SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(McKenna J.H.) "

Sökning: WFRF:(McKenna J.H.)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S., et al. (författare)
  • Electroweak measurements in electron positron collisions at W-boson-pair energies at LEP
  • 2013
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 532:4, s. 119-244
  • Forskningsöversikt (refereegranskat)abstract
    • Electroweak measurements performed with data taken at the electron positron collider LEP at CERN from 1995 to 2000 are reported. The combined data set considered in this report corresponds to a total luminosity of about 3 fb(-1) collected by the four LEP experiments ALEPH, DELPHI, 13 and OPAL, at centre-of-mass energies ranging from 130 GeV to 209 GeV. Combining the published results of the four LEP experiments, the measurements include total and differential cross-sections in photon-pair, fermion-pair and four-fermion production, the latter resulting from both double-resonant WW and ZZ production as well as singly resonant production. Total and differential cross-sections are measured precisely, providing a stringent test of the Standard Model at centre-of-mass energies never explored before in electron positron collisions. Final-state interaction effects in four-fermion production, such as those arising from colour reconnection and Bose Einstein correlations between the two W decay systems arising in WW production, are searched for and upper limits on the strength of possible effects are obtained. The data are used to determine fundamental properties of the W boson and the electroweak theory. Among others, the mass and width of the W boson, m(w) and Gamma(w), the branching fraction of W decays to hadrons, B(W -> had), and the trilinear gauge-boson self-couplings g(1)(Z), K-gamma and lambda(gamma), are determined to be: m(w) = 80.376 +/- 0.033 GeV Gamma(w) = 2.195 +/- 0.083 GeV B(W -> had) = 67.41 +/- 0.27% g(1)(Z) = 0.984(-0.020)(+0.018) K-gamma - 0.982 +/- 0.042 lambda(gamma) = 0.022 +/- 0.019. (C) 2013 Elsevier B.V. All rights reserved.
  •  
2.
  • Abazov, V. M., et al. (författare)
  • The upgraded DO detector
  • 2006
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 565:2, s. 463-537
  • Tidskriftsartikel (refereegranskat)abstract
    • The DO experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid -argon calorimeters and central muon detector, remaining from Run 1, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to DO.
  •  
3.
  •  
4.
  • Pirozhkov, A. S., et al. (författare)
  • Diagnostic of laser contrast using target reflectivity
  • 2009
  • Ingår i: Applied Physics Letters. - : AIP Publishing. - 0003-6951 .- 1077-3118. ; 94:24
  • Tidskriftsartikel (refereegranskat)abstract
    • Using three different laser systems, we demonstrate a convenient and simple plasma based diagnostic of the contrast of high-power short-pulse lasers. The technique is based on measuring the specular reflectivity from a solid target. The reflectivity remains high even at relativistic intensities above 10(19) W/cm(2) in the case of a high-contrast prepulse-free laser. On the contrary, the specular reflectivity drops with increasing intensities in the case of systems with insufficient contrast due to beam breakup and increased absorption caused by preplasma.
  •  
5.
  • Toprak, Muhammet S., 1973-, et al. (författare)
  • Control of size and permeability of nanocomposite microspheres
  • 2007
  • Ingår i: Chemistry of Materials. - : American Chemical Society (ACS). - 0897-4756 .- 1520-5002. ; 19:17, s. 4263-4269
  • Tidskriftsartikel (refereegranskat)abstract
    • This work reports on progress in controlling the size and porosity of spontaneously assembled composite polyelectrolyte microspheres for their potential use in targeted drug delivery applications. In this study, the composite polyelectrolyte microsphere is exemplified by PLK/TSC containing magnetic nanoparticles. The stability of these microspheres against environmental alterations such as pH, ionic strength, and dilution is a critical issue for practical considerations. The effects of ionic strength and dilution on the size of these hybrid spheres were investigated by the addition of salts with different cationic charges and deionized water. Increasing both ionic strength and dilution caused a decrease in the average size of microspheres from similar to 700 to similar to 200 nm. Ions of +2 charge were observed to screen interactions between the assembling components via a substitution effect. The composite polyelectrolyte microspheres could be mechanically stabilized by cross-linking with glutaraldehyde (GA). The microsphere permeabilities were analyzed using fluorescein-tagged dextran molecules of different MW with confocal laser scanning microscopy and fluorescence recovery after photobleaching. Microsphere permeabilities and critical pore sizes could be controllably decreased by altering the extent of cross-linking, which was monitored by UV-vis spectroscopy. Quantitative analysis revealed that cross-linking can be used to control the diffusion coefficient of dextran and can reduce it by 4 orders of magnitude.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy