SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Morelli Luca) "

Sökning: WFRF:(Morelli Luca)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Amati, L., et al. (författare)
  • The THESEUS space mission concept : science case, design and expected performances
  • 2018
  • Ingår i: Advances in Space Research. - : ELSEVIER SCI LTD. - 0273-1177 .- 1879-1948. ; 62:1, s. 191-244
  • Tidskriftsartikel (refereegranskat)abstract
    • THESEUS is a space mission concept aimed at exploiting Gamma-Ray Bursts for investigating the early Universe and at providing a substantial advancement of multi-messenger and time-domain astrophysics. These goals will be achieved through a unique combination of instruments allowing GRB and X-ray transient detection over a broad field of view (more than 1 sr) with 0.5-1 arcmin localization, an energy band extending from several MeV down to 0.3 keV and high sensitivity to transient sources in the soft X-ray domain, as well as on-board prompt (few minutes) follow-up with a 0.7 m class IR telescope with both imaging and spectroscopic capabilities. THESEUS will be perfectly suited for addressing the main open issues in cosmology such as, e.g., star formation rate and metallicity evolution of the inter-stellar and intra-galactic medium up to redshift similar to 10, signatures of Pop III stars, sources and physics of re-ionization, and the faint end of the galaxy luminosity function. In addition, it will provide unprecedented capability to monitor the X-ray variable sky, thus detecting, localizing, and identifying the electromagnetic counterparts to sources of gravitational radiation, which may be routinely detected in the late '20s/early '30s by next generation facilities like aLIGO/ aVirgo, eLISA, KAGRA, and Einstein Telescope. THESEUS will also provide powerful synergies with the next generation of multi-wavelength observatories (e.g., LSST, ELT, SKA, CTA, ATHENA).
  •  
3.
  • de Graaf, Nine, et al. (författare)
  • Minimally invasive versus open pancreatoduodenectomy for pancreatic and peri-ampullary neoplasm (DIPLOMA-2) : study protocol for an international multicenter patient-blinded randomized controlled trial
  • 2023
  • Ingår i: Trials. - : BioMed Central Ltd. - 1745-6215. ; 24:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Minimally invasive pancreatoduodenectomy (MIPD) aims to reduce the negative impact of surgery as compared to open pancreatoduodenectomy (OPD) and is increasingly becoming part of clinical practice for selected patients worldwide. However, the safety of MIPD remains a topic of debate and the potential shorter time to functional recovery needs to be confirmed. To guide safe implementation of MIPD, large-scale international randomized trials comparing MIPD and OPD in experienced high-volume centers are needed. We hypothesize that MIPD is non-inferior in terms of overall complications, but superior regarding time to functional recovery, as compared to OPD. Methods/design: The DIPLOMA-2 trial is an international randomized controlled, patient-blinded, non-inferiority trial performed in 14 high-volume pancreatic centers in Europe with a minimum annual volume of 30 MIPD and 30 OPD. A total of 288 patients with an indication for elective pancreatoduodenectomy for pre-malignant and malignant disease, eligible for both open and minimally invasive approach, are randomly allocated for MIPD or OPD in a 2:1 ratio. Centers perform either laparoscopic or robot-assisted MIPD based on their surgical expertise. The primary outcome is the Comprehensive Complication Index (CCI®), measuring all complications graded according to the Clavien-Dindo classification up to 90 days after surgery. The sample size is calculated with the following assumptions: 2.5% one-sided significance level (α), 80% power (1-β), expected difference of the mean CCI® score of 0 points between MIPD and OPD, and a non-inferiority margin of 7.5 points. The main secondary outcome is time to functional recovery, which will be analyzed for superiority. Other secondary outcomes include post-operative 90-day Fitbit™ measured activity, operative outcomes (e.g., blood loss, operative time, conversion to open surgery, surgeon-reported outcomes), oncological findings in case of malignancy (e.g., R0-resection rate, time to adjuvant treatment, survival), postoperative outcomes (e.g., clinically relevant complications), healthcare resource utilization (length of stay, readmissions, intensive care stay), quality of life, and costs. Postoperative follow-up is up to 36 months. Discussion: The DIPLOMA-2 trial aims to establish the safety of MIPD as the new standard of care for this selected patient population undergoing pancreatoduodenectomy in high-volume centers, ultimately aiming for superior patient recovery. Trial registration: ISRCTN27483786. Registered on August 2, 2023. © 2023, BioMed Central Ltd., part of Springer Nature.
  •  
4.
  • Gentiluomo, Manuel, et al. (författare)
  • Mitochondrial DNA Copy-Number Variation and Pancreatic Cancer Risk in the Prospective EPIC Cohort
  • 2020
  • Ingår i: Cancer Epidemiology, Biomarkers and Prevention. - Philadelphia : American Association for Cancer Research. - 1055-9965 .- 1538-7755. ; 29:3, s. 681-686
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Mitochondrial DNA (mtDNA) copy number in peripheral blood has been found to be sociated with risk of developing several cancers. However, data on pancreatic ductal adenocarcinoma DAC) are very limited.Methods: To further our knowledge on this topic, we measured relative mtDNA copy number by a antitative real-time PCR assay in peripheral leukocyte samples of 476PDACcases and 357 controls sted within the European Prospective Investigation into Cancer and Nutrition (EPIC) cohort.Results: We observed lower mtDNA copy number with advancing age (P = 6.54 x 10(-5)) and with a high dy mass index (BMI) level (P = 0.004) and no association with sex, smoking behavior, and alcohol nsumption. We found an association between increased mtDNA copy number and decreased risk of veloping PDAC with an odds ratios (OR) of 0.35 [95% confidence interval (CI), 0.160.79; P = 0.01] when mparing the fifth quintile with the first using an unconditional logistic regression and an OR of 0.19 5% CI, 0.07-0.52; P = 0.001) with a conditional analysis. Analyses stratified by BMI showed an sociation between high mtDNA copy number and decreased risk in the stratum of normal weight, nsistent with the main analyses.Conclusions: Our results suggest a protective effect of a higher number of mitochondria, measured in ripheral blood leukocytes, on PDAC risk.Impact: Our findings highlight the importance of understanding the mitochondrial biology in pancreatic ncer.
  •  
5.
  • Lange, Dale J., et al. (författare)
  • Pyrimethamine Significantly Lowers Cerebrospinal Fluid Cu/Zn Superoxide Dismutase in Amyotrophic Lateral Sclerosis Patients with SOD1 Mutations
  • 2017
  • Ingår i: Annals of Neurology. - : John Wiley & Sons. - 0364-5134 .- 1531-8249. ; 81:6, s. 837-848
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Cu/Zn superoxide dismutase (SOD1) reduction prolongs survival in SOD1-transgenic animal models. Pyrimethamine produces dose-dependent SOD1 reduction in cell culture systems. A previous phase 1 trial showed pyrimethamine lowers SOD1 levels in leukocytes in patients with SOD1 mutations. This study investigated whether pyrimethamine lowered SOD1 levels in the cerebrospinal fluid (CSF) in patients carrying SOD1 mutations linked to familial amyotrophic lateral sclerosis (fALS/SOD1). Methods: A multicenter (5 sites), open-label, 9-month-duration, dose-ranging study was undertaken to determine the safety and efficacy of pyrimethamine to lower SOD1 levels in the CSF in fALS/SOD1. All participants underwent 3 lumbar punctures, blood draw, clinical assessment of strength, motor function, quality of life, and adverse effect assessments. SOD1 levels were measured in erythrocytes and CSF. Pyrimethamine was measured in plasma and CSF. Appel ALS score, ALS Functional Rating Scale-Revised, and McGill Quality of Life Single-Item Scale were measured at screening, visit 6, and visit 9. Results: We enrolled 32 patients; 24 completed 6 visits (18 weeks), and 21 completed all study visits. A linear mixed effects model showed a significant reduction in CSF SOD1 at visit 6 (p<0.001) with a mean reduction of 13.5% (95% confidence interval [CI] 58.4-18.5) and at visit 9 (p<0.001) with a mean reduction of 10.5% (95% CI55.2-15.8). Interpretation: Pyrimethamine is safe and well tolerated in ALS. Pyrimethamine is capable of producing a significant reduction in total CSF SOD1 protein content in patients with ALS caused by different SOD1 mutations. Further long-term studies are warranted to assess clinical efficacy.
  •  
6.
  • Sanna, Daria, et al. (författare)
  • Mendelian breeding units versus standard sampling strategies: Mitochondrial DNA variation in southwest Sardinia
  • 2011
  • Ingår i: Genetics and Molecular Biology. - 1678-4685. ; 34:2, s. 187-194
  • Tidskriftsartikel (refereegranskat)abstract
    • We report a sampling strategy based on Mendelian Breeding Units (MBUs), representing an interbreeding group of individuals sharing a common gene pool. The identification of MBUs is crucial for case-control experimental design in association studies. The aim of this work was to evaluate the possible existence of bias in terms of genetic variability and haplogroup frequencies in the MBU sample, due to severe sample selection. In order to reach this goal, the MBU sampling strategy was compared to a standard selection of individuals according to their surname and place of birth. We analysed mitochondrial DNA variation (first hypervariable segment and coding region) in unrelated healthy subjects from two different areas of Sardinia: the area around the town of Cabras and the western Campidano area. No statistically significant differences were observed when the two sampling methods were compared, indicating that the stringent sample selection needed to establish a MBU does not alter original genetic variability and haplogroup distribution. Therefore, the MBU sampling strategy can be considered a useful tool in association studies of complex traits.
  •  
7.
  • Testa, Veronica, et al. (författare)
  • Micromechanical behaviour and wear resistance of hybrid plasma-sprayed TiC reinforced Tribaloy-400
  • 2021
  • Ingår i: Surface & Coatings Technology. - : Elsevier. - 0257-8972 .- 1879-3347. ; 425
  • Tidskriftsartikel (refereegranskat)abstract
    • Cobalt-based alloys such as Tribaloy-400 are known for their sliding wear resistance at room as well as elevated temperature. However, further enhancement in terms of hardness and wear resistance could be achieved by creating metal matrix composites reinforced by ceramic particles. For this purpose, Tribaloy-400 based coatings were deposited with the addition of different amounts of TiC reinforcement (≈25 vol%, ≈40 vol%, ≈60 vol%) through a “hybrid” plasma spray process, using a dry Tribaloy-400 powder with 10–45 μm particle size and a water-based TiC suspension (d50 = 2.2 μm). Pure Tribaloy and pure TiC coatings were employed for comparison. During spraying, TiC was partly oxidized but could nonetheless be embedded between the bigger Tribaloy-400 lamellae. Specifically, the coating containing ≈ 25 vol% TiC shows a homogeneous microstructure, whilst greater amounts of hard phase lead to some agglomeration. Accordingly, the coating with 25 vol% TiC exhibits a good combination of hardness and toughness (the latter being assessed by scratch testing) and low sliding wear rates of ≈10−5–10−6 mm3/(N·m) from room temperature up to 700 °C in ball-on-disc tests against an Al2O3 counterbody. At room temperature, the tribological behaviour of the coatings is controlled by abrasive grooving and spallation due to surface fatigue. With increasing temperature, tribochemical phenomena take on an ever-increasing role and, at 700 °C, a uniform, oxide-based tribofilm is developed, so that the wear rates are often lower than are recorded at 400 °C.
  •  
8.
  • Torkashvand, Kaveh, 1990-, et al. (författare)
  • Tribological behavior of HVAF-sprayed WC-based coatings with alternative binders
  • 2022
  • Ingår i: Surface & Coatings Technology. - : Elsevier. - 0257-8972 .- 1879-3347. ; 436
  • Tidskriftsartikel (refereegranskat)abstract
    • The tribological performance of High Velocity Air-Fuel (HVAF) sprayed WC-based cermet coatings with binders containing no or very limited amount of cobalt was evaluated under dry sliding, erosion, and abrasion wear conditions. The wear and corrosion behaviors of WC-NiMoCrFeCo, WC-FeNiCrMoCu and WC-FeCrAl HVAF sprayed coatings were investigated and compared to standard WC-CoCr coatings as benchmark. Microstructure characterization along with XRD analysis was conducted on all powders as well as the corresponding coatings. Comprehensive post wear analysis was conducted on all coatings subjected to ball-on-disk, gas jet erosion and dry sand-rubber wheel abrasion tests. Moreover, all coatings were exposed to 3.5% (wt./vol.) NaCl aqueous solution to evaluate their corrosion performance through electrochemical testing. XRD results showed negligible phase transformation between the powders and the deposited coatings. The WC-NiMoCrFeCo coating exhibited the best sliding wear and electrochemical corrosion performance, with an average specific wear rate value of 3.1 x 10(-8) (mm(3).N-1.m(-1)) and a corrosion current density of 1.9 mu A/cm2. This coating also showed comparable abrasive wear resistance to the WC-CoCr coating. Under erosive wear conditions, too, the WC-FeNiCrMoCu and WC-FeCrAl coatings showed a comparable performance to the benchmark. Dominant wear mechanisms for the reference WC-CoCr coating, under sliding wear conditions, were abrasion (deep grooving) and surface fatigue (crack propagation and pitting). On the contrary, no pitting was observed in WC-NiMoCrFeCo and WC-FeCrAl coatings during the sliding wear test. No considerable difference was identified in the wear mechanisms of the different coatings under abrasion and erosion wear conditions. The results highlight the promise of some of the environment friendly binders studied to replace Co.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy