SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Mesnard Thomas) "

Sökning: WFRF:(Mesnard Thomas)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Dias, N., et al. (författare)
  • Outcomes of Elective and Non-elective Fenestrated-branched Endovascular Aortic Repair for Treatment of Thoracoabdominal Aortic Aneurysms
  • 2023
  • Ingår i: Annals of Surgery. - : Lippincott Williams & Wilkins. - 0003-4932 .- 1528-1140. ; 278:4, s. 568-577, s. 568-577
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To describe outcomes after elective and non-elective fenestrated-branched endovascular aortic repair (FB-EVAR) for thoracoabdominal aortic aneurysms (TAAAs).Background: FB-EVAR has been increasingly utilized to treat TAAAs; however, outcomes after non-elective versus elective repair are not well described.Methods: Clinical data of consecutive patients undergoing FB-EVAR for TAAAs at 24 centers (2006-2021) were reviewed. Endpoints including early mortality and major adverse events (MAEs), all-cause mortality, and aortic-related mortality (ARM), were analyzed and compared in patients who had non-elective versus elective repair.Results: A total of 2603 patients (69% males; mean age 72 +/- 10 year old) underwent FB-EVAR for TAAAs. Elective repair was performed in 2187 patients (84%) and non-elective repair in 416 patients [16%; 268 (64%) symptomatic, 148 (36%) ruptured]. Non-elective FB-EVAR was associated with higher early mortality (17% vs 5%, P < 0.001) and rates of MAEs (34% vs 20%, P < 0.001). Median follow-up was 15 months ( interquartile range, 7-37 months). Survival and cumulative incidence of ARM at 3 years were both lower for non-elective versus elective patients (50 +/- 4% vs 70 +/- 1% and 21 +/- 3% vs 7 +/- 1%, P < 0.001). On multivariable analysis, non-elective repair was associated with increased risk of all-cause mortality ( hazard ratio, 1.92; 95% CI] 1.50-2.44; P < 0.001) and ARM (hazard ratio, 2.43; 95% CI, 1.63-3.62; P < 0.001).Conclusions: Non-elective FB-EVAR of symptomatic or ruptured TAAAs is feasible, but carries higher incidence of early MAEs and increased all-cause mortality and ARM than elective repair. Long-term follow-up is warranted to justify the treatment.
  •  
2.
  • Karelis, Angelos, et al. (författare)
  • Iliac Branch Devices in the Repair of Ruptured Aorto-iliac Aneurysms: A Multicenter Study
  • 2023
  • Ingår i: Journal of Endovascular Therapy. - : SAGE PUBLICATIONS INC. - 1526-6028 .- 1545-1550.
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To evaluate the outcomes of preserving the internal iliac artery (IIA) with iliac branched devices (IBDs) during acute endovascular repair of ruptured aortoiliac aneurysms. Material and Methods: This is a multicenter retrospective review of all consecutive patients undergoing acute endovascular repair of ruptured aortoiliac aneurysm with an IBD at 8 aortic centers between December 2012 and June 2020. A control group was used where the IIA was intentionally occluded from the same study period. The main outcome measures were 30-day mortality, major adverse events, technical success, and clinical success. Secondary outcomes were buttock claudication, primary patency, primary-assisted and secondary patency of the IBD, occurrence of endoleak types I/III, and reintervention. Values are presented as numbers and percentages or interquartile range in parenthesis. Results: Forty-eight patients were included in the study: 24 with IBD and 24 with IIA occlusion. There was no difference in demographics, cardiovascular risk factors, and aneurysm extent. Twenty (83%) of them were hemodynamically stable during the procedure as opposed to 14 (58%, p=.23) with the IIA occlusion. Technical success was achieved in all cases with a procedure time of 180 (133-254) minutes, 45 (23-65) of which were from IBD. There were 2 (8%) deaths during the first 30 days and 2 (8%) major complications unrelated to the IBD, whereas in the IIA occlusion, the figures were 10 (42%) and 7 (29%), respectively. No patient in the IBD group developed buttock claudication compared to 8 (57%, p<.0001) in the IIA occlusion group; 1 (4%) patient developed bowel ischemia on both groups, with 1 in the IIA occlusion group needing resection. The median follow-up duration was 17 months (interquartile range 2-39) for the IBD group, with a primary patency of 60 +/- 14% at 3 years that went up to 92 +/- 8% with reinterventions (8 reinterventions in 6 patients). When the first 90 days were disregarded, there were no differences in survival between the groups. Conclusion: IBD is a valid alternative for maintaining the pelvic circulation for endovascular aortic aneurysm repair of ruptured aortoiliac aneurysms. The technical success and midterm outcomes are very satisfactory but require patient selection particularly regarding hemodynamic stability. The reintervention rate is considerable, mandating continuous follow-up. Clinical Impact This multicenter study demonstrates that ruptured aortoiliac aneurysms do not necessarily require mandatory occlusion of hypogastric arteries. Iliac branch devices are shown to be a valid alternative in highly selected cases, with good midterm results, even if reinterventions are required in a significant proportion of patients.
  •  
3.
  • Tsilimparis, Nikolaos, et al. (författare)
  • Transatlantic multicenter study on the use of a modified preloaded delivery system for fenestrated endovascular aortic repair
  • 2023
  • Ingår i: Journal of Vascular Surgery. - 0741-5214. ; 78:4, s. 3-873
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Analyze the outcomes of endovascular complex abdominal and thoracoabdominal aortic aneurysm repair using the Cook fenestrated device with the modified preloaded delivery system (MPDS) with a biport handle and preloaded catheters. Methods: A multicenter retrospective single arm cohort study was performed, including all consecutive patients with complex abdominal aortic aneurysm repair and thoracoabdominal aortic aneurysms treated with the MPDS fenestrated device (Cook Medical). Patient clinical characteristics, anatomy, and indications for device use were collected. Outcomes, classified according to the Society for Vascular Surgery reporting standards, were collected at discharge, 30 days, 6 months, and annually thereafter. Results: Overall, 712 patients (median age, 73 years; interquartile range [IQR], 68-78 years; 83% male) from 16 centers in Europe and the United States treated electively were included: 35.4% (n = 252) presented with thoracoabdominal aortic aneurysms and 64.6% (n = 460) with complex abdominal aortic aneurysm repair. Overall, 2755 target vessels were included (mean, 3.9 per patient). Of these, 1628 were incorporated via ipsilateral preloads using the MPDS (1440 accessed from the biport handle and 188 from above). The mean size of the contralateral femoral sheath during target vessel catheterization was 15F ± 4, and in 41 patients (6.7%) the sheath size was ≤8F. Technical success was 96.1%. Median procedural time was 209 minutes (IQR, 161-270 minutes), contrast volume was 100 mL (IQR, 70-150mL), fluoroscopy time was 63.9 minutes (IQR, 49.7-80.4 minutes) and median cumulative air kerma radiation dose was 2630 mGy (IQR, 838-5251 mGy). Thirty-day mortality was 4.8% (n = 34). Access complications occurred in 6.8% (n = 48) and 30-day reintervention in 7% (n = 50; 18 branch related). Follow-up of >30 days was available for 628 patients (88%), with a median follow-up of 19 months (IQR, 8-39 months). Branch-related endoleaks (type Ic/IIIc) were observed in 15 patients (2.6%) and aneurysm growth of >5 mm was observed in 54 (9.5%). Freedom from reintervention at 12 and 24 months was 87.1% (standard error [SE],1.5%) and 79.2% (SE, 2.0%), respectively. Overall target vessel patency at 12 and 24 months was 98.6% (SE, 0.3%) and 96.8% (SE, 0.4%), respectively, and was 97.9% (SE, 0.4%) and 95.3% (SE, 0.8%) for arteries stented from below using the MPDS, respectively. Conclusions: The MPDS is safe and effective. Overall benefits include a decrease in contralateral sheath size in the treatment of complex anatomies with favorable results.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy