1.
  • White, H, et al. (författare)
  • A certified plasmid reference material for the standardisation of BCR-ABL1 mRNA quantification by real time quantitative PCR.
  • 2015
  • Ingår i: Leukemia. - : Springer Science and Business Media LLC. - 1476-5551 .- 0887-6924. ; 29:2, s. 369-376
  • Tidskriftsartikel (refereegranskat)abstract
    • Serial quantification of BCR-ABL1 mRNA is an important therapeutic indicator in chronic myeloid leukemia, but there is substantial variation in results reported by different laboratories. To improve comparability, an internationally accepted plasmid certified reference material (CRM) was developed according to ISO Guide 34:2009. Fragments of BCR-ABL1 (e14a2 mRNA fusion), BCR and GUSB transcripts were amplified and cloned into pUC18 to yield plasmid pIRMM0099. Six different linearised plasmid solutions were produced with the following copy number concentrations, assigned by digital PCR, and expanded uncertainties: 1.08±0.13 × 10(6), 1.08±0.11 × 10(5), 1.03±0.10 × 10(4), 1.02±0.09 × 10(3), 1.04±0.10 × 10(2) and 10.0±1.5 copies/μL. The certification of the material for the number of specific DNA fragments per plasmid, copy number concentration of the plasmid solutions and the assessment of inter-unit heterogeneity and stability were performed according to ISO Guide 35:2006. Two suitability studies performed by 63 BCR-ABL1 testing laboratories demonstrated that this set of 6 plasmid CRMs can help to standardise the numbers of measured transcripts of e14a2 BCR-ABL1 and three control genes; ABL1, BCR and GUSB. The set of 6 plasmid CRMs is distributed worldwide by the Institute for Reference Materials and Measurements (Belgium) and its authorised distributors (http://irmm.jrc.ec.europa.eu; CRM code ERM-AD623a-f).Leukemia accepted article preview online, 18 July 2014; doi:10.1038/leu.2014.217.
  •  
2.
  • Boulo, S., et al. (författare)
  • First amyloid β1-42 certified reference material for re-calibrating commercial immunoassays
  • 2020
  • Ingår i: Alzheimer's and Dementia. - : Wiley. - 1552-5260 .- 1552-5279. ; 16:11, s. 1493-1503
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Reference materials based on human cerebrospinal fluid were certified for the mass concentration of amyloid beta (Aβ)1-42 (Aβ42). They are intended to be used to calibrate diagnostic assays for Aβ42. Methods: The three certified reference materials (CRMs), ERM-DA480/IFCC, ERM-DA481/IFCC and ERM-DA482/IFCC, were prepared at three concentration levels and characterized using isotope dilution mass spectrometry methods. Roche, EUROIMMUN, and Fujirebio used the three CRMs to re-calibrate their immunoassays. Results: The certified Aβ42 mass concentrations in ERM-DA480/IFCC, ERM-DA481/IFCC, and ERM-DA482/IFCC are 0.45, 0.72, and 1.22μg/L, respectively, with expanded uncertainties (k=2) of 0.07, 0.11, and 0.18μg/L, respectively. Before re-calibration, a good correlation (Pearson's r>0.97), yet large biases, were observed between results from different commercial assays. After re-calibration the between-assay bias was reduced to<5%. Discussion: The Aβ42 CRMs can ensure the equivalence of results between methods and across platforms for the measurement of Aβ42. © 2020 the Alzheimer's Association
  •  