1.
  • Mota-Babiloni, A., et al. (författare)
  • Experimental exergy analysis of R513A to replace R134a in a small capacity refrigeration system
  • 2018
  • Ingår i: Energy. - : Elsevier Ltd. - 0360-5442 .- 1873-6785. ; 162, s. 99-110
  • Tidskriftsartikel (refereegranskat)abstract
    • The replacement of HFCs using lower GWP refrigerants in the coming years is a priority to reduce the predicted climate change. The exergy analysis of vapor compression systems can help to identify the feasibility of alternative fluids in existing installations and the potential to improve them. In this sense, this paper presents an exergy analysis of an experimental setup which operates with R134a and the alternative HFO/HFC mixture R513A. The evaporating temperature is ranges between −15 °C and 5 °C, while the condensing temperature is set at 30 °C and 35 °C. In this analysis, the highest amount of exergy destruction rate is obtained at the compressor, followed by the evaporator. The maximum exergy efficiencies are observed at the condenser and the thermostatic expansion device. Finally, the average global exergy efficiency of R513A when replaced R134a in this refrigeration experimental setup is 0.4% higher (absolute difference), and with respect to the components, there is only slight reduction in efficiency in the condenser using R513A. Therefore, the R513A replacement is acceptable according to the second law of thermodynamics. 
  •  
2.
  • Mota-Babiloni, Adrián, et al. (författare)
  • Experimental assessment of R134a and its lower GWP alternative R513A
  • 2017
  • Ingår i: International journal of refrigeration. - : Elsevier. - 0140-7007 .- 1879-2081. ; 74, s. 680-686
  • Tidskriftsartikel (refereegranskat)abstract
    • Lower GWP refrigerants are essential to mitigate the impact of refrigeration systems on climate change. HFO/HFC mixtures are currently considered to replace HFCs in refrigeration and air conditioning systems. The aim of this paper is to present the main operating and performance differences between R513A (GWP of 573) and R134a (GWP of 1300), the most used refrigerants for medium evaporation temperature refrigeration systems and mobile air conditioners. To perform the experimental comparison, 36 tests are carried out with each refrigerant at evaporating temperatures between −15 and 12.5°C and condensing temperatures between 25 and 35°C. The conclusion of the experimental comparison is that R513A can substitute R134a with only a thermostatic expansion valve adjustment, achieving better performance and higher cooling capacity. The discharge temperature of R513A is always lower than that of R134a.
  •  
3.
  • Mota-Babiloni, Adrián, et al. (författare)
  • Refrigerant R32 as lower GWP working fluid in residential air conditioning systems in Europe and the USA
  • 2017
  • Ingår i: Renewable & sustainable energy reviews. - : Elsevier. - 1364-0321 .- 1879-0690. ; 80, s. 1031-1042
  • Forskningsöversikt (refereegranskat)abstract
    • Because air conditioning and heat pump systems contribute greatly to greenhouse gas emissions, equipment with both lower global warming potential (GWP) working fluids and a higher level of performance should be used. R32 (difluoromethane) has been proposed to substitute R410A, particularly in residential air conditioning (RAC) systems. This study collected the most relevant and recent researches into R32 as a refrigerant so as to assess its viability in RAC systems in both Europe and the USA, as compared to R410A and other lower GWP RAC alternatives. The R32 value of GWP is 677, which is below the F-gas regulation limit in RAC equipment (750). According to ASHRAE standard 34, R32 is less flammable than hydrocarbons, and the amount of charge permitted for R32 is above the necessary level in RAC equipment. It can be concluded that R32 has significantly good heat transfer characteristics and a level of performance that make it acceptable at low condensing temperatures, thereby avoiding overly high compressor discharge temperatures. Its performance is very similar to that of R410A across the entire operating range, and it is therefore believed that R32 will be utilized in RAC systems in the remaining countries that prioritize lower GWP fluids but are less strict in their security regulations. To replace R410A under extreme conditions, some system modifications can be conducted, or R32 mixtures with hydrofluoroolefins (HFOs) can be used. Such mixtures achieve a lower performance than R32, but are acceptable replacements when considering their lower GWP compared to that of R32, and similar level of flammability. Finally, other (R32-based) alternative mixtures have also been developed and their behaviours studied under a wide range of operating conditions.
  •  