SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Mangialardi N.) "

Sökning: WFRF:(Mangialardi N.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brunkwall, J., et al. (författare)
  • Endovascular Repair of Acute Uncomplicated Aortic Type B Dissection Promotes Aortic Remodelling: 1 Year Results of the ADSORB Trial
  • 2014
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 48:3, s. 285-291
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Uncomplicated acute type B aortic dissection (AD) treated conservatively has a 10% 30-day mortality and up to 25% need intervention within 4 years. In complicated AD, stent grafts have been encouraging. The aim of the present prospective randomised trial was to compare best medical treatment (BMT) with BMT and Gore TAG stent graft in patients with uncomplicated AD. The primary endpoint was a combination of incomplete/no false lumen thrombosis, aortic dilatation, or aortic rupture at 1 year. Methods: The AD history had to be less than 14 days, and exclusion criteria were rupture, impending rupture, malperfusion. Of the 61 patients randomised, 80% were DeBakey type IIIB. Results: Thirty-one patients were randomised to the BMT group and 30 to the BMT+TAG group. Mean age was 63 years for both groups. The left subclavian artery was completely covered in 47% and in part in 17% of the cases. During the first 30 days, no deaths occurred in either group, but there were three crossovers from the BMT to the BMT TAG group, all due to progression of disease within 1 week. There were two withdrawals from the BMT+TAG group. At the 1-year follow up there had been another two failures in the BMT group: one malperfusion and one aneurysm formation (p = .056 for all). One death occurred in the BMT TAG group. For the overall endpoint BMT+TAG was significantly different from BMT only (p < .001). Incomplete false lumen thrombosis, was found in 13 (43%) of the TAG+BMT group and 30 (97%) of the BMT group (p < .001). The false lumen reduced in size in the BMT+TAG group (p < .001) whereas in the BMT group it increased. The true lumen increased in the BMT TAG (p < .001) whereas in the BMT group it remained unchanged. The overall transverse diameter was the same at the beginning and after 1 year in the BMT group (42.1 mm), but in the BMT+TAG it decreased (38.8 mm; p = .062). Conclusions: Uncomplicated AD can be safely treated with the Gore TAG device. Remodelling with thrombosis of the false lumen and reduction of its diameter is induced by the stent graft, but long term results are needed. (C) 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
  •  
2.
  • Pecoraro, F, et al. (författare)
  • Predilation technique with balloon angioplasty to facilitate percutaneous groin access of large size sheath through scar tissue
  • 2017
  • Ingår i: Vascular. - : SAGE Publications. - 1708-539X .- 1708-5381. ; 25:4, s. 396-401
  • Tidskriftsartikel (refereegranskat)abstract
    • Percutaneous remote access for endovascular aortic repair is an advantageous alternative to open access. Previous surgery in the femoral region and the presence of synthetic vascular grafts in the femoral/iliac arteries represent major limitations to percutaneous remote access. The aim of this study was to evaluate an original technique used for enabling percutaneous remote access for thoracic or abdominal endovascular aortic repair in patients with scar tissue and/or a vascular graft in the groin. Methods Twenty-five consecutive patients with a thoracic (11/25; 44%) or an aortic aneurysm (14/25; 66%) and with a synthetic vascular graft in the groin (16/25; 64%) or a redo groin access (9/25; 36%) were managed through the percutaneous remote access. In all patients, a percutaneous transluminal angioplasty balloon was used to predilate the scar tissue and the femoral artery or the synthetic vascular graft after preclosing (ProGlide®; Abbott Vascular, Santa Clara, CA, USA). In 10 patients, requiring a 20 Fr sheath, a 6 mm percutaneous transluminal angioplasty balloon was used; and in the remaining 15, requiring a 24 Fr sheath, an 8 mm percutaneous transluminal angioplasty balloon. Preclosing was exclusively performed using ProGlide®. Mean follow-up was 15 months. Results In all cases, stent-graft deployment was successful. There was one surgical conversion (4%; 1/25) due to bleeding from a femoral anastomosis. Two cases required additional percutaneous maneuvers (postclosing with another system in one patient and endoluminal shielding with stent-graft in the other patient). No pseudoaneurysm or access complication occurred during the follow-up. Conclusions Percutaneous access in redo groins with scar tissue and/or synthetic vascular graft using ultrasound-guided punction, preclosing with ProGlide® system and predilation with percutaneous transluminal angioplasty balloon to introduce large size sheath as used for endovascular aortic repair showed to be feasible, safe and with few local complications.
  •  