SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Månsson L.G.) "

Sökning: WFRF:(Månsson L.G.)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lanhede, B., et al. (författare)
  • The Influence of Different Technique Factors on Image Quality for Chest Radiographs: Application of the Recent CEC Image Quality Criteria
  • 2000
  • Ingår i: Radiation Protection Dosimetry. - 1742-3406. ; 90:1-2, s. 203-206
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the first this work part of the EU-project, Trial I, was to evaluate and possibly improve the CEC image criteria for radiographic chest images. Chest images of healthy volunteers were acquired using different technique factors. The image criteria were used as a tool to discriminate between the different images. The technique factors were chosen so that the image quality would differ slightly. Four different technique parameters, each with two possible settings, used in clinical practice today, were used: tube voltage - 102 and 141 kV; screen/film speed - 160 and 320; maximum optical density in the parenchyma - 1.3 and 1.8; method for scatter reduction - air gap 30/390 and moving grid40/12. The results showed that the image criteria were able to separate between different technique groups. Some conclusions can be drawn from the results Optical density 1.8 was better than 1.3 independent of the other parameters. . Among the six combinations ranked best , four used tube voltage 141 kV and four used air gap technique for scatter reduction. No difference was seen for screen/film speed. No correlation was seen between the ranking of the systems and patient dose.
  •  
2.
  • Sund, P., et al. (författare)
  • Comparison of two methods for evaluating image quality of chest radiographs
  • 2000
  • Ingår i: Proceedings of SPIE. - : SPIE. ; 3981, s. 251-258
  • Konferensbidrag (refereegranskat)abstract
    • A set of 15 analog chest images was digitized with a high performance scanner and manipulated in terms of noise and resolution to yield three sets of images; the original plus two with different noise and resolution properties. These sets were evaluated with Visual Grading Analysis (VGA) where the observer rates the visibility of certain normal anatomical structures (as described by the European Quality Criteria) compared to a reference image. One of the non-manipulated digitized images was used in an ROC-related method – the Free response Forced Error experiment. Simulated lesions of different contrast and size were randomly superimposed on 50 copies of this image. The images were then manipulated in the same way as the images used for VGA. All observations were done by a group of seven expert radiologists from six different European countries and all images were printed back to film before evaluation. The ranking of the image manipulations was the same for the two methods. Although a strong correlation cannot be predicted with only three sets of images, it is encouraging that the simpler VGA study in some cases might be used as a replacement for the more time- and effort-consuming ROC analysis.
  •  
3.
  • Tingberg, Anders, et al. (författare)
  • Comparison of two methods for evaluation of the image quality of lumbar spine radiographs
  • 2000
  • Ingår i: Radiation Protection Dosimetry. - 1742-3406. ; 90:1, s. 165-168
  • Tidskriftsartikel (refereegranskat)abstract
    • Two methods for visual evaluation of image quality of clinical radiographs have been compared. In visual grading analysis (VGA) specified anatomical structures in an image are visually compared with the same structures in a reference image, and in a free-response forced error (FFE) experiment - an extension of conventional ROC (receiver operating characteristics) analysis - the objective is to correctly localise known lesions. The spatial resolution and noise of digitised clinical radiographs of the lumbar spine were altered by image processing, and pathological structures were added to the images for the FFE experiment. The images were printed to film and evaluated by seven European expert radiologists using VGA and FFE. The results of these two different methods showed a very good agreement. In conclusion, VGA methodology can be made as solid as the FFE experiment for evaluating image quality. The simplicity of VGA makes it very suitable for implementation in clinical practice.
  •  
4.
  • Tingberg, Anders, et al. (författare)
  • Evaluation of lumbar spine images with added pathology
  • 2000
  • Ingår i: Proceedings of SPIE. - : SPIE. - 0819435988 ; 3981, s. 34-42
  • Konferensbidrag (refereegranskat)abstract
    • Optimisation of radiographic procedures require solid tools for evaluation of the image quality in order to ensure that it is sufficient to answer the clinical question at the lowest possible absorbed dose to the patient. Lumbar spine radiography is an examination giving a relatively high dose and good methods for evaluation of image quality as well as dose are needed. We have developed and used a method for the addition of artificial pathological structures into clinical images. The new images were evaluated in a study of detectability (free-response forced error experiment). The results from the study showed that the methodology can be used to detect differences in the screen-film systems used to produce the images, indicating that the method can be used in a study of image quality. The results of the study of detectability were compared with the outcome of a visual grading analysis based on the structures mentioned in the European Quality Criteria. The comparison indicated that a linear correlation exists between the two methods. This means that the simpler VGA can be used in the evaluation of clinical image quality.
  •  
5.
  • Tingberg, Anders, et al. (författare)
  • The influence of the characteristic curve on the clinical image quality and patient absorbed dose in lumbar spine radiography
  • 2001
  • Ingår i: Proceedings of SPIE. - : SPIE. - 0819440108 ; 4324, s. 41503-41503
  • Konferensbidrag (refereegranskat)abstract
    • The 'European Guidelines on Quality Criteria for Diagnostic Radiographic Images' do not address the choice of film characteristic (H/D) curve, which is an important parameter for the description of a radiographic screen-film system. Since it is not possible to investigate this influence by taking repeated exposures of the same patients on films with systematically varied H/D curves, patient images of lumbar spine were digitised in the current study. The image contrast was altered by digital image processing techniques, simulating images with H/D curves varying from flat over standard latitude to a film type steeper than a mammography film. The manipulated images were printed on film for evaluation. Seven European radiologists evaluated the clinical image quality of in total 224 images by analysing the fulfilment of the European Image Criteria and by visual grading analysis of the images. The results show that the local quality can be significantly improved by the application of films with a steeper film H/D curve compared to the standard latitude film. For images with an average optical density of about 1.25, the application of the steeper film results in a reduction of patient absorbed dose by about 10-15% without a loss of diagnostically relevant image information. The results also show that the patient absorbed dose reduction obtained by altering the tube voltage from 70 kV to 90 kV coincides with a loss of image information that cannot be compensated for by simply changing the shape of the H/D curve.
  •  
6.
  • Tingberg, Anders, et al. (författare)
  • What is worse: Decreased spatial resolution or increased noise?
  • 2002
  • Ingår i: Proceedings of SPIE. - : SPIE. - 9780819444318 ; 4686, s. 338-346
  • Konferensbidrag (refereegranskat)abstract
    • Purpose: To investigate the relative importance of spatial resolution and noise on the image quality of clinical radiographs. Methods: The spatial resolution and noise of fifteen digitised lumbar spine radiographs were altered with image processing. Three different MTF curves and three different Wiener spectra were combined into seven different combinations of spatial resolution and noise. These seven combinations were applied to the original data set, and the resulting images were printed on film. Seven expert radiologists evaluated the clinical image quality of the resulting images with visual grading analysis (VGA) of structures based on the European Image Criteria. Results: The results show that added noise is more deteriorating than reduced spatial resolution for the clinical image quality. For a given MTF and noise level, the worst was the one with increased noise followed by the one with both reduced MTF and added noise (mimicking a faster screen-film combination). Reduced MTF only gave the highest rating. Conclusions: It is more important to find methods for removing noise than to try to improve the MTF of a radiographic system. A noisy image can sometimes be improved by reducing the spatial resolution.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy