SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Müller Rolf) "

Sökning: WFRF:(Müller Rolf)

  • Resultat 1-10 av 50
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Savelyev, Evgeny, et al. (författare)
  • Jitter-correction for IR/UV-XUV pump-probe experiments at the FLASH free-electron laser
  • 2017
  • Ingår i: New Journal of Physics. - : IOP Publishing. - 1367-2630. ; 19:4
  • Tidskriftsartikel (refereegranskat)abstract
    • In pump-probe experiments employing a free-electron laser (FEL) in combination with a synchronized optical femtosecond laser, the arrival-time jitter between the FEL pulse and the optical laser pulse often severely limits the temporal resolution that can be achieved. Here, we present a pump-probe experiment on the UV-induced dissociation of 2,6-difluoroiodobenzene (C6H3F2I) molecules performed at the FLASH FEL that takes advantage of recent upgrades of the FLASH timing and synchronization system to obtain high-quality data that are not limited by the FEL arrival-time jitter. We discuss in detail the necessary data analysis steps and describe the origin of the time-dependent effects in the yields and kinetic energies of the fragment ions that we observe in the experiment.
  •  
2.
  • Amini, Kasra, et al. (författare)
  • Alignment, orientation, and Coulomb explosion of difluoroiodobenzene studied with the pixel imaging mass spectrometry (PImMS) camera
  • 2017
  • Ingår i: Journal of Chemical Physics. - : AIP Publishing. - 0021-9606 .- 1089-7690. ; 147:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Laser-induced adiabatic alignment and mixed-field orientation of 2,6-difluoroiodobenzene (C6H3F2I) molecules are probed by Coulomb explosion imaging following either near-infrared strong-field ionization or extreme-ultraviolet multi-photon inner-shell ionization using free-electron laser pulses. The resulting photoelectrons and fragment ions are captured by a double-sided velocity map imaging spectrometer and projected onto two position-sensitive detectors. The ion side of the spectrometer is equipped with a pixel imaging mass spectrometry camera, a time-stamping pixelated detector that can record the hit positions and arrival times of up to four ions per pixel per acquisition cycle. Thus, the time-of-flight trace and ion momentum distributions for all fragments can be recorded simultaneously. We show that we can obtain a high degree of one-and three-dimensional alignment and mixed-field orientation and compare the Coulomb explosion process induced at both wavelengths.
  •  
3.
  • Amini, Kasra, et al. (författare)
  • Photodissociation of aligned CH3I and C6H3F2I molecules probed with time-resolved Coulomb explosion imaging by site-selective extreme ultraviolet ionization
  • 2018
  • Ingår i: Structural Dynamics. - : AIP Publishing. - 2329-7778. ; 5:1
  • Tidskriftsartikel (refereegranskat)abstract
    • We explore time-resolved Coulomb explosion induced by intense, extreme ultraviolet (XUV) femtosecond pulses from a free-electron laser as a method to image photo-induced molecular dynamics in two molecules, iodomethane and 2,6-difluoroiodobenzene. At an excitation wavelength of 267 nm, the dominant reaction pathway in both molecules is neutral dissociation via cleavage of the carbon-iodine bond. This allows investigating the influence of the molecular environment on the absorption of an intense, femtosecond XUV pulse and the subsequent Coulomb explosion process. We find that the XUV probe pulse induces local inner-shell ionization of atomic iodine in dissociating iodomethane, in contrast to non-selective ionization of all photofragments in difluoroiodobenzene. The results reveal evidence of electron transfer from methyl and phenyl moieties to a multiply charged iodine ion. In addition, indications for ultrafast charge rearrangement on the phenyl radical are found, suggesting that time-resolved Coulomb explosion imaging is sensitive to the localization of charge in extended molecules.
  •  
4.
  • Griessbach, Sabine, et al. (författare)
  • Aerosol and cloud top height information of Envisat MIPAS measurements
  • 2020
  • Ingår i: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 13:3, s. 1243-1271
  • Tidskriftsartikel (refereegranskat)abstract
    • Infrared limb emission instruments have a long history in measuring clouds and aerosol. In particular, the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) instrument aboard ESA's Envisat provides 10 years of altitude-resolved global measurements. Previous studies found systematic overestimations and underestimations of cloud top heights for cirrus and polar stratospheric clouds. To assess the cloud top height information and to characterise its uncertainty for the MIPAS instrument we performed simulations for ice clouds, volcanic ash, and sulfate aerosol. From the simulation results we found that in addition to the known effects of the field-of-view that can lead to a cloud top height overestimation, and broken cloud conditions that can lead to underestimation, the cloud extinction also plays an important role. While for optically thick clouds the possible cloud top height overestimation for MIPAS reaches up to 1.6 km due to the field-of-view, for optically thin clouds and aerosol the systematic underestimation reaches 5.1 km. For the detection sensitivity and the degree of underestimation of the MIPAS measurements, the cloud layer thickness also plays a role; 1 km thick clouds are detectable down to extinctions of 5 x 10(-4) km(-1) and 6 km thick clouds are detectable down to extinctions of 1 x 10(-4) km(-1), where the largest underestimations of the cloud top height occur for the optically thinnest clouds with a vertical extent of 6 km. The relation between extinction coefficient, cloud top height estimate, and layer thickness is confirmed by a comparison of MIPAS cloud top heights of the volcanic sulfate aerosol from the Nabro eruption in 2011 with space- and ground-based lidar measurements and twilight measurements between June 2011 and February 2012. For plumes up to 2 months old, where the extinction was between 1 x 10(-4) and 7 x 10(-4) km(-1) and the layer thickness mostly below 4 km, we found for MIPAS an average underestimation of 1.1 km. In the aged plume with extinctions down to 5 x 10(-5) km(-1) and layer thicknesses of up to 9.5 km, the underestimation was higher, reaching up to 7.2 km. The dependency of the cloud top height overestimations or underestimations on the extinction coefficient can explain seemingly contradictory results of previous studies. In spite of the relatively large uncertainty range of the cloud top height, the comparison of the detection sensitivity towards sulfate aerosol between MIPAS and a suite of widely used UV/VIS limb and IR nadir satellite aerosol measurements shows that MIPAS provides complementary information in terms of detection sensitivity.
  •  
5.
  • Abelev, Betty, et al. (författare)
  • Long-range angular correlations on the near and away side in p-Pb collisions at root S-NN=5.02 TeV
  • 2013
  • Ingår i: Physics Letters. Section B: Nuclear, Elementary Particle and High-Energy Physics. - : Elsevier BV. - 0370-2693. ; 719:1-3, s. 29-41
  • Tidskriftsartikel (refereegranskat)abstract
    • Angular correlations between charged trigger and associated particles are measured by the ALICE detector in p-Pb collisions at a nucleon-nucleon centre-of-mass energy of 5.02 TeV for transverse momentum ranges within 0.5 < P-T,P-assoc < P-T,P-trig < 4 GeV/c. The correlations are measured over two units of pseudorapidity and full azimuthal angle in different intervals of event multiplicity, and expressed as associated yield per trigger particle. Two long-range ridge-like structures, one on the near side and one on the away side, are observed when the per-trigger yield obtained in low-multiplicity events is subtracted from the one in high-multiplicity events. The excess on the near-side is qualitatively similar to that recently reported by the CMS Collaboration, while the excess on the away-side is reported for the first time. The two-ridge structure projected onto azimuthal angle is quantified with the second and third Fourier coefficients as well as by near-side and away-side yields and widths. The yields on the near side and on the away side are equal within the uncertainties for all studied event multiplicity and p(T) bins, and the widths show no significant evolution with event multiplicity or p(T). These findings suggest that the near-side ridge is accompanied by an essentially identical away-side ridge. (c) 2013 CERN. Published by Elsevier B.V. All rights reserved.
  •  
6.
  • Abelev, Betty, et al. (författare)
  • Measurement of prompt J/psi and beauty hadron production cross sections at mid-rapidity in pp collisions at root s=7 TeV
  • 2012
  • Ingår i: Journal of High Energy Physics. - 1029-8479. ; :11
  • Tidskriftsartikel (refereegranskat)abstract
    • The ALICE experiment at the LHC has studied J/psi production at mid-rapidity in pp collisions at root s = 7 TeV through its electron pair decay on a data sample corresponding to an integrated luminosity L-int = 5.6 nb(-1). The fraction of J/psi from the decay of long-lived beauty hadrons was determined for J/psi candidates with transverse momentum p(t) > 1,3 GeV/c and rapidity vertical bar y vertical bar < 0.9. The cross section for prompt J/psi mesons, i.e. directly produced J/psi and prompt decays of heavier charmonium states such as the psi(2S) and chi(c) resonances, is sigma(prompt J/psi) (p(t) > 1.3 GeV/c, vertical bar y vertical bar < 0.9) = 8.3 +/- 0.8(stat.) +/- 1.1 (syst.)(-1.4)(+1.5) (syst. pol.) mu b. The cross section for the production of b-hadrons decaying to J/psi with p(t) > 1.3 GeV/c and vertical bar y vertical bar < 0.9 is a sigma(J/psi <- hB) (p(t) > 1.3 GeV/c, vertical bar y vertical bar < 0.9) = 1.46 +/- 0.38 (stat.)(-0.32)(+0.26) (syst.) mu b. The results are compared to QCD model predictions. The shape of the p(t) and y distributions of b-quarks predicted by perturbative QCD model calculations are used to extrapolate the measured cross section to derive the b (b) over bar pair total cross section and d sigma/dy at mid-rapidity.
  •  
7.
  • Abelev, Betty, et al. (författare)
  • Underlying Event measurements in pp collisions at root s=0.9 and 7 TeV with the ALICE experiment at the LHC
  • 2012
  • Ingår i: Journal of High Energy Physics. - 1029-8479. ; :7
  • Tidskriftsartikel (refereegranskat)abstract
    • We present measurements of Underlying Event observables in pp collisions at root s = 0 : 9 and 7 TeV. The analysis is performed as a function of the highest charged-particle transverse momentum p(T),L-T in the event. Different regions are defined with respect to the azimuthal direction of the leading (highest transverse momentum) track: Toward, Transverse and Away. The Toward and Away regions collect the fragmentation products of the hardest partonic interaction. The Transverse region is expected to be most sensitive to the Underlying Event activity. The study is performed with charged particles above three different p(T) thresholds: 0.15, 0.5 and 1.0 GeV/c. In the Transverse region we observe an increase in the multiplicity of a factor 2-3 between the lower and higher collision energies, depending on the track p(T) threshold considered. Data are compared to PYTHIA 6.4, PYTHIA 8.1 and PHOJET. On average, all models considered underestimate the multiplicity and summed p(T) in the Transverse region by about 10-30%.
  •  
8.
  •  
9.
  • Bajbouj, Malek, et al. (författare)
  • Two-year outcome of vagus nerve stimulation in treatment-resistant depression
  • 2010
  • Ingår i: Journal of Clinical Psychopharmacology. - : Lippincott Williams & Wilkins. - 0271-0749 .- 1533-712X. ; 30:3, s. 273-281
  • Tidskriftsartikel (refereegranskat)abstract
    • One of the major goals of antidepressant treatment is a sustained response and remission of depressive symptoms. Some of the previous studies of vagus nerve stimulation (VNS) have suggested antidepressant effects. Our naturalistic study assessed the efficacy and the safety of VNS in 74 European patients with therapy-resistant major depressive disorder. Psychometric measures were obtained after 3, 12, and 24 months of VNS. Mixed-model repeated-measures analysis of variance revealed a significant reduction (P < or = 0.05) at all the 3 time points in the 28-item Hamilton Rating Scale for Depression (HRSD28) score, the primary outcome measure. After 2 years, 53.1% (26/49) of the patients fulfilled the response criteria (> or =50% reduction in the HRSD28 scores from baseline) and 38.9% (19/49) fulfilled the remission criteria (HRSD28 scores < or = 10). The proportion of patients who fulfilled the remission criteria remained constant as the duration of VNS treatment increased. Voice alteration, cough, and pain were the most frequently reported adverse effects. Two patients committed suicide during the study; no other deaths were reported. No statistically significant differences were seen in the number of concomitant antidepressant medications. The results of this 2-year open-label trial suggest a clinical response and a comparatively benign adverse effect profile among patients with treatment-resistant depression.
  •  
10.
  • Best, Myron G., et al. (författare)
  • Swarm Intelligence-Enhanced Detection of Non-Small-Cell Lung Cancer Using Tumor-Educated Platelets
  • 2017
  • Ingår i: Cancer Cell. - : Elsevier. - 1535-6108 .- 1878-3686. ; 32:2, s. 238-252
  • Tidskriftsartikel (refereegranskat)abstract
    • Blood-based liquid biopsies, including tumor-educated blood platelets (TEPs), have emerged as promising biomarker sources for non-invasive detection of cancer. Here we demonstrate that particle-swarm optimization (PSO)-enhanced algorithms enable efficient selection of RNA biomarker panels from platelet RNA sequencing libraries (n = 779). This resulted in accurate TEP-based detection of early- and late-stage non-small-cell lung cancer (n = 518 late-stage validation cohort, accuracy, 88%; AUC, 0.94; 95% CI, 0.92-0.96; p < 0.001; n = 106 early-stage validation cohort, accuracy, 81%; AUC, 0.89; 95% CI, 0.83-0.95; p < 0.001), independent of age of the individuals, smoking habits, whole-blood storage time, and various inflammatory conditions. PSO enabled selection of gene panels to diagnose cancer from TEPs, suggesting that swarm intelligence may also benefit the optimization of diagnostics readout of other liquid biopsy biosources.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 50
Typ av publikation
tidskriftsartikel (42)
konferensbidrag (2)
forskningsöversikt (2)
bokkapitel (2)
rapport (1)
doktorsavhandling (1)
visa fler...
visa färre...
Typ av innehåll
refereegranskat (42)
övrigt vetenskapligt/konstnärligt (7)
populärvet., debatt m.m. (1)
Författare/redaktör
Adolfsson, Rolf (14)
Djurovic, S (10)
Craddock, N (10)
Kirov, G (10)
Cichon, S (10)
Muller-Myhsok, B (10)
visa fler...
Rietschel, M (10)
Degenhardt, F (10)
Ripke, S (10)
McQuillin, A (10)
Melle, I (9)
Herms, S. (9)
Frank, J (9)
Maier, W (9)
Byerley, W (9)
Agartz, I (8)
Werge, T (8)
Hoffmann, P (8)
Mattheisen, M (8)
Mors, O (8)
Esko, T (8)
Strohmaier, J (8)
Escott-Price, V (8)
Milani, L (8)
Posthuma, D (8)
Del-Favero, J (8)
Curtis, D. (8)
Steinberg, S (7)
Landén, Mikael, 1966 (7)
St Clair, D (7)
Agerbo, E (7)
Jones, I. (7)
Roussos, P (7)
Metspalu, A (7)
Stefansson, K (7)
Bellivier, F. (7)
Cervantes, P. (7)
Cruceanu, C. (7)
Etain, B. (7)
Jamain, S. (7)
Grigoroiu-Serbanescu ... (7)
Kittel-Schneider, S. (7)
Leboyer, M. (7)
Reif, A. (7)
Streit, F (7)
Stefansson, H. (7)
Gill, M. (7)
Sigurdsson, E (7)
Dannlowski, U (7)
Gordon-Smith, K. (7)
visa färre...
Lärosäte
Umeå universitet (18)
Karolinska Institutet (13)
Sveriges Lantbruksuniversitet (10)
Lunds universitet (9)
Göteborgs universitet (8)
Uppsala universitet (8)
visa fler...
Stockholms universitet (8)
Luleå tekniska universitet (3)
Linköpings universitet (2)
Kungliga Tekniska Högskolan (1)
Chalmers tekniska högskola (1)
visa färre...
Språk
Engelska (47)
Svenska (1)
Tyska (1)
Odefinierat språk (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (19)
Naturvetenskap (18)
Lantbruksvetenskap (7)
Samhällsvetenskap (4)
Teknik (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy