SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Mauritzson N) "

Sökning: WFRF:(Mauritzson N)

  • Resultat 1-10 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Albin, Maria, et al. (författare)
  • Acute myeloid leukemia and clonal chromosome aberrations in relation to past exposure to organic solvents
  • 2000
  • Ingår i: Scandinavian Journal of Work, Environment and Health. - 0355-3140. ; 26:6, s. 482-491
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: The effects of occupational and leisure-time exposures on the risk of acute myeloid leukemia (AML) were investigated with emphasis on clonal chromosome aberrations (CCA) and morphological subtypes. METHODS: Consecutively diagnosed cases of AML (N=333) and 1 population referent per case were retrospectively included in the study. Information on worktasks, companies, and leisure-time activities was obtained with telephone interviews. Exposure probability and intensity were assessed by occupational hygienists. Associations were evaluated with logistic regression. RESULTS: Exposure to organic solvents was associated with an increased risk of AML [low exposure: OR 1.5 (95% confidence interval (95% CI) 1.0-2.3, moderate-high exposure: OR 2.3 (95% CI 1.0-5.0)]. For exposure to solvents, but not to benzene, the OR was 1.2 (95% CI 0.69-2.0) for "low" and 2.7 (95% CI 1.0-7.3) for "moderate-high" exposure. The observed effects increased with intensity and duration of exposure. The estimated effects were higher for patients >60 years of age at the time of diagnosis. The effect of exposure to organic solvents was not differential with regard to morphology [except possibly erythroleukemia: OR 4.2, 95% CI 1.0-17 or the presence of CCA in general]. No increased risk for AML with complex CCA or with total or partial losses of chromosomes 5 or 7 were observed, but a higher risk was found for AML with trisomy 8 (OR 11, 95% CI 2.7-42) as the sole aberration. CONCLUSIONS: Exposure to organic solvents was associated with an increased risk of AML. This association was not due to benzene exposure alone and may be modified by age. Furthermore, specific associations with trisomy 8, and possibly also erythroleukemia, were suggested.
  •  
2.
  • Boyd, L., et al. (författare)
  • Simulation of the response of the Solid State Neutron Detector for the European Spallation Source
  • 2021
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 998
  • Tidskriftsartikel (refereegranskat)abstract
    • The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interactions of thermal neutrons and ionising radiation in the 6Li-doped scintillating glass of the detector, the production of scintillation light and the transport of optical, scintillation photons through the scintillator, en route to the photocathode of the attached multi-anode photomultiplier. Factors which affect the optical-photon transport, such as surface finish, pixelation of the glass sheet, provision of a front reflector and optical coupling media are compared. Predictions of the detector response are compared with measurements made with neutron and gamma-ray sources, a collimated alpha source and finely collimated beams of 2.5 MeV protons and deuterons.
  •  
3.
  • Frost, R. J. W., et al. (författare)
  • A compact accelerator driven neutron source at the Applied Nuclear Physics Laboratory, Lund University
  • 2023
  • Ingår i: EPJ TECHNIQUES AND INSTRUMENTATION. - : Springer Nature. - 2195-7045. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The Applied Nuclear Physics Group at Lund University has constructed a CANS (Compact Accelerator-driven Neutron Source). The CANS is based around a 3 MV, single-ended, Pelletron accelerator, which is used to impinge a 2.8 MeV deuterium beam into a beryllium target. The anticipated neutron production will be on the order of 10(10) n/s in 4 pi sr, with future upgrades expected to increase neutron production to 10(11) n/s. Neutron energy will be up to 9 MeV with peak emission at similar to 5 MeV. Shielding and moderation will be provided by a large water tank surrounding the target, with exit ports to allow moderated neutrons to be directed to experiments. The thermal-neutron flux at the exit of the extraction ports is anticipated to be up to 10(6) n/cm(2)/s. The CANS will be used to forward the activities of the group in the area of neutron-activation analysis, in addition to a broader range of neutron related applications.
  •  
4.
  • Maulerova, V., et al. (författare)
  • Vanadium-based neutron beam monitor
  • 2020
  • Ingår i: Physical Review Accelerators and Beams. - 2469-9888. ; 23:7
  • Tidskriftsartikel (refereegranskat)abstract
    • A prototype quasiparasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard He3 proportional counters is conceptualized, designed, simulated, calibrated, and commissioned. The European Spallation Source designed to deliver the highest integrated neutron flux originating from a pulsed source is currently under construction in Lund, Sweden. The effort to investigate a vanadium-based neutron beam monitor was triggered by a list of requirements for beam monitors permanently placed in the ESS neutron beams in order to provide reliable monitoring at complex beam lines: low attenuation, linear response over a wide range of neutron fluxes, near to constant efficiency for neutron wavelengths in a range of 0.6-10 Å, calibration stability and the possibility to place the system in vacuum are all desirable characteristics. The scattering-based prototype, employing a natural vanadium foil and standard He3 proportional counters, was investigated at the V17 and V20 neutron beam lines of the Helmholtz-Zentrum in Berlin, Germany, in several different geometrical configurations of the He3 proportional counters around the foil. Response linearity is successfully demonstrated for foil thicknesses ranging from 0.04 mm to 3.15 mm. Attenuation lower than 1% for thermal neutrons is demonstrated for the 0.04 mm and 0.125 mm foils. The geometries used for the experiment were simulated allowing for absolute flux calibration and establishing the possible range of efficiencies for various designs of the prototype. The operational flux limits for the beam monitor prototype were established as a dependency of the background radiation and prototype geometry. The herein demonstrated prototype monitors can be employed for neutron intensities ranging from 103-1010 n/s.
  •  
5.
  • Mauritzson, N., et al. (författare)
  • Light-yield response of liquid scintillators using 2-6 MeV tagged neutrons
  • 2024
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 1062
  • Tidskriftsartikel (refereegranskat)abstract
    • Knowledge of the neutron light -yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2-6 MeV have been used to study the scintillation light -yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event -by -event waveform digitization. Energy calibration was performed using a GEANT4 model to locate the edge positions of the Compton distributions produced by gamma -ray sources. The simulated light yield for neutrons from a PuBe source was compared to measured recoil proton distributions, where neutron energy was selected by time -of -flight. This resulted in an energy -dependent Birks parameterization to characterize the non-linear response to the lower energy neutrons. The NE 213A and EJ 305 results agree very well with existing data and are reproduced nicely by the simulation. New results for EJ 331 and EJ 321P, where the simulation also reproduces the data well, are presented.
  •  
6.
  • Mauritzson, N., et al. (författare)
  • Light-yield response of liquid scintillators using 2–6 MeV tagged neutrons
  • 2024
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - 0168-9002. ; 1062
  • Tidskriftsartikel (refereegranskat)abstract
    • Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2–6 MeV have been used to study the scintillation light-yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event-by-event waveform digitization. Energy calibration was performed using a GEANT4 model to locate the edge positions of the Compton distributions produced by gamma-ray sources. The simulated light yield for neutrons from a PuBe source was compared to measured recoil proton distributions, where neutron energy was selected by time-of-flight. This resulted in an energy-dependent Birks parameterization to characterize the non-linear response to the lower energy neutrons. The NE 213A and EJ 305 results agree very well with existing data and are reproduced nicely by the simulation. New results for EJ 331 and EJ 321P, where the simulation also reproduces the data well, are presented.
  •  
7.
  • Mauritzson, N., et al. (författare)
  • Technique for the measurement of intrinsic pulse-shape discrimination for organic scintillators using tagged neutrons
  • 2022
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 1039
  • Tidskriftsartikel (refereegranskat)abstract
    • Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis. Gamma-ray sources and a Geant4-based simulation were used to calibrate the scintillation-light yield. The difference in pulse shape for the neutron and gamma-ray events was analyzed by integrating selected portions of the digitized waveform to produce a figure-of-merit for neutron/gamma-ray separation. This figure-of-merit has been mapped as a function of detector threshold and also of neutron energy determined from time-of-flight. It shows clearly that the well-established pulse-shape discrimination capabilities of NE 213A are superior to those of EJ 305. The extra information provided by the neutron-tagging technique has resulted in a far more detailed assessment of the pulse-shape-discrimination capabilities of these organic scintillators.
  •  
8.
  •  
9.
  • Messi, F., et al. (författare)
  • The neutron-tagging facility at Lund University
  • 2020
  • Ingår i: Modern Neutron Detection : Proceedings of a Technical Meeting - Proceedings of a Technical Meeting. - 1011-4289. - 9789201265203 - 9789201266200 ; :1935, s. 287-297
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Over the last decades, the field of thermal neutron detection has overwhelmingly employed He-3-based technologies. The He-3 crisis together with the forthcoming establishment of the European Spallation Source have necessitated the development of new technologies for neutron detection. Today, several promising He-3-free candidates are under detailed study and need to be validated. This validation process is in general long and expensive. The study of detector prototypes using neutron-emitting radioactive sources is a cost-effective solution, especially for preliminary investigations. That said, neutron-emitting sources have the general disadvantage of broad, structured, emitted-neutron energy ranges. Further, the emitted neutrons often compete with unwanted backgrounds of gamma-rays, alpha-particles, and fission-fragments. By blending experimental infrastructure such as shielding to provide particle beams with neutron-detection techniques such as tagging, disadvantages may be converted into advantages. In particular, a technique known as tagging involves exploiting the mixed-field generally associated with a neutron-emitting source to determine neutron time-of-flight and thus energy on an event-by-event basis. This allows for the definition of low-cost, precision neutron beams. The Source-Testing Facility, located at Lund University in Sweden and operated by the SONNIG Group of the Division of Nuclear Physics, was developed for just such low-cost studies. Precision tagged-neutron beams derived from radioactive sources are available around-the-clock for advanced detector diagnostic studies. Neutron measurements performed at the Source Testing Facility are thus cost-effective and have a very low barrier for entry. In this paper, we present an overview of the project.
  •  
10.
  • Rofors, E., et al. (författare)
  • Response of a Li-glass/multi-anode photomultiplier detector to alpha-particles from Am-241
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 929, s. 90-96
  • Tidskriftsartikel (refereegranskat)abstract
    • The response of a position-sensitive Li-glass scintillator detector to alpha-particles from a collimated Am-241 source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 x 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position and in general several pixels will register a signal (a hit) above a given threshold. The effect of this threshold on hit multiplicity is studied, with a view to optimize the single-hit efficiency of the detector.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy