SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Messina Antonio) "

Sökning: WFRF:(Messina Antonio)

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • 2019
  • Tidskriftsartikel (refereegranskat)
  •  
2.
  • van Leeuwen, F., et al. (författare)
  • Gaia Data Release 1 : Open cluster astrometry: Performance, limitations, and future prospects
  • 2017
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 601
  • Tidskriftsartikel (refereegranskat)abstract
    • Context. The first Gaia Data Release contains the Tycho-Gaia Astrometric Solution (TGAS). This is a subset of about 2 million stars for which, besides the position and photometry, the proper motion and parallax are calculated using Hipparcos and Tycho-2 positions in 1991.25 as prior information. Aims. We investigate the scientific potential and limitations of the TGAS component by means of the astrometric data for open clusters. Methods. Mean cluster parallax and proper motion values are derived taking into account the error correlations within the astrometric solutions for individual stars, an estimate of the internal velocity dispersion in the cluster, and, where relevant, the effects of the depth of the cluster along the line of sight. Internal consistency of the TGAS data is assessed. Results. Values given for standard uncertainties are still inaccurate and may lead to unrealistic unit-weight standard deviations of least squares solutions for cluster parameters. Reconstructed mean cluster parallax and proper motion values are generally in very good agreement with earlier Hipparcos-based determination, although the Gaia mean parallax for the Pleiades is a significant exception. We have no current explanation for that discrepancy. Most clusters are observed to extend to nearly 15 pc from the cluster centre, and it will be up to future Gaia releases to establish whether those potential cluster-member stars are still dynamically bound to the clusters. Conclusions. The Gaia DR1 provides the means to examine open clusters far beyond their more easily visible cores, and can provide membership assessments based on proper motions and parallaxes. A combined HR diagram shows the same features as observed before using the Hipparcos data, with clearly increased luminosities for older A and F dwarfs.
  •  
3.
  •  
4.
  • Cozza, Vittoria, et al. (författare)
  • Spatio-Temporal Keyword Queries in Social Networks
  • 2013
  • Ingår i: 17th East-European Conference on Advances in Databases and Information Systems (ADBIS). - Berlin, Heidelberg : Springer Berlin Heidelberg. ; , s. 70-83
  • Konferensbidrag (refereegranskat)abstract
    • Due to the large amount of social network data produced at an ever growing speed and their complex nature, recent works have addressed the problem of efficiently querying such data according to social, temporal or spatial dimensions. In this work we propose a data model that keeps into account all these dimensions and we compare different approaches for efficient query execution on a large real dataset using standard relational technologies.
  •  
5.
  • De Backer, Daniel, et al. (författare)
  • How can assessing hemodynamics help to assess volume status?
  • 2022
  • Ingår i: Intensive Care Medicine. - : SPRINGER. - 0342-4642 .- 1432-1238. ; 48, s. 11482-1494
  • Forskningsöversikt (refereegranskat)abstract
    • In critically ill patients, fluid infusion is aimed at increasing cardiac output and tissue perfusion. However, it may contribute to fluid overload which may be harmful. Thus, volume status, risks and potential efficacy of fluid administration and/or removal should be carefully evaluated, and monitoring techniques help for this purpose. Central venous pressure is a marker of right ventricular preload. Very low values indicate hypovolemia, while extremely high values suggest fluid harmfulness. The pulmonary artery catheter enables a comprehensive assessment of the hemodynamic profile and is particularly useful for indicating the risk of pulmonary oedema through the pulmonary artery occlusion pressure. Besides cardiac output and preload, transpulmonary thermodilution measures extravascular lung water, which reflects the extent of lung flooding and assesses the risk of fluid infusion. Echocardiography estimates the volume status through intravascular volumes and pressures. Finally, lung ultrasound estimates lung edema. Guided by these variables, the decision to infuse fluid should first consider specific triggers, such as signs of tissue hypoperfusion. Second, benefits and risks of fluid infusion should be weighted. Thereafter, fluid responsiveness should be assessed. Monitoring techniques help for this purpose, especially by providing real time and precise measurements of cardiac output. When decided, fluid resuscitation should be performed through fluid challenges, the effects of which should be assessed through critical endpoints including cardiac output. This comprehensive evaluation of the risk, benefits and efficacy of fluid infusion helps to individualize fluid management, which should be preferred over a fixed restrictive or liberal strategy.
  •  
6.
  • Messina, Antonio, et al. (författare)
  • Consistency of data reporting in fluid responsiveness studies in the critically ill setting: the CODEFIRE consensus from the Cardiovascular Dynamic section of the European Society of Intensive Care Medicine
  • 2024
  • Ingår i: Intensive Care Medicine. - : SPRINGER. - 0342-4642 .- 1432-1238.
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTo provide consensus recommendations regarding hemodynamic data reporting in studies investigating fluid responsiveness and fluid challenge (FC) use in the intensive care unit (ICU).MethodsThe Executive Committee of the European Society of Intensive Care Medicine (ESICM) commissioned and supervised the project. A panel of 18 international experts and a methodologist identified main domains and items from a systematic literature, plus 2 ancillary domains. A three-step Delphi process based on an iterative approach was used to obtain the final consensus. In the Delphi 1 and 2, the items were selected with strong (>= 80% of votes) or week agreement (70-80% of votes), while the Delphi 3 generated recommended (>= 90% of votes) or suggested (80-90% of votes) items (RI and SI, respectively).ResultsWe identified 5 main domains initially including 117 items and the consensus finally resulted in 52 recommendations or suggestions: 18 RIs and 2 SIs statements were obtained for the domain "ICU admission", 11 RIs and 1 SI for the domain "mechanical ventilation", 5 RIs for the domain "reason for giving a FC", 8 RIs for the domain pre- and post-FC "hemodynamic data", and 7 RIs for the domain "pre-FC infused drugs". We had no consensus on the use of echocardiography, strong agreement regarding the volume (4 ml/kg) and the reference variable (cardiac output), while weak on administration rate (within 10 min) of FC in this setting.ConclusionThis consensus found 5 main domains and provided 52 recommendations for data reporting in studies investigating fluid responsiveness in ICU patients.
  •  
7.
  • Messina, Antonio, et al. (författare)
  • Pathophysiology of fluid administration in critically ill patients
  • 2022
  • Ingår i: Intensive Care Medicine Experimental. - : Springer. - 2197-425X. ; 10:1
  • Forskningsöversikt (refereegranskat)abstract
    • Fluid administration is a cornerstone of treatment of critically ill patients. The aim of this review is to reappraise the pathophysiology of fluid therapy, considering the mechanisms related to the interplay of flow and pressure variables, the systemic response to the shock syndrome, the effects of different types of fluids administered and the concept of preload dependency responsiveness. In this context, the relationship between preload, stroke volume (SV) and fluid administration is that the volume infused has to be large enough to increase the driving pressure for venous return, and that the resulting increase in end-diastolic volume produces an increase in SV only if both ventricles are operating on the steep part of the curve. As a consequence, fluids should be given as drugs and, accordingly, the dose and the rate of administration impact on the final outcome. Titrating fluid therapy in terms of overall volume infused but also considering the type of fluid used is a key component of fluid resuscitation. A single, reliable, and feasible physiological or biochemical parameter to define the balance between the changes in SV and oxygen delivery (i.e., coupling "macro" and "micro" circulation) is still not available, making the diagnosis of acute circulatory dysfunction primarily clinical.
  •  
8.
  • Messina, Antonio, et al. (författare)
  • Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
  • 2023
  • Ingår i: Critical Care. - : BMC. - 1364-8535 .- 1466-609X. ; 27:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundPulse pressure and stroke volume variation (PPV and SVV) have been widely used in surgical patients as predictors of fluid challenge (FC) response. Several factors may affect the reliability of these indices in predicting fluid responsiveness, such as the position of the patient, the use of laparoscopy and the opening of the abdomen or the chest, combined FC characteristics, the tidal volume (Vt) and the type of anesthesia.MethodsSystematic review and metanalysis of PPV and SVV use in surgical adult patients. The QUADAS-2 scale was used to assess the risk of bias of included studies. We adopted a metanalysis pooling of aggregate data from 5 subgroups of studies with random effects models using the common-effect inverse variance model. The area under the curve (AUC) of pooled receiving operating characteristics (ROC) curves was reported. A metaregression was performed using FC type, volume, and rate as independent variables.ResultsWe selected 59 studies enrolling 2,947 patients, with a median of fluid responders of 55% (46-63). The pooled AUC for the PPV was 0.77 (0.73-0.80), with a mean threshold of 10.8 (10.6-11.0). The pooled AUC for the SVV was 0.76 (0.72-0.80), with a mean threshold of 12.1 (11.6-12.7); 19 studies (32.2%) reported the grey zone of PPV or SVV, with a median of 56% (40-62) and 57% (46-83) of patients included, respectively. In the different subgroups, the AUC and the best thresholds ranged from 0.69 and 0.81 and from 6.9 to 11.5% for the PPV, and from 0.73 to 0.79 and 9.9 to 10.8% for the SVV. A high Vt and the choice of colloids positively impacted on PPV performance, especially among patients with closed chest and abdomen, or in prone position.ConclusionThe overall performance of PPV and SVV in operating room in predicting fluid responsiveness is moderate, ranging close to an AUC of 0.80 only some subgroups of surgical patients. The grey zone of these dynamic indices is wide and should be carefully considered during the assessment of fluid responsiveness. A high Vt and the choice of colloids for the FC are factors potentially influencing PPV reliability.Trial Registration: PROSPERO (CRD42022379120), December 2022. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=379120ConclusionThe overall performance of PPV and SVV in operating room in predicting fluid responsiveness is moderate, ranging close to an AUC of 0.80 only some subgroups of surgical patients. The grey zone of these dynamic indices is wide and should be carefully considered during the assessment of fluid responsiveness. A high Vt and the choice of colloids for the FC are factors potentially influencing PPV reliability.Trial Registration: PROSPERO (CRD42022379120), December 2022. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=379120
  •  
9.
  •  
10.
  • Robba, Chiara, et al. (författare)
  • Basic ultrasound head-to-toe skills for intensivists in the general and neuro intensive care unit population : consensus and expert recommendations of the European Society of Intensive Care Medicine
  • 2021
  • Ingår i: Intensive Care Medicine. - : Springer. - 0342-4642 .- 1432-1238. ; 47:12, s. 1347-1367
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose To provide consensus, and a list of experts recommendations regarding the basic skills for head-to-toe ultrasonography in the intensive care setting. Methods The Executive Committee of the European Society of Intensive Care (ESICM) commissioned the project and supervised the methodology and structure of the consensus. We selected an international panel of 19 expert clinicians-researchers in intensive care unit (ICU) with expertise in critical care ultrasonography (US), plus a non-voting methodologist. The panel was divided into five subgroups (brain, lung, heart, abdomen and vascular ultrasound) which identified the domains and generated a list of questions to be addressed by the panel. A Delphi process based on an iterative approach was used to obtain the final consensus statements. Statements were classified as a strong recommendation (84% of agreement), weak recommendation (74% of agreement), and no recommendation (less than 74%), in favor or against. Results This consensus produced a total of 74 statements (7 for brain, 20 for lung, 20 for heart, 20 for abdomen, 7 for vascular Ultrasound). We obtained strong agreement in favor for 49 statements (66.2%), 8 weak in favor (10.8%), 3 weak against (4.1%), and no consensus in 14 cases (19.9%). In most cases when consensus was not obtained, it was felt that the skills were considered as too advanced. A research agenda and discussion on training programs were implemented from the results of the consensus. Conclusions This consensus provides guidance for the basic use of critical care US and paves the way for the development of training and research projects.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy