesting example is voltammetric ISEs comprising the tandem ultrathin membranes and poly(3-octylthiophene) (POT) as the redox mediator. In these ISEs, ion transfer (IT) processes at the sample-membrane interface can be modulated by the electron transfer (ET) at the underlaying POT film, presenting an interconnected IT-ET system that is promising for various analytical purposes.Conveniently, the UV-Vis absorption spectra of a POT film present clear differences between its oxidized and reduced forms. Accordingly, spectroelectrochemical properties of POT can be dynamically monitored to track the ET in the film, and ultimately the associated IT processes, in voltammetric ISEs. Effectively, the obtained information is valuable from both a theoretical and analytical application point of views. In this regard, this doctoral project focuses on the spectroelectrochemical study of voltammetric ISEs based on ultrathin ion-selective membranes interconnected with POT films.The first chapter provides a general introduction to the concepts involved in this thesis, emphasizing the all-solid-state ISEs, the development of ultrathin membranes working under voltammetric mode, and UV-Vis spectroelectrochemistry. The second chapter describes the experimental details of the thesis. The third chapter, which is composed of four sections, presents the main results of this thesis and the corresponding discussions.More in detail, the first section reports the utilization of spectroelectrochemistry to characterize the correlation between IT and ET processes in voltammetric ISEs. The dynamic absorbance readout unequivocally corresponds to the ET process resulting along the gradual oxidation of POT. The electrochemical signal, whichinvolves dynamically integrated charge, describes in turn the IT process at the membrane-solution interface. The two processes are proved to be totally interconnected, both exhibiting sigmoidal-shaped features that can be described with the mathematical Boltzmann-Sigmoidal model.The second section presents the visualization of ionophore-assisted and nonassisted IT processes along the same voltammetric scan of a voltammetric ISE, using a series of ultrathin membranes rationalized to produce assisted and nonassisted ITs at different degrees. Essentially, the modification of the ionophore/ion exchanger molar ratio in the membrane tunes the nature of the IT peaks (for the analyte binding with ionophore or not). This derives into the easy calculation of important thermodynamic parameters (e.g., selectivity coefficients and binding constants) based on a semi-empirical approach.The third section investigates the analytical application of the interconnected IT-ET processes based on spectroelectrochemistry. Advantageously, by changing the initial accumulation protocol of the analyte into the membrane, three distinct working ranges at millimolar, micromolar, and nanomolar concentration levels can be realized by the same ISE using absorbance-based readout. Notably, this is a very unique performance for an analytical technique.The fourth section explores the possibility of calibration-free sensing based on theinterconnected IT-ET mechanism. Effectively, introducing a thin-layer sample makes it feasible to achieve complete transport of a cation (e.g., potassium) from the sample to the membrane and vice versa through a cyclic voltammetryinterrogation. Importantly, the charge under the IT peak can be directly utilized for calculating the concentration in the sample, precisely knowing the volume in the developed microfluidic cell. This investigation has demonstrated the huge potential of the developed ISEs (integrated in a microfluidic format) towards the realization of calibration-free analytical determinations.
  •  
2.
  •  
3.
  • Liu, Yujie, 1995-, et al. (författare)
  • Voltammetric Ion-Selective Electrodes in Thin-Layer Samples : Absolute Detection of Ions Using Ultrathin Membranes
  • 2024
  • Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 96:3, s. 1147-1155
  • Tidskriftsartikel (refereegranskat)abstract
    • Calibration-free sensors are generally understood as analytical tools with no need for calibration apart from the initial one (i.e., after its fabrication). However, an "ideal" and therefore "more restricted" definition of the concept considers that no calibration is necessary at all, with the sensor being capable of directly providing the analyte concentration in the sample. In the electroanalysis field, investigations have been directed to charge-based readouts (i.e., coulometry) that allow for concentration calculation via the Faraday Law: The sample volume must be precisely defined and the absoluteness of the electrochemical process in which the analyte is involved must be ensured (i.e., the analyte in the sample is similar to 100% converted/transported). Herein, we report on the realization of calibration-free coulometric ISEs based on ultrathin ion-selective membranes, which is demonstrated for the detection of potassium ions (K+). In essence, the K+ transfer at the membrane-sample interface is modulated by the oxidation state of the conducting polymer underlying the membrane. The accumulation/release of K+ to/from the membrane is an absolute process owing to the confinement of the sample to a thin-layer domain (thickness of <100 mu m). The capacity of the membrane expressed in charge is fixed to ca. 18 mu C, and this dictates the detection of micromolar levels of K+ present in ca. 5 mu L sample volume. The system is interrogated with cyclic voltammetry to obtain peaks related to the K+ transfer that can be treated charge-wise. The conceptual and technical innovative steps developed here made the calibration-free detection of K+ possible in artificial and real samples with acceptable accuracy (<10% difference compared with the results obtained from a current-based calibration and ion chromatography). The charge-based analysis does not depend on temperature and appeared to be repetitive, reproducible, and reversible in the concentration range from 1 to 37.5 mu M, with an average coulometry efficiency of 96%.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy