SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Neef Markus) "

Sökning: WFRF:(Neef Markus)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hess, Timo, et al. (författare)
  • Dissecting the genetic heterogeneity of gastric cancer
  • 2023
  • Ingår i: EBioMedicine. - : Elsevier. - 2352-3964. ; 92
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Gastric cancer (GC) is clinically heterogenous according to location (cardia/non-cardia) and histopathology (diffuse/intestinal). We aimed to characterize the genetic risk architecture of GC according to its subtypes. Another aim was to examine whether cardia GC and oesophageal adenocarcinoma (OAC) and its precursor lesion Barrett's oesophagus (BO), which are all located at the gastro-oesophageal junction (GOJ), share polygenic risk architecture.Methods: We did a meta-analysis of ten European genome-wide association studies (GWAS) of GC and its subtypes. All patients had a histopathologically confirmed diagnosis of gastric adenocarcinoma. For the identification of risk genes among GWAS loci we did a transcriptome-wide association study (TWAS) and expression quantitative trait locus (eQTL) study from gastric corpus and antrum mucosa. To test whether cardia GC and OAC/BO share genetic aetiology we also used a European GWAS sample with OAC/BO.Findings: Our GWAS consisting of 5816 patients and 10,999 controls highlights the genetic heterogeneity of GC according to its subtypes. We newly identified two and replicated five GC risk loci, all of them with subtype-specific association. The gastric transcriptome data consisting of 361 corpus and 342 antrum mucosa samples revealed that an upregulated expression of MUC1, ANKRD50, PTGER4, and PSCA are plausible GC-pathomechanisms at four GWAS loci. At another risk locus, we found that the blood-group 0 exerts protective effects for non-cardia and diffuse GC, while blood-group A increases risk for both GC subtypes. Furthermore, our GWAS on cardia GC and OAC/BO (10,279 patients, 16,527 controls) showed that both cancer entities share genetic aetiology at the polygenic level and identified two new risk loci on the single-marker level.Interpretation: Our findings show that the pathophysiology of GC is genetically heterogenous according to location and histopathology. Moreover, our findings point to common molecular mechanisms underlying cardia GC and OAC/BO. 
  •  
2.
  • Waltenberger, Johannes, et al. (författare)
  • Five-Year Results of the Bioflow-III Registry : Real-World Experience with a Biodegradable Polymer Sirolimus-Eluting Stent
  • 2020
  • Ingår i: Cardiovascular Revascularization Medicine. - : Elsevier. - 1553-8389 .- 1878-0938. ; 21:1, s. 63-69
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: We aimed to assess long-term safety and performance of the Orsiro sirolimus-eluting coronary stent with biodegradable polymer in a large unselected population and in pre-specified subgroups.Methods: BIOFLOW-III is a prospective, multicenter, international, observational registry with follow-up visits scheduled at 6 and 12 months, and at 3 and 5 years (NCT01553526).Results: 1356 patients with 1738 lesions were enrolled. Of those, 392 (28.9%) declined to participate in the study extension from 18 months to 5 years, 37 (2.7%) withdrew consent, and 89 (6.6%) were lost to follow-up. At 5-years, Kaplan-Meier estimates of target lesion failure, defined as a composite of cardiac death, target-vessel myocardial infarction, coronary artery bypass grafting and clinically driven target lesion revascularization was 10.0% [95% confidence interval (CI): 8.4; 12.0] in the overall population, and 14.0% [95% CI: 10.5; 18.6], 10.3% [95% CI: 7.8; 13.5], 1.8% [95% CI: 0.3; 12.0], and 11.3% [95% CI: 8.5; 15.1] in the pre-defined risk groups of patients with diabetes mellitus, small vessels <= 2.75 mm, chronic total occlusion, and acute myocardial infarction. Definite stent thrombosis was observed in 0.3% [95% CI: 0.1; 0.9] of patients.Conclusion: These long-term outcomes provide further evidence on the safety and performance of a sirolimus-eluting biodegradable polymer stent within daily clinical practice. The very lowdefinite stent thrombosis rate affirms biodegradable polymer safety and performance.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy