SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Malusek Alexandr) "

Sökning: WFRF:(Malusek Alexandr)

  • Resultat 1-10 av 37
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Björkman, Ann-Sofi, et al. (författare)
  • Spectral photon-counting CT: Image quality evaluation using a metal-containing bovine bone specimen
  • 2023
  • Ingår i: European Journal of Radiology. - : ELSEVIER IRELAND LTD. - 0720-048X .- 1872-7727. ; 168
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To find the optimal imaging parameters for a photon-counting detector CT (PCD-CT) and to compare it to an energy-integrating detector CT (EID-CT) in terms of image quality and metal artefact severity using a metal-containing bovine knee specimen. Methods: A bovine knee with a stainless-steel plate and screws was imaged in a whole-body research PCD-CT at 120 kV and 140 kV and in an EID dual-source CT (DSCT) at Sn150 kV and 80/Sn150 kV. PCD-CT virtual monoenergetic 72 and 150 keV images and EID-CT images processed with and without metal artefact reduction algorithms (iMAR) were compared. Four radiologists rated the visualisation of bony structures and metal artefact severity. The Friedman test and Wilcoxon signed-rank test with Bonferronis correction were used. P-values of <= 0.0001 were considered statistically significant. Distributions of HU values of regions of interest (ROIs) in artefact-affected areas were analysed.Results: PCD-CT 140 kV 150 keV images received the highest scores and were significantly better than EID-CT Sn150 kV images. PCD-CT 72 keV images were rated significantly lower than all the others. HU-value variation was larger in the 120 kV and the 72 keV images. The ROI analysis revealed no large difference between scanners regarding artefact severity.Conclusion: PCD-CT 140 kV 150 keV images of a metal-containing bovine knee specimen provided the best image quality. They were superior to, or as good as, the best EID-CT images; even without the presumed advantage of tin filter and metal artefact reduction algorithms. PCD-CT is a promising method for reducing metal artefacts.
  •  
2.
  • Jeuthe, Julius, et al. (författare)
  • Semi-Automated 3D Segmentation of Pelvic Region Bones in CT Volumes for the Annotation of Machine Learning Datasets
  • 2021
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press. - 0144-8420 .- 1742-3406. ; 195:3-4, s. 172-176
  • Tidskriftsartikel (refereegranskat)abstract
    • Automatic segmentation of bones in computed tomography (CT) images is used for instance in beam hardening correction algorithms where it improves the accuracy of resulting CT numbers. Of special interest are pelvic bones, which—because of their strong attenuation—affect the accuracy of brachytherapy in this region. This work evaluated the performance of the JJ2016 algorithm with the performance of MK2014v2 and JS2018 algorithms; all these algorithms were developed by authors. Visual comparison, and, in the latter case, also Dice similarity coefficients derived from the ground truth were used. It was found that the 3D-based JJ2016 performed better than the 2D-based MK2014v2, mainly because of the more accurate hole filling that benefitted from information in adjacent slices. The neural network-based JS2018 outperformed both traditional algorithms. It was, however, limited to the resolution of 1283 owing to the limited amount of memory in the graphical processing unit (GPU).
  •  
3.
  • Kardell, Martin, et al. (författare)
  • AUTOMATIC SEGMENTATION OF PELVIS FOR BRACHYTHERAPYOF PROSTATE
  • 2016
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 169:1-4, s. 398-404
  • Tidskriftsartikel (refereegranskat)abstract
    • Advanced model-based iterative reconstruction algorithms in quantitative computed tomography (CT) perform automatic segmentation of tissues to estimate material properties of the imaged object. Compared with conventional methods, these algorithms may improve quality of reconstructed images and accuracy of radiation treatment planning. Automatic segmentation of tissues is, however, a difficult task. The aim of this work was to develop and evaluate an algorithm that automatically segments tissues in CT images of the male pelvis. The newly developed algorithm (MK2014) combines histogram matching, thresholding, region growing, deformable model and atlas-based registration techniques for the segmentation of bones, adipose tissue, prostate and muscles in CT images. Visual inspection of segmented images showed that the algorithm performed well for the five analysed images. The tissues were identified and outlined with accuracy sufficient for the dual-energy iterative reconstruction algorithm whose aim is to improve the accuracy of radiation treatment planning in brachytherapy of the prostate.
  •  
4.
  • Kaveckyte, Vaiva, 1991- (författare)
  • Development of Experimental Brachytherapy Dosimetry Using Monte Carlo Simulations for Detector Characterization
  • 2021
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Brachytherapy (BT) is a type of interventional radiotherapy that is advantageous due to high absorbed dose conformity and possibility to deliver high dose in few fractions. It is often used for prostate and gynecological tumors as monotherapy or a boost alongside external beam radiotherapy (EBRT). However, there is a number of things that can compromise treatment delivery, starting from incorrect source data in a treatment planning system to malfunctioning of a treatment delivery unit. None of the established quality assurance (QA) procedures emulate treatment delivery where the planned dose could be compared with the experimentally determined value. While such practices are employed in EBRT, BT suffers from the lack of detectors that would be water-equivalent and convenient to use for regular measurements. First-choice thermoluminescence dosimeters are water-equivalent but have passive readout. Sporadic attempts to use other detectors have not led to any established practices at clinical sites. Stepping ahead, the safety of treatment delivery could be further evaluated using real-time in vivo dosimetry. If detectors were characterized with high-accuracy, a reliable error detection level could be set to terminate treatments if needed. Contrary to in-phantom QA, there are detectors suitable for such applications but their characterization is incomplete. In this thesis we address both problems.Focusing on high-dose-rate 192Ir remote afterloading treatments, which are among the most common in BT, we investigate and propose a direct readout synthetic diamond detector for in-phantom QA of treatment units. The detector was designed for small-field high-energy EBRT dosimetry but our findings demonstrate its suitability for BT dosimetry. Additionally, due to detector calibration with traceability to absorbed dose to water primary standards of high-energy photon beams and combined experimental and Monte Carlo (MC) characterization, the uncertainties in absorbed dose to water were comparable to passive readout detectors and lower than for other direct readout detectors. We complemented detector investigation with a theoretical study on diamond material properties and which values (mass density, mean excitation energy, number of conduction electrons per atom) shall be used for the most faithful description of ionizing radiation interactions in diamond for MC simulations and calculations of mass electronic stopping power. The findings improve diamond dosimetry accuracy, and subsequently, experimental dosimetry of not only BT but all radiotherapy beam qualities where the detectors are used.Aiming to further contribute to experimental BT dosimetry, we focused on high atomic number inorganic scintillators used for in vivo dosimetry: ZnSe, CsI, and Al2O3. These are already existing dosimeters exhibiting promising luminescence properties, but until now, their investigation has been solely experimental. MC simulations are not subject to detector positioning uncertainties which are high due to steep dose gradients and other detector response artifacts, thus we used the method to investigate the absorbed-dose energy response of detectors, its dependence on radial distance and polar angles, scatter conditions, as well as detector design. We clarified how error-prone high atomic number detector characterization might be if experimental and MC methods are not combined. Both have certain limitations and have to complement each other.Though the thesis addresses two different types of detectors for two different applications, the underlying theme is to understand the detector at hand. The use of MC simulations allowed introducing a new synthetic diamond detector into BT field and improving accuracy of in vivo dosimetry systems using inorganic scintillators. We also raised awareness to the lack of unified detector calibration and characterization practice in BT dosimetry.
  •  
5.
  • Kaveckyte, Vaiva, et al. (författare)
  • Investigation of a synthetic diamond detector response in kilovoltage photon beams
  • 2020
  • Ingår i: Medical physics (Lancaster). - : Wiley-Blackwell Publishing Inc.. - 0094-2405 .- 2473-4209. ; 47:3, s. 1268-1279
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose An important characteristic of radiation dosimetry detectors is their energy response which consists of absorbed-dose and intrinsic energy responses. The former can be characterized using Monte Carlo (MC) simulations, whereas the latter (i.e., detector signal per absorbed dose to detector) is extracted from experimental data. Such a characterization is especially relevant when detectors are used in nonrelative measurements at a beam quality that differs from the calibration beam quality. Having in mind the possible application of synthetic diamond detectors (microDiamond PTW 60019, Freiburg, Germany) for nonrelative dosimetry of low-energy brachytherapy (BT) beams, we determined their intrinsic and absorbed-dose energy responses in 25-250 kV beams relative to a Co-60 beam, which is usually the reference beam quality for detector calibration in radiotherapy. Material and Methods Three microDiamond detectors and, for comparison, two silicon diodes (PTW 60017) were calibrated in terms of air-kerma free in air in six x-ray beam qualities (from 25 to 250 kV) and in terms of absorbed dose to water in a Co-60 beam at the national metrology laboratory in Sweden. The PENELOPE/penEasy MC radiation transport code was used to calculate the absorbed-dose energy response of the detectors (modeled based on blueprints) relative to air and water depending on calibration conditions. The MC results were used to extract the relative intrinsic energy response of the detectors from the overall energy response. Measurements using an independent setup with a single ophthalmic BEBIG I25.S16 I-125 BT seed (effective photon energy of 28 keV) were used as a qualitative check of the extracted intrinsic energy response correction factors. Additionally, the impact of the thickness of the active volume as well as the presence of extra-cameral components on the absorbed-dose energy response of a microDiamond detector was studied using MC simulations. Results The relative intrinsic energy response of the microDiamond detectors was higher by a factor of 2 in 25 and 50 kV beams compared to the Co-60 beam. The variation in the relative intrinsic energy response of silicon diodes was within 10% over the investigated photon energy range. The use of relative intrinsic energy response correction factors improved the agreement among the absorbed dose to water values determined using microDiamond detectors and silicon diodes, as well as with the TG-43 formalism-based calculations for the I-125 seed. MC study of microDiamond detector design features provided a possible explanation for inter-detector response variation at low-energy photon beams by differences in the effective thickness of the active volume. Conclusions MicroDiamond detectors had a non-negligible variation in the relative intrinsic energy response (factor of 2) which was comparable to that in the absorbed-dose energy response relative to water at low-energy photon beams. Silicon diodes, in contrast, had an absorbed-dose energy dependence on photon energy that varied by a factor of 6, whereas the intrinsic energy dependence on beam quality was within 10%. It is important to decouple these two responses for a full characterization of detector energy response especially when the user and reference beam qualities differ significantly, and MC alone is not enough.
  •  
6.
  • Kaveckyte, Vaiva, et al. (författare)
  • Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate Ir-192 brachytherapy sources
  • 2018
  • Ingår i: Medical physics (Lancaster). - : WILEY. - 0094-2405 .- 2473-4209. ; 45:1, s. 429-437
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Experimental dosimetry of high-dose-rate (HDR) Ir-192 brachytherapy (BT) sources is complicated due to high dose and dose-rate gradients, and softening of photon energy spectrum with depth. A single crystal synthetic diamond detector microDiamond (PTW 60019, Freiburg, Germany) has a small active volume, high sensitivity, direct readout, and nearly water-equivalent active volume. The purpose of this study was to evaluate the suitability of microDiamond detectors for the determination of absorbed dose to water around HDR Ir-192 BT sources. Three microDiamond detectors were used, allowing for the comparison of their properties. Methods: In-phantom measurements were performed using microSelectron and VariSource iX HDR Ir-192 BT treatment units. Their treatment planning systems (TPSs), Oncentra (v. 4.3) and BrachyVision (v. 13.6), respectively, were used to create irradiation plans for a cubic PMMA phantom with the microDiamond positioned at one of three source-to-detector distances (SDDs) (1.5, 2.5, and 5.5 cm) at a time. The source was stepped in increments of 0.5 cm over a total length of 6 cm to yield absorbed dose of 2 Gy at the nominal reference-point of the detector. Detectors were calibrated in Co-60 beam in terms of absorbed dose to water, and Monte Carlo (MC) calculated beam quality correction factors were applied to account for absorbed-dose energy dependence. Phantom correction factors were applied to account for differences in dimensions between the measurement phantom and a water phantom used for absorbed dose calculations made with a TPS. The same measurements were made with all three of the detectors. Additionally, dose-rate dependence and stability of the detectors were evaluated in Co-60 beam. Results: The percentage differences between experimentally determined and TPS-calculated absorbed doses to water were from -1.3% to +2.9%. The values agreed to within experimental uncertainties, which were from 1.9% to 4.3% (k = 2) depending on the detector, SDD and treatment delivery unit. No dose-rate or intrinsic energy dependence corrections were applied. All microDiamonds were comparable in terms of preirradiation dose, stability of the readings and energy response, and showed a good agreement. Conclusions: The results indicate that the microDiamond is potentially suitable for the determination of absorbed dose to water around HDR Ir-192 BT sources and may be used for independent verification of TPSs calculations, as well as for QA measurements of HDR Ir-192 BT treatment delivery units at clinical sites. (C) 2017 American Association of Physicists in Medicine
  •  
7.
  • Klintström, Benjamin, et al. (författare)
  • Photon-counting detector CT and energy-integrating detector CT for trabecular bone microstructure analysis of cubic specimens from human radius
  • 2022
  • Ingår i: European radiology experimental. - : Springer Nature. - 2509-9280. ; 6:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background As bone microstructure is known to impact bone strength, the aim of this in vitro study was to evaluate if the emerging photon-counting detector computed tomography (PCD-CT) technique may be used for measurements of trabecular bone structures like thickness, separation, nodes, spacing and bone volume fraction. Methods Fourteen cubic sections of human radius were scanned with two multislice CT devices, one PCD-CT and one energy-integrating detector CT (EID-CT), using micro-CT as a reference standard. The protocols for PCD-CT and EID-CT were those recommended for inner- and middle-ear structures, although at higher mAs values: PCD-CT at 450 mAs and EID-CT at 600 (dose equivalent to PCD-CT) and 1000 mAs. Average measurements of the five bone parameters as well as dispersion measurements of thickness, separation and spacing were calculated using a three-dimensional automated region growing (ARG) algorithm. Spearman correlations with micro-CT were computed. Results Correlations with micro-CT, for PCD-CT and EID-CT, ranged from 0.64 to 0.98 for all parameters except for dispersion of thickness, which did not show a significant correlation (p = 0.078 to 0.892). PCD-CT had seven of the eight parameters with correlations rho > 0.7 and three rho > 0.9. The dose-equivalent EID-CT instead had four parameters with correlations rho > 0.7 and only one rho > 0.9. Conclusions In this in vitro study of radius specimens, strong correlations were found between trabecular bone structure parameters computed from PCD-CT data when compared to micro-CT. This suggests that PCD-CT might be useful for analysing bone microstructure in the peripheral human skeleton.
  •  
8.
  • Kubancak, J., et al. (författare)
  • Liulin silicon semiconductor spectrometers as cosmic ray monitors at  the high mountain observatories Jungfraujoch and Lomnický štít
  • 2014
  • Ingår i: Journal of Instrumentation. - : Institute of Physics Publishing (IOPP). - 1748-0221. ; 9:P07018
  • Tidskriftsartikel (refereegranskat)abstract
    • Currently, most cosmic ray data are obtained by detectors on satellites, aircraft, high-altitude balloons and ground (neutron monitors). In our work, we examined whether Liulin semiconductor spectrometers (simple silicon planar diode detectors with spectrometric properties) located at high mountain observatories could contribute new information to the monitoring of cosmic rays by analyzing data from selected solar events between 2005 and 2013. The decision thresholds and detection limits of these detectors placed at Jungfraujoch (Switzerland; 3475 m a.s.l.; vertical cut-off rigidity 4.5 GV) and Lomnicky. stit (Slovakia; 2633 m a.s.l.; vertical cut-off rigidity 3.84 GV) highmountain observatories were determined. The data showed that only the strongest variations of the cosmic ray flux in this period were detectable. The main limitation in the performance of these detectors is their small sensitive volume and low sensitivity of the PIN photodiode to neutrons.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 37
Typ av publikation
tidskriftsartikel (23)
konferensbidrag (7)
rapport (3)
doktorsavhandling (2)
annan publikation (1)
bokkapitel (1)
visa fler...
visa färre...
Typ av innehåll
refereegranskat (30)
övrigt vetenskapligt/konstnärligt (7)
Författare/redaktör
Malusek, Alexandr (28)
Alm Carlsson, Gudrun (20)
Sandborg, Michael (10)
Sandborg, Michael, 1 ... (10)
Magnusson, Maria (9)
Alm Carlsson, Gudrun ... (8)
visa fler...
Malusek, Alexandr, 1 ... (8)
Carlsson Tedgren, Ås ... (6)
Magnusson, Maria, 19 ... (4)
Carlsson Tedgren, Ås ... (3)
Henriksson, Lilian (3)
Helmrot, Ebba (2)
Williamson, Jeffrey (2)
Benmakhlouf, Hamza (2)
Kaveckyte, Vaiva (2)
Jeuthe, Julius (2)
Sánchez, José Carlos ... (2)
Dahlqvist Leinhard, ... (1)
Lundberg, Peter, 195 ... (1)
Kudela, K. (1)
Klintström, Benjamin (1)
Karlsson, Mattias (1)
Persson, Anders (1)
Smedby, Örjan, Profe ... (1)
Uvdal, Kajsa, 1961- (1)
Larsson, Peter (1)
Koskinen, Seppo (1)
Persliden, Jan (1)
Ambrozova, I. (1)
Pachnerova Brabcová, ... (1)
Davidkova, M. (1)
Persson, Linda (1)
Gauffin, Håkan (1)
Cohen, L (1)
Moreno, Rodrigo, 197 ... (1)
Klintström, Eva (1)
Woisetschläger, Misc ... (1)
Björkman, Ann-Sofi (1)
Dahlström, Nils, 196 ... (1)
Ullman, Gustaf (1)
Langer, R (1)
Grindborg, J-E (1)
Hedtjärn, Håkan (1)
Magnusson Seger, Mar ... (1)
Eriksson, Peter, 198 ... (1)
Dance, David R. (1)
Örtenberg, Alexander (1)
Kardell, Martin (1)
Kaveckyte, Vaiva, 19 ... (1)
Carlsson Tedgren, Ås ... (1)
visa färre...
Lärosäte
Linköpings universitet (37)
Karolinska Institutet (8)
Kungliga Tekniska Högskolan (1)
Chalmers tekniska högskola (1)
Språk
Engelska (37)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (15)
Teknik (7)
Naturvetenskap (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy