SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Morshuis P.) "

Sökning: WFRF:(Morshuis P.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Potapov, EV, et al. (författare)
  • 2019 EACTS Expert Consensus on long-term mechanical circulatory support
  • 2019
  • Ingår i: European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. - : Oxford University Press (OUP). - 1873-734X. ; 56:2, s. 230-270
  • Tidskriftsartikel (refereegranskat)abstract
    • Long-term mechanical circulatory support (LT-MCS) is an important treatment modality for patients with severe heart failure. Different devices are available, and many—sometimes contradictory—observations regarding patient selection, surgical techniques, perioperative management and follow-up have been published. With the growing expertise in this field, the European Association for Cardio-Thoracic Surgery (EACTS) recognized a need for a structured multidisciplinary consensus about the approach to patients with LT-MCS. However, the evidence published so far is insufficient to allow for generation of meaningful guidelines complying with EACTS requirements. Instead, the EACTS presents an expert opinion in the LT-MCS field. This expert opinion addresses patient evaluation and preoperative optimization as well as management of cardiac and non-cardiac comorbidities. Further, extensive operative implantation techniques are summarized and evaluated by leading experts, depending on both patient characteristics and device selection. The faculty recognized that postoperative management is multidisciplinary and includes aspects of intensive care unit stay, rehabilitation, ambulatory care, myocardial recovery and end-of-life care and mirrored this fact in this paper. Additionally, the opinions of experts on diagnosis and management of adverse events including bleeding, cerebrovascular accidents and device malfunction are presented. In this expert consensus, the evidence for the complete management from patient selection to end-of-life care is carefully reviewed with the aim of guiding clinicians in optimizing management of patients considered for or supported by an LT-MCS device.
  •  
4.
  • Schenk, S, et al. (författare)
  • IgG classification of anti-PF4/heparin antibodies to identify patients with heparin-induced thrombocytopenia during mechanical circulatory support.
  • 2007
  • Ingår i: Journal of Thrombosis and Haemostasis. - : Elsevier BV. - 1538-7933 .- 1538-7836. ; 5:2, s. 235-41
  • Tidskriftsartikel (refereegranskat)abstract
    • Commercial immunoassays frequently detect anti-PF4/heparin antibodies during mechanical circulatory support (MCS), but only a small minority of patients develops heparin-induced thrombocytopenia (HIT). Whereas platelet functional tests can distinguish between platelet-activating and non-platelet-activating antibodies, commercial PF4-dependent immunoassays do not. Between 2003 and 2004, 113 patients were placed on MCS. Blood samples were obtained on postimplant day 5-7 for analyses by antibody assays and the functional heparin-induced platelet activation (HIPA) assay. Three distinct groups of patient sera were identified: platelet-activating anti-PF4/heparin antibodies (n = 10), non-platelet-activating anti-PF4/heparin antibodies (n = 53), and anti-PF4/heparin antibody negative (n = 50). Patients with platelet-activating antibodies had the highest risk for thromboembolic events (P < 0.005), whereas those with non-platelet-activating antibodies did not differ from antibody negative patients (P = 0.369). The enzyme-immunoassay and column agglutination assays, which cover all immunoglobulin classes, demonstrated adequate sensitivity and negative predictive value; yet, both lacked specificity with respect to the platelet-activating antibodies. If all antibody positive patients were further classified by an IgG-specific anti-PF4/heparin enzyme-immuno assay, specificity for platelet-activating antibodies increased. Whereas IgG-specific optical density (OD) values below 1.0 were likely for non-platelet-activating anti-PF4/heparin antibodies, higher values were progressively predictive for pathogenic platelet activation. The probability of the development of clinical HIT also increased steeply. In conclusion, platelet-activating anti-PF4/heparin antibodies are relatively common (about 9%) in patients on MCS and are associated with significantly higher thrombotic event rates. Low IgG-specific OD values (< 1.0) in the enzyme-immunoassay indicate low likelihood for the presence of platelet-activating antibodies. These results justify further validation so that anticoagulation during MCS becomes safer and adequate.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy