SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Man Sumche) "

Sökning: WFRF:(Man Sumche)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Lindow, Thomas, et al. (författare)
  • Diagnostic Accuracy of the Electrocardiographic Decision Support – Myocardial Ischaemia (EDS-MI) Algorithm in Detection of Acute Coronary Occlusion
  • 2020
  • Ingår i: European Heart Journal: Acute Cardiovascular Care. - : Oxford University Press (OUP). - 2048-8734 .- 2048-8726. ; 9:S1, s. 13-25
  • Tidskriftsartikel (refereegranskat)abstract
    • Electrocardiographic Decision Support - Myocardial Ischaemia (EDS-MI) is a graphical decision support for detection and localization of acute transmural ischaemia. A recent study indicated that EDS-MI performs well for detection of acute transmural ischaemia. However, its performance has not been tested in patients with non-ischaemic ST-deviation. We aimed to optimize the diagnostic accuracy of EDS-MI in patients with verified acute coronary occlusion as well as patients with non-ischaemic ST deviation and compare its performance with STEMI criteria. We studied 135 patients with non-ischaemic ST deviation (perimyocarditis, left ventricular hypertrophy, takotsubo cardiomyopathy and early repolarization) and 117 patients with acute coronary occlusion. In 63 ischaemic patients, the extent and location of the ischaemic area (myocardium at risk) was assessed by both cardiovascular magnetic resonance imaging and EDS-MI. Sensitivity and specificity of ST elevation myocardial infarction criteria were 85% (95% confidence interval (CI) 77, 90) and 44% (95% CI 36, 53) respectively. Using EDS-MI, sensitivity and specificity increased to 92% (95% CI 85, 95) and 81% (95% CI 74, 87) respectively (p=0.035 and p<0.001). Agreement was strong (83%) between cardiovascular magnetic resonance imaging and EDS-MI in localization of ischaemia. Mean myocardium at risk was 32% (± 10) by cardiovascular magnetic resonance imaging and 33% (± 11) by EDS-MI when the estimated infarcted area according to Selvester QRS scoring was included in myocardium at risk estimation. In conclusion, EDS-MI increases diagnostic accuracy and may serve as an automatic decision support in the early management of patients with suspected acute coronary syndrome. The added clinical benefit in a non-selected clinical chest pain population needs to be assessed.
  •  
3.
  • Lindow, Thomas, et al. (författare)
  • The Olson method for detection of acute myocardial ischemia in patients with coronary occlusion
  • 2017
  • Ingår i: Journal of Electrocardiology. - : Elsevier BV. - 0022-0736. ; 50:1, s. 74-81
  • Tidskriftsartikel (refereegranskat)abstract
    • An automated ECG-based method may provide diagnostic support in the management of patients with acute coronary syndrome. The Olson method has previously proved to accurately identify the culprit artery in patients with acute coronary occlusion. Methods The Olson method was applied to 360 patients without acute myocardial ischemia and 52 patients with acute coronary occlusion. Results This study establishes the normal variation of the Olson wall scores in patients without acute myocardial ischemia, which provides the basis for implementation of the Olson method for triage of patients with acute coronary syndrome. All patients with acute occlusion had Olson wall scores above the upper limit of normal. Conclusion The Olson method can be used for ischemia detection with very high sensitivity. Future studies are needed to explore specificity in patients with non-ischemic ST elevation.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy