SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Neel Bastien) "

Sökning: WFRF:(Neel Bastien)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Neel, Bastien, et al. (författare)
  • Camping Burner-Based Flame Emission Spectrometer for Classroom Demonstrations
  • 2014
  • Ingår i: Journal of Chemical Education. - : American Chemical Society (ACS). - 0021-9584 .- 1938-1328. ; 91:10, s. 1655-1660
  • Tidskriftsartikel (refereegranskat)abstract
    • A flame emission spectrometer was built in-house for the purpose of introducing this analytical technique to students at the high school level. The aqueous sample is sprayed through a homemade nebulizer into the air inlet of a consumer-grade propane camping burner. The resulting flame is analyzed by a commercial array spectrometer for the visible spectrum in the range of 350-1000 nm. The cost of the instrument is mainly given by that of the spectrometer and computer/projector. The obtained emission spectrum is characteristic of each individual atom, such as sodium (589 nm) and potassium (766 nm), or molecule, such as calcium hydroxide (554 and 622 nm). The readout signal (either peak height or peak area) is shown to be proportional to the sample concentration. Both qualitative and quantitative analyses may be performed with this robust and low-cost device. Samples can be rapidly changed, giving a 95% response time of under 3 s. The analytical figures of merit were characterized for calcium, potassium, and sodium in different water samples, and the resulting precision (standard deviation) for a 1 s acquisition time was typically on the order of 2%. Observed calcium levels were lower than expected because of the presence of refractory compounds, such as calcium phosphate or sulfate, that are difficult to fully atomize with the simple flame used here. Lanthanum(III) chloride was successfully used to increase the calcium response. The lower limit of detection for sodium was approximately 3 ppb and comparable to that of conventional commercial emission spectrometers.
  •  
4.
  • Neel, Bastien, et al. (författare)
  • Nitrite-Selective Electrode Based On Cobalt( II) tert-ButylSalophen Ionophore
  • 2014
  • Ingår i: Electroanalysis. - : John Wiley & Sons. - 1040-0397 .- 1521-4109. ; 26:3, s. 473-480
  • Tidskriftsartikel (refereegranskat)abstract
    • A series of polymeric nitrite-selective electrodes containing a new lipophilic ionophore Co(II) tert-butyl-salophen is reported. The stability of Co(II) ionophores within a PVC-based membrane was investigated by leaching experiments. Different membrane compositions were explored in order to reach the lowest possible limit of detection for a PVC-based nitrite selective polymeric membrane electrode containing this ionophore. The optimal electrode showed a limit of detection of 2x10(-6)M and exhibited four orders of magnitude of discrimination over nitrate, chloride and bromide. The electrodes were evaluated in undiluted human urine and attest to the robustness of the ionophore.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy