SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lund Eva 1944 ) "

Sökning: WFRF:(Lund Eva 1944 )

  • Resultat 1-10 av 22
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Komaguchi, K, et al. (författare)
  • An ESR and ENDOR study of irradiated 6Li-formate
  • 2007
  • Ingår i: Spectrochimica Acta Part A - Molecular and Biomolecular Spectroscopy. - : Elsevier BV. - 1386-1425 .- 1873-3557. ; 66:3, s. 754-760
  • Tidskriftsartikel (refereegranskat)abstract
    • Lithium formate (6LiOOCH·H2O), 95% 6Li enrichment, combined with an exchange of crystallization water with D2O was investigated. The ESR spectrum of the radiation induced free radicals stable at room temperature consists of a singlet with a narrow line width, 0.92 mT. 6Li has smaller magnetic moment and nuclear spin, which resulted in the narrower line width accompanied with an increase in peak amplitude. In comparison with lithium formate with natural isotopic composition, 6Li (7.5%, I = 1) and 7Li (92.5%, I = 3/2), the sensitivity was increased by a factor of two. With optimised spectrometer settings 6Li formate had seven times higher sensitivity compared to alanine. Therefore this material is proposed as a dosimeter material in a dose range down to 0.1 Gy. The g and the 13C-hyperfine (hf) tensors of the CO2- radical anion, major paramagnetic products, were evaluated to be g = (2.0037, 1.9975, 2.0017), and A(13C) = (465.5, 447.5, 581.3) MHz for polycrystalline samples at room temperature. Furthermore, the 1H-hf and 6Li-hf tensors observed for the surroundings of CO2- by ENDOR technique were in fairly good agreement with DFT calculations. The CO2- radicals are found to be so stable that the formate is applicable to the ESR dosimetry, because of fully relaxing in a fully relaxed geometrical structure of the CO2- component and remaining tight binding with the surroundings after the H atom detachment from HCO2-. © 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Lund, Anders, et al. (författare)
  • New materials for ESR dosimetry
  • 2002
  • Ingår i: Spectrochimica Acta Part A - Molecular and Biomolecular Spectroscopy. - 1386-1425 .- 1873-3557. ; 58:6, s. 1301-1311
  • Tidskriftsartikel (refereegranskat)abstract
    • New materials for electron spin resonance (ESR) dosimetry have been investigated with the aim to find systems more sensitive than L-alanine accepted as a standard for high dose determinations. Among the investigated systems ammonium tartrate, 2-methylalanine, salts of formic acids and dithionates have been found to be more sensitive than alanine by a factor 2-10. The lower limit applies to tissue equivalent materials, while much higher sensitivities were obtained with formates and dithionates containing heavier atoms. The increased sensitivity was mainly attributed to suitable ESR properties of the room temperature stable radicals as regards spectral shape (narrow lines, little or no hyperfine structure) and microwave saturation properties (short relaxation times). The radical structures have when necessary been clarified by ENDOR spectroscopy, while the saturation properties have been screened by pulsed ESR measurements.
  •  
3.
  •  
4.
  • Nilsson, Jonas, 1969-, et al. (författare)
  • The effects of UV-irradiation on the ESR-dosimetry of tooth enamel
  • 2001
  • Ingår i: Applied Radiation and Isotopes. - 0969-8043 .- 1872-9800. ; 54:1, s. 131-139
  • Tidskriftsartikel (refereegranskat)abstract
    • Tooth enamel has been shown to be an excellent dosimeter material for retrospective dosimetry. A complication is that it is sensitive to ultraviolet light (UV), creating a signal that interferes with the dosimetric signal. Irradiation of tooth enamel by UV-light induces a mixture of stable and unstable free radicals. The unstable radicals disappear in about three weeks. Stable radicals are created both at the dosimetric peak and at the same g-value as the native peak. The stable peak coinciding with the native peak shows saturation behavior both for UVA/B- and UVC-light. The signal intensity from the sun is roughly estimated to induce a signal comparable to 15 mGy/h from 60 kV X-rays. The blue lamps used by dentists when hardening plastic repairs contain a narrow tail in the UVA/B-region, and it is shown here that these lamps also contribute to the stable peak coincident with the native peak. The contribution to the dosimetry peak, though negligible, at least for the irradiation times is used in this work. Most of the problems with UVA/B-induced signal contributions can probably be avoided by not using front teeth and teeth close to plastic repairs. (C) 2000 Elsevier Science Ltd.Tooth enamel has been shown to be an excellent dosimeter material for retrospective dosimetry. A complication is that it is sensitive to ultraviolet light (UV), creating a signal that interferes with the dosimetric signal. Irradiation of tooth enamel by UV-light induces a mixture of stable and unstable free radicals. The unstable radicals disappear in about three weeks. Stable radicals are created both at the dosimetric peak and at the same g-value as the native peak. The stable peak coinciding with the native peak shows saturation behavior both for UVA/B- and UVC-light. The signal intensity from the sun is roughly estimated to induce a signal comparable to 15 mGy/h from 60 kV X-rays. The blue lamps used by dentists when hardening plastic repairs contain a narrow tail in the UVA/B-region, and it is shown here that these lamps also contribute to the stable peak coincident with the native peak. The contribution to the dosimetry peak, though negligible, at least for the irradiation times is used in this work. Most of the problems with UVA/B-induced signal contributions can probably be avoided by not using front teeth and teeth close to plastic repairs.
  •  
5.
  • Olsson, Sara, 1970-, et al. (författare)
  • Ammonium tartrate as an ESR dosimeter material
  • 1999
  • Ingår i: Applied Radiation and Isotopes. - 0969-8043 .- 1872-9800. ; 50:5, s. 955-965
  • Tidskriftsartikel (refereegranskat)abstract
    • This study is one step in the search for an ESR dosimeter material with a higher signal intensity than the commonly used l-α-alanine, to be useful in the clinical dose range (approximately 0.1–20 Gy). The substance ammonium tartrate was found and investigated regarding signal intensity, radical stability, dose response and dose resolution. The ESR signal intensity of ammonium tartrate was shown to be more than twice the intensity of the alanine signal. The data indicate that an unstable radiation induced radical contributes to the ESR signal initially; after a couple of hours it has converted to a secondary radical which has a decay slow enough to be considered stable during the first two weeks after irradiation. Ammonium tartrate has a linear dose response in the investigated range of 0.5–4000 Gy and a dose resolution of 0.1 Gy at the 0.5 Gy level where, as a comparison, the corresponding value for alanine is 0.3 Gy. We thus find the substance suitable for clinical dosimetry.
  •  
6.
  • Olsson, Sara K., 1970-, et al. (författare)
  • Development of ammonium tartrate as an ESR dosimeter material for clinical purposes
  • 2000
  • Ingår i: Applied Radiation and Isotopes. - 0969-8043 .- 1872-9800. ; 52:5, s. 1235-1241
  • Tidskriftsartikel (refereegranskat)abstract
    • The crystalline substance ammonium tartrate is investigated with respect to its suitability as a clinical dosimetry material. The properties investigated are: the radical stability for absorbed doses relevant for clinical use, the improvement in sensitivity when the crystals are deuterated and the linear electron tranfer (LET)-dependence. After photon irradiation to an absorbed dose of 20 Gy, the signal increases rapidly during the first 6 h. After this period, the changes are more moderate and can be corrected for. The signal-to-noise ratio of irradiated ammonium tartrate is twice the corresponding value of alanine. By deuterating the crystals, the sensitivity can be further improved by a factor of 1.4. As expected, the signal decreases with increasing LET of the radiation, but no changes in the spectrum shape was observed.
  •  
7.
  • Olsson, Sara, 1970-, et al. (författare)
  • Radiation dose measurements with alanine/agarose gel and thin alanine films around a 192Ir brachytherapy source, using ESR spectroscopy
  • 2002
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 47:8, s. 1333-1356
  • Tidskriftsartikel (refereegranskat)abstract
    • Alanine/agarose gel and alanine films in stacks have been used for measurements of absorbed dose around an HDR 192Ir source in a vaginal cylinder-applicator, with and without a 180° tungsten shield. The gel and the films were analysed by means of ESR spectroscopy and calibrated against an ion chamber in a 4 MV photon beam to obtain absolute dose values. The gel serves as both dosimeter and phantom material, and the thin (130 μm) films are used to achieve an improved spatial resolution in the dose estimations.Experimental values were compared with Monte Carlo simulations using two different codes. Results from the measurements generally agree with the simulations to within 5%, for both the alanine/agarose gel and the alanine films.
  •  
8.
  • Sastry, M, et al. (författare)
  • 51V(n,β)52Cr reaction for neutron dosimetry : Development and assessment of a spectrophotometric method for determination of Cr in vanadium at sub ppm level
  • 2004
  • Ingår i: Spectrochimica Acta Part A - Molecular and Biomolecular Spectroscopy. - : Elsevier BV. - 1386-1425 .- 1873-3557. ; 60:10, s. 2363-2367
  • Tidskriftsartikel (refereegranskat)abstract
    • With a view to monitoring the changes in coloration caused by the nuclear reaction 51V(n,β)52Cr in solution of vanadyl sulphate and using it for neutron dosimetry, electronic absorption spectra of vanadyl sulphate solutions were investigated at different concentrations of chromate impurity in micromolar range. It was observed that the presence of chromate enhances the absorptivity over a wide wavelength range serving essentially as a colouring agent for vanadium matrix, presumably due to charge transfer process. The absorbance at 380nm varied linearly over a wide concentration range. The limit of detection of chromate obtained is shown to be adequate for detecting neutron-induced chemical transmutation of vanadium to chromium under standard reactor conditions, when used with long path length cells. It was observed that the absorbance does not change on electron irradiation, suggesting that radiolytic effects due to beta decay, if any, do not interfere in the measurement of neutron-induced changes. In addition to its potential for neutron dosimetry, this is the first report of a simple and direct method of estimation of Cr in vanadium matrix at sub ppm level.
  •  
9.
  • Adolfsson, Emelie, 1985-, et al. (författare)
  • Response of Lithium Formate EPR Dosimeters at Photon Energies Relelvant to Brachytherapy
  • 2009
  • Ingår i: IFMBE Proceedings. - Heidelberg : Springer Berlin Heidelberg. - 9783642034725 - 9783642034749 ; , s. 236-239
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • After development of sensitive dosimeter materials Electron Paramagnetic Resonance EPR dosimetry has been successfully used also in radiation therapy. The intensity of the EPR-signal is a measure of the amount of free radicals created by ionizing radiation which is proportional to the absorbed dose in the dosimeter. Lithium formate monohydrate is a dosimeter material with 2-6 times higher sensitivity than alanine, a linear dose response over a wide dose range and mass-energy absorption properties similar to water. These properties make lithium formate promising for verification of absorbed doses around high dose rate brachytherapy sources where the dose gradient is steep and the photon energy distribution changing with distance from the source. Calibration of the dosimeters is performed in 60Co or MV photon beams where high dosimetric accuracy is feasible. The use in brachytherapy field relies on the assumption that the production of free radicals per mean absorbed dose in the dosimeter is similar at the lower photon energies present there. The aim of this work was to test that assumption. The response of the dosimeters as a function of photon energy was determined by irradiations with four x-ray qualities in the range 100-250 kV and 137Cs, relative to the response when irradiated with 60Co, all photon beams with well-known air kerma rates at the Swedish Secondary Standards Dosimetry Laboratory. Monte Carlo simulations were used to convert air kerma free in air to mean absorbed dose to the dosimeter. The measured response relative 60Co as a function of photon energy was below unity for all qualities. The maximum deviation from unity was 2.5% (100 kV, 135 kV) with a relative standard deviation of 1.5% (k = 1).
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 22
Typ av publikation
tidskriftsartikel (13)
konferensbidrag (8)
doktorsavhandling (1)
Typ av innehåll
refereegranskat (13)
övrigt vetenskapligt/konstnärligt (9)
Författare/redaktör
Lund, Eva, 1944- (21)
Gustafsson, Håkan, 1 ... (5)
Dahlqvist Leinhard, ... (4)
Lundberg, Peter, 195 ... (4)
Salerud, Göran, 1954 ... (4)
Lund, Anders (4)
visa fler...
Lund, Anders, 1938- (3)
Olsson, Sara, 1970- (3)
Alm Carlsson, Gudrun ... (2)
Brandejsky, Vaclav (2)
Sastry, M (2)
Karlsson, Anette (1)
Gustafsson, Håkan (1)
Adolfsson, Emelie, 1 ... (1)
Grindborg, Jan-Erik (1)
Carlsson Tedgren, Ås ... (1)
Gerdle, Björn (1)
Lindström, Jan (1)
Sandborg, Michael, 1 ... (1)
Forsgren, Mikael (1)
Gunnarsson, S. (1)
Janerot-Sjöberg, Bir ... (1)
Bengtsson, Ann, 1949 ... (1)
Sörén, B (1)
Bengtsson, Ann (1)
Shiotani, M. (1)
Cohen, L (1)
Lindborg, L (1)
Bonora, M. (1)
Sagstuen, E (1)
Danilczuk, M. (1)
Komaguchi, K (1)
Brandejsky, Vaslav (1)
Matsubara, Y. (1)
Hole, Eli O. (1)
Kruczala, Krzysztof (1)
Schlick, Shulamith (1)
Wirell, Staffan, 194 ... (1)
Carlsson Tedgren, Ås ... (1)
Lund, Eva, Professor ... (1)
Kandarakis, Ioannis, ... (1)
Malinen, E (1)
Vestad, T-A (1)
Hole, E O (1)
Kendall, Sally, 1950 ... (1)
Kyllönen, JE (1)
Grindborg, JE (1)
Nilsson, Jonas, 1969 ... (1)
Bagherian, Shahrbano ... (1)
Bergstrand, Eva S. (1)
visa färre...
Lärosäte
Linköpings universitet (22)
Karolinska Institutet (1)
Språk
Engelska (21)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (1)
Medicin och hälsovetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy