  • Swiderski, L., et al. (författare)
  • Boron-10 loaded BC523A liquid scintillator for neutron detection in the border monitoring
  • 2007
  • Ingår i: 2007 IEEE Nuclear Science Symposium & Medical Imaging Conference. - : IEEE. - 1424409233 - 9781424409235 ; , s. 1389-1395
  • Konferensbidrag (refereegranskat)abstract
    • A BC523A liquid scintillator loaded with boron-10 was tested as a detector for both fast and thermal neutrons. Pulse shape discrimination (PSD) method based on a zero-crossing principle was applied to distinguish between neutron and gamma radiation. High quantum efficiency Photonis XP5500B photomultiplier was used to enhance light detection from the scintillator. This allowed a good registration of the energy spectrum of neutron capture events on boron-10, corresponding to about 60 keVee. The applied PSD method proved to be useful for n/γ discrimination. A good resolving power of the method was achieved even without gating on neutron capture events. A comparison with a standard BC501A liquid scintillator was done to evaluate thermal neutrons detection efficiency in BC523A.
  •  
2.
  • Swiderski, L., et al. (författare)
  • Boron-10 Loaded BC523A Liquid Scintillator for Neutron Detection in the Border Monitoring
  • 2008
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9499 .- 1558-1578. ; 55:6, s. 3710-3716
  • Tidskriftsartikel (refereegranskat)abstract
    • A BC523A liquid scintillator loaded with boron-10 was tested as a detector for both fast and thermal neutrons. A pulse shape discrimination (PSD) method based on a zero-crossing principle was applied to distinguish between neutron and gamma radiation. High quantum efficiency Photonis XP5500B photomultiplier was used to enhance light detection from the scintillator. This allowed a good registration of the energy spectrum of neutron capture events on boron-10, corresponding to about 60 keV gamma-rays. The applied PSD method proved to be useful for n/gamma discrimination. A good resolving power of the method was achieved even without gating on neutron capture events. A comparison with a standard BC501A liquid scintillator was done to evaluate thermal neutrons detection efficiency in BC523A.
  •  
3.
  • Swiderski, L., et al. (författare)
  • Further Study of Boron-10 Loaded Liquid Scintillators for Detection of Fast and Thermal Neutrons
  • 2010
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9499 .- 1558-1578. ; 57:1, s. 375-380
  • Tidskriftsartikel (refereegranskat)abstract
    • Boron-10 loaded liquid scintillators were studied in order to improve n/gamma separation. Pulse shape discrimination (PSD) was implemented by means of a zero-crossing (ZC) method to distinguish between gamma-rays and fast/slow neutrons. Significant progress was done for BC523A2 and EJ339A2 scintillators loaded with reduced amount of B-10 (2% and 2.5%, respectively), as compared to the results obtained earlier with BC523A loaded with 4.4% of B-10. The improvement was probably caused by the reduction of B-10 content, as indicated in the reported study. A B-10 loaded scintillator EJ309B5 based on non- flammable liquid was also studied, showing the best separation of thermal neutron capture events from fast neutrons, gamma-rays and noise.
  •  
4.
  • Swiderski, L., et al. (författare)
  • Further study of Boron-10 loaded liquid scintillators for detection of fast and thermal neutrons
  • 2008
  • Konferensbidrag (refereegranskat)abstract
    • Boron-10 loaded liquid scintillators were studied in order to improve n/γ separation. Pulse shape discrimination (PSD) was done by means of a zero-crossing (ZC) method to distinguish between γ-rays and fast/slow neutrons. A significant progress was achieved for BC523A2 and EJ339A2 loaded with reduced amount of ,10B (2% and 2.5%, respectively), as compared to the results obtained earlier with BC523A loaded with 5% of 10B. The improvement was probably caused by the reduction of 10B content, as indicated in the latter study. A 10B loaded scintillator EJ309B5 based on a non-flammable liquid was also studied, showing the best separation of thermal neutron capture events from fast neutrons, γ-rays and noise.
  •  
5.
  • Szczesniak, T., et al. (författare)
  • A Time Resolution Study of a Continuous Crystal Detector for TOF PET
  • 2010
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 57:1, s. 40-47
  • Tidskriftsartikel (refereegranskat)abstract
    • The majority of current Positron Emission Tomography (PET) systems are based on block-detectors consisting of many scintillating pixels read by a smaller number of photomultipliers (PMTs). An improvement of the time resolution, using a common light readout from a cluster of PMTs, was proposed by Kuhn et al., and tested by us earlier with LSO crystals. This, triggered an idea to design a new PET detector optimized for Time of Flight (TOF) systems, based on continuous crystals. In the present work, we report on optimization of timing with a 20 x 20 x 20 mm(3) LYSO crystal coupled to a 16-channel photomultiplier H8711-200MOD from Hamamatsu. First, measurements were performed of the transit time jitter, the number of photoelectrons and the time resolution using a small 10 x 10 x 5 mm(3) LSO crystal coupled to a H8711-200MOD PMT. Results were compared with data collected from fast timing photomultipliers like Photonis XP1020, XP3060, XP20D0 or Hamamatsu R9800. In the second part of the study, the time resolution measurements and the optimization of the system were made with a continuous LYSO crystal. The final results are discussed in terms of the measured photoelectron number and the requirements for the TOF-PET scanners.
  •  
6.
  •  
7.
  • Swiderski, Lukasz, et al. (författare)
  • Scintillation properties of undoped CsI and CsI doped with CsBr
  • 2008
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 55:3, s. 1241-1245
  • Tidskriftsartikel (refereegranskat)abstract
    • The light output, energy resolution, and nonproportionality characteristics were measured for undoped CsI and several samples of CsI with different doping by CsBr. A correlation between nonproportionality of the light yield and the intrinsic energy resolution was confirmed. Contrary to previously published results the light yield of the tested samples was found to be degraded with increasing bromine concentration. The inspection of light pulse shapes was done by the single photon coincidence method. Decay times of the scintillation pulse were measured for undoped and bromine doped crystals, showing the main scintillation in tens of nanoseconds range.
  •  