SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Mohr Michel) "

Sökning: WFRF:(Mohr Michel)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Schael, S., et al. (författare)
  • Electroweak measurements in electron positron collisions at W-boson-pair energies at LEP
  • 2013
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 532:4, s. 119-244
  • Forskningsöversikt (refereegranskat)abstract
    • Electroweak measurements performed with data taken at the electron positron collider LEP at CERN from 1995 to 2000 are reported. The combined data set considered in this report corresponds to a total luminosity of about 3 fb(-1) collected by the four LEP experiments ALEPH, DELPHI, 13 and OPAL, at centre-of-mass energies ranging from 130 GeV to 209 GeV. Combining the published results of the four LEP experiments, the measurements include total and differential cross-sections in photon-pair, fermion-pair and four-fermion production, the latter resulting from both double-resonant WW and ZZ production as well as singly resonant production. Total and differential cross-sections are measured precisely, providing a stringent test of the Standard Model at centre-of-mass energies never explored before in electron positron collisions. Final-state interaction effects in four-fermion production, such as those arising from colour reconnection and Bose Einstein correlations between the two W decay systems arising in WW production, are searched for and upper limits on the strength of possible effects are obtained. The data are used to determine fundamental properties of the W boson and the electroweak theory. Among others, the mass and width of the W boson, m(w) and Gamma(w), the branching fraction of W decays to hadrons, B(W -> had), and the trilinear gauge-boson self-couplings g(1)(Z), K-gamma and lambda(gamma), are determined to be: m(w) = 80.376 +/- 0.033 GeV Gamma(w) = 2.195 +/- 0.083 GeV B(W -> had) = 67.41 +/- 0.27% g(1)(Z) = 0.984(-0.020)(+0.018) K-gamma - 0.982 +/- 0.042 lambda(gamma) = 0.022 +/- 0.019. (C) 2013 Elsevier B.V. All rights reserved.
  •  
3.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
4.
  • Toussaint, Anne, et al. (författare)
  • Defects in amphiphysin 2 (BIN1) and triads in several forms of centronuclear myopathies.
  • 2011
  • Ingår i: Acta neuropathologica. - : Springer Science and Business Media LLC. - 1432-0533 .- 0001-6322. ; 121:2, s. 253-266
  • Tidskriftsartikel (refereegranskat)abstract
    • Myotubular myopathy and centronuclear myopathies (CNM) are congenital myopathies characterized by generalized muscle weakness and mislocalization of muscle fiber nuclei. Genetically distinct forms exist, and mutations in BIN1 were recently identified in autosomal recessive cases (ARCNM). Amphiphysins have been implicated in membrane remodeling in brain and skeletal muscle. Our objective was to decipher the pathogenetic mechanisms underlying different forms of CNM, with a focus on ARCNM cases. In this study, we compare the histopathological features from patients with X-linked, autosomal recessive, and dominant forms, respectively, mutated in myotubularin (MTM1), amphiphysin 2 (BIN1), and dynamin 2 (DNM2). We further characterize the ultrastructural defects in ARCNM muscles. We demonstrate that the two BIN1 isoforms expressed in skeletal muscle possess the phosphoinositide-binding domain and are specifically targeted to the triads close to the DHPR-RYR1 complex. Cardiac isoforms do not contain this domain, suggesting that splicing of BIN1 regulates its specific function in skeletal muscle. Immunofluorescence analyses of muscles from patients with BIN1 mutations reveal aberrations of BIN1 localization and triad organization. These defects are also observed in X-linked and autosomal dominant forms of CNM and in Mtm1 knockout mice. In addition to previously reported implications of BIN1 in cancer as a tumor suppressor, these findings sustain an important role for BIN1 skeletal muscle isoforms in membrane remodeling and organization of the excitation-contraction machinery. We propose that aberrant BIN1 localization and defects in triad structure are part of a common pathogenetic mechanism shared between the three forms of centronuclear myopathies.
  •  
5.
  • Wouters, Michel W., et al. (författare)
  • ECCO essential requirements for quality cancer care: Melanoma
  • 2018
  • Ingår i: Critical reviews in oncology/hematology. - : Elsevier BV. - 1040-8428. ; 122, s. 164-178
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: ECCO essential requirements for quality cancer care (ERQCC) are explanations and descriptions of challenges, organisation and actions that are necessary to give high-quality care to patients who have a specific type of cancer. They are written by European experts representing all disciplines involved in cancer care. ERQCC papers give oncology teams, patients, policymakers and managers an overview of the elements needed in any healthcare system to provide high quality of care throughout the patient journey. References are made to clinical guidelines and other resources where appropriate, and the focus is on care in Europe. Melanoma: essential requirements for quality care: • Melanoma, the most-deadly skin cancer, is rising in incidence among fair-skinned people in Europe. Increasing complexity of care for advanced disease in clinical areas such as staging and new therapies requires attention to a number of challenges and inequalities in a diverse patient group.• Care for advanced melanoma must only be carried out in, or in collaboration with, specialist melanoma centres which have both a core multidisciplinary team and an extended team of allied professionals, and which are subject to quality and audit procedures. Access to such units is far from universal in all European countries.• It is essential that, to meet European aspirations for high-quality comprehensive cancer control, healthcare organisations implement the requirements in this paper, paying particular attention to multidisciplinarity and patient-centred pathways from diagnosis to treatment and follow-up, to improve survival and quality of life for patients.Conclusion: Taken together, the information presented in this paper provides a comprehensive description of the essential requirements for establishing a high-quality service for melanoma. The ERQCC expert group is aware that it is not possible to propose a ‘one size fits all’ system for all countries, but urges that access to multidisciplinary teams and specialised treatments is guaranteed to all patients with melanoma.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy