SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Mijakowski P) "

Sökning: WFRF:(Mijakowski P)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abe, K., et al. (författare)
  • J-PARC Neutrino Beamline Upgrade Technical Design Report
  • 2019
  • Rapport (refereegranskat)abstract
    • In this document, technical details of the upgrade plan of the J-PARC neutrino beamline for the extension of the T2K experiment are described. T2K has proposed to accumulate data corresponding to 2×1022 protons-on-target in the next decade, aiming at an initial observation of CP violation with 3σ or higher significance in the case of maximal CP violation. Methods to increase the neutrino beam intensity, which are necessary to achieve the proposed data increase, are described.
  •  
2.
  • Abe, K., et al. (författare)
  • Neutron tagging following atmospheric neutrino events in a water Cherenkov detector
  • 2022
  • Ingår i: Journal of Instrumentation. - : Institute of Physics (IOP). - 1748-0221 .- 1748-0221. ; 17:10
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the development of neutron-tagging techniques in Super-Kamiokande IV using a neural network analysis. The detection efficiency of neutron capture on hydrogen is estimated to be 26%, with a mis-tag rate of 0.016 per neutrino event. The uncertainty of the tagging efficiency is estimated to be 9.0%. Measurement of the tagging efficiency with data from an Americium-Beryllium calibration agrees with this value within 10%. The tagging procedure was performed on 3,244.4 days of SK-IV atmospheric neutrino data, identifying 18,091 neutrons in 26,473 neutrino events. The fitted neutron capture lifetime was measured as 218 +/- 9 mu s.
  •  
3.
  • Ankowski, A., et al. (författare)
  • Energy reconstruction of electromagnetic showers from Ν0 decays with the ICARUS T600 liquid argon TPC
  • 2010
  • Ingår i: Acta Physica Polonica, Series B.. - 1509-5770 .- 0587-4254. ; 41:1, s. 103-125
  • Tidskriftsartikel (refereegranskat)abstract
    • We discuss the ICARUS T600 detector capabilities in electromagnetic shower reconstruction through the analysis of a sample of 212 events, coming from the 2001 Pavia surface test run, of hadronic interactions leading to the production of π 0 mesons. Methods of shower energy and shower direction measurements were developed and the invariant mass of the photon pairs was reconstructed. The (γγ) invariant mass was found to be consistent with the value of the π 0 mass. The resolution of the reconstructed π 0 mass was found to be equal to 27.3%. An improved analysis, carried out in order to clean the full event sample from the events measured in the crowded environment, mostly due to the trigger conditions, gave a π 0 mass resolution of 16.1%, significantly better than the one evaluated for the full event sample. The trigger requirement of the coincidence of at least four photo-multiplier signals favored the selection of events with a strong pile up of cosmic ray tracks and interactions. Hence a number of candidate π 0 events were heavily contaminated by other tracks and had to be rejected. Monte Carlo simulations of events with π 0 production in hadronic and neutrino interactions confirmed the validity of the shower energy and shower direction reconstruction methods applied to the real data.
  •  
4.
  • Ankowski, A, et al. (författare)
  • Energy reconstruction of electromagnetic showers from π0 decays with the ICARUS T600 liquid argon TPC
  • 2010
  • Ingår i: Acta Physica Polonica B. - : Jagellonian University. - 0587-4254 .- 1509-5770. ; 41:1, s. 103-125
  • Tidskriftsartikel (refereegranskat)abstract
    • We discuss the ICARUS T600 detector capabilities in electromagnetic shower reconstruction through the analysis of a sample of 212 events, coming from the 2001 Pavia surface test run, of hadronic interactions leading to the production of π0 mesons. Methods of shower energy and shower direction measurements were developed and the invariant mass of the photon pairs was reconstructed. The (γ,γ) invariant mass was found to be consistent with the value of the π0 mass. The resolution of the reconstructed π0 mass was found to be equal to 27.3%. An improved analysis, carried out in order to clean the full event sample from the events measured in the crowded environment, mostly due to the trigger conditions, gave a π0 mass resolution of 16.1%, significantly better than the one evaluated for the full event sample. The trigger requirement of the coincidence of at least four photo-multiplier signals favored the selection of events with a strong pile up of cosmic ray tracks and interactions. Hence a number of candidate π0 events were heavily contaminated by other tracks and had to be rejected. Monte Carlo simulations of events with π0 production in hadronic and neutrino interactions confirmed the validity of the shower energy and shower direction reconstruction methods applied to the real data.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy