SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Malina Martin) "

Sökning: WFRF:(Malina Martin)

  • Resultat 1-10 av 124
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Acosta, Stefan, et al. (författare)
  • L-lactate after embolization of the superior mesenteric artery
  • 2007
  • Ingår i: Journal of Surgical Research. - Orlando, Fla. : Elsevier BV. - 1095-8673 .- 0022-4804. ; 143:2, s. 320-328
  • Tidskriftsartikel (refereegranskat)abstract
    • Background. Plasma markers for intestinal ischemia have not proven to be accurate. The value of L-lactate is unclear. Experimental models based on open surgery confound the effects of surgical trauma with that of ischemia. The aim was to create an endovascular model for acute superior mesenteric artery thromboembolism, and then to study L-lactate and lactate dehydrogenase (LD) activity in plasma and peritoneal fluid in pigs with extensive, high-grade intestinal ischemia. Materials and methods. Nine pigs underwent full superior mesenteric artery embolization with 4 h of intended intestinal ischemia, whereas six were control animals. Sampling of central venous and arterial blood was performed throughout the experiment, ending with laparotomy to collect peritoneal fluid and segmental intestinal biopsies. A pathologist, blinded to the performed interventions, graded the ischemic lesions. Results. There were no differences in plasma L-lactate (P = 0.61) or LD activity levels (P = 0.69), measured at different time points from baseline to end of study, between animals with extensive, high-grade intestinal ischemia and sham. Intraperitoneal L-Lactate (P = 0.005) and LD activity (P = 0.018) levels were elevated compared with sham. There were differences in grades of ischemia in the duodenum (P = 0.003), small intestine (P < 0.001), proximal (P < 0.001), and sigmoid (P = 0.032) colon between experimental animals and sham. The grade of small bowel ischemia (n = 15) correlated to intraperitoneal fluid L-lactate (r = 0.80; P < 0.001) and LD activity levels (r = 0.72; P = 0.003). Conclusions. This endovascular study in a porcine model showed that L-lactate and LD activity levels in peritoneal fluid, not in plasma, reflect intestinal ischemia. The study suggests that plasma L-lactate not is a useful early marker in patients with suspicion of intestinal ischemia. (c) 2007 Elsevier Inc. All rights reserved.
  •  
2.
  • Djavani Gidlund, Khatereh (författare)
  • Intra-abdominal Hypertension and Colonic Hypoperfusion after Abdominal Aortic Aneurysm Repair
  • 2011
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Colonic ischaemia (CI), Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are devastating complications after abdominal aortic aneurysm (AAA) surgery. The aims of this thesis were to study the incidence and clinical consequences of IAH/ACS and the association between CI and intra-abdominal pressure (IAP) among patients undergoing OR for ruptured AAA (rAAA), to compare extraluminal pHi monitoring, with standard intra-luminal monitoring among patients operated on for AAA, and to study the frequency and clinical consequences of IAH/ACS after endovascular repair (EVAR) for rAAA. The incidence of ACS was 26% in a retrospective study of 27 patients undergoing OR for rAAA. Consensus definitions on IAH/ACS were appropriate for patients after OR for rAAA: 78% (7/9) of patients with IAH grade III or IV developed organ failure and all patients who developed CI had some degree of IAH. Active fluid resuscitation treating hypovolaemia to avoid CI may partly cause IAH. The association between CI and IAP was investigated in a prospective study on 29 patients operated on for rAAA, 86% (25/29) were treated for hypovolaemia and ten (34%) had both IAH and CI. Since monitoring colonic perfusion is very important and there is no ideal method, a new technique, extraluminal colonic tonometry to detect colonic perfusion was compared with standard intraluminal tonometry. Although, this new method was not able to determine the severity of ischaemia it may serve as a screening test. EVAR of rAAA is feasible and patients may benefit from this less invasive procedure. Of 29 patients treated with this technique, 10% developed ACS, and all patients except one with preoperative shock developed some degree of IAH. In conclusion, IAP/ACS is common after both OR and EVAR for rAAA, and is associated with adverse outcome. Monitoring IAP and colonic perfusion with timely intervention may improve outcome.
  •  
3.
  •  
4.
  •  
5.
  • Koning, Olivier H. J., et al. (författare)
  • Fluoroscopic Roentgen stereophotogrammetric analysis (FRSA) to study three-dimensional stent graft dynamics
  • 2009
  • Ingår i: Journal of Vascular Surgery. - : Elsevier BV. - 1097-6809 .- 0741-5214. ; 50:2, s. 407-412
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the clinical feasibility of fluoroscopic Roentgen stereophotogrammetric analysis (FRSA), a validated method to quantify, real time three-dimensional (3D) dynamic motion of stent grafts and the first clinical results after abdominal and thoracic endovascular repair (EVAR). Stent graft motion was measured at 30 (stereo) frames per second, during the cardiac cycle and in the patient after abdominal EVAR, due to respiratory action. Translational motions of the center of mass, diameter change, and rotational and axial motion could be measured. Quantification of 3D motion was not available until now. FRSA can provide crucial information on the forces exerted oil stent grafts and will, therefore, provide essential information for improvements in stent graft design. (J Vasc Surg 2009;50:407-12.)
  •  
6.
  •  
7.
  • Malina, Martin, et al. (författare)
  • Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?
  • 1998
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 5:4, s. 310-317
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. METHODS: Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. RESULTS: The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p < 0.001. Both hooks and barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. CONCLUSIONS: Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.
  •  
8.
  • Malina, Martin, et al. (författare)
  • Endovascular healing is inadequate for fixation of Dacron stent-grafts in human aortoiliac vessels
  • 2000
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 19:1, s. 5-11
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: migration and kinking of stent-grafts can occur late after endovascular aneurysm repair. It is unknown if endovascular grafts incorporate enough to be permanently anchored. In this report, healing of aortic stent-grafts was assessed in humans. PATIENTS AND METHODS: we retrieved 23 Dacron stent-grafts from patients treated for an aortic aneurysm since 1993. Twelve stent-grafts were explanted at late conversion to open repair and 11 at autopsy. The deaths were unrelated to graft fixation. The median age of the patients was 74 years (IQR 55-84 years) and the grafts were explanted 9 months (1-31 months) after insertion. Microscopic slides were prepared by conventional techniques or by cutting and grinding arterial specimens embedded in plastic with the stent-grafts in situ. RESULTS: the stent-grafts detached readily from the native arteries at surgery or autopsy, except when the stents had hooks or barbs which engaged the vessel wall. A space filled with poorly organised blood components persisted between the graft and the aortic wall 2.5 years after implantation. No firm incorporation of the grafts was observed proximally in the aneurysm neck or distally in the iliac segment. A friable neo-intimal layer covered parts of the luminal aspect of the grafts. CONCLUSIONS: endovascular healing provides poor fixation of Dacron stent-grafts in humans. At present, fixation relies on the mechanical properties of the stent-grafts.
  •  
9.
  • Malina, Martin, et al. (författare)
  • Late aortic arch perforation by graft-anchoring stent: complication of endovascular thoracic aneurysm exclusion
  • 1998
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 5:3, s. 274-277
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To describe a fatal case of late aortic perforation by an endograft-anchoring stent. METHODS AND RESULTS: A 69-year-old woman presented 2 years after thoracoabdominal aneurysm repair with a 9-cm dilatation of the descending thoracic aorta proximal to the conventional aortic graft. A 38-mm Dacron graft with multiple Gianturco Z-stents sutured inside was placed transluminally across the aortic arch such that part of the uncovered portion of the proximal stent was partially across the left subclavian orifice. Four months later, the patient died from massive hemorrhage. Autopsy showed that the uncovered portion of the proximal stent had perforated the aortic arch. CONCLUSIONS: This case stresses the need for low-profile stent-grafts and smaller, more flexible introducer systems. Anchoring stents must be flexible, less traumatic, and strong enough to create a watertight seal even in tortuous vessels. To avoid aortic arch damage by thoracic stent-grafts, the proximal stent should be fully covered by the fabric.
  •  
10.
  • Resch, Tim, et al. (författare)
  • The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study
  • 2000
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 20:2, s. 190-195
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: to study the proximal fixation of different aortic stent grafts in comparison to a hand-sewn anastomosis. DESIGN: experimental study. MATERIAL: the infrarenal aorta of 16 human cadavers were exposed, left in situ and transected 3 cm above the aortic bifurcation to mimic an infrarenal aortic neck. Stent grafts were deployed through a sheath 5 cm into the aorta. Ancure, Talent, Vanguard, Zenith and a Palmaz based stent graft were assessed. In addition a polyester graft was anastomosed to the aorta by running sutures. Distal force was applied to the grafts in increments of 0.5 Newton until the stent grafts were completely dislodged from the aorta. The displacement force (DF) was thereby determined. RESULTS: a force of 150 N (140-160) applied to the hand-sewn graft resulted in tearing of the aorta, without breakage of the sutures. The median displacement force was for Talent 4.5 N (1.3-5.5), Vanguard 9.0 N (3. 5-12), Ancure 12.5 N (12-14), Zenith 24 N (23-26.5) and Palmaz 25 N (17-25). Ballooning the stent after deployment improved fixation in some cases. CONCLUSIONS: a sutured anastomosis fixates a graft better than any stent design tested. Hooks and barbs improve the fixation of self-expandable stents. Balloon dilatation of the proximal stent after deployment might increase fixation further. Balloon expandable stents seem to provide good fixation without the use of hooks and barbs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 124

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy