SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Nielsen Niels Erik) "

Sökning: WFRF:(Nielsen Niels Erik)

  • Resultat 1-10 av 79
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Allentoft, Morten E., et al. (författare)
  • 100 ancient genomes show repeated population turnovers in Neolithic Denmark
  • 2024
  • Ingår i: Nature. - 0028-0836 .- 1476-4687. ; 625, s. 329-337
  • Tidskriftsartikel (refereegranskat)abstract
    • Major migration events in Holocene Eurasia have been characterized genetically at broad regional scales1–4. However, insights into the population dynamics in the contact zones are hampered by a lack of ancient genomic data sampled at high spatiotemporal resolution5–7. Here, to address this, we analysed shotgun-sequenced genomes from 100 skeletons spanning 7,300 years of the Mesolithic period, Neolithic period and Early Bronze Age in Denmark and integrated these with proxies for diet (13C and 15N content), mobility (87Sr/86Sr ratio) and vegetation cover (pollen). We observe that Danish Mesolithic individuals of the Maglemose, Kongemose and Ertebølle cultures form a distinct genetic cluster related to other Western European hunter-gatherers. Despite shifts in material culture they displayed genetic homogeneity from around 10,500 to 5,900 calibrated years before present, when Neolithic farmers with Anatolian-derived ancestry arrived. Although the Neolithic transition was delayed by more than a millennium relative to Central Europe, it was very abrupt and resulted in a population turnover with limited genetic contribution from local hunter-gatherers. The succeeding Neolithic population, associated with the Funnel Beaker culture, persisted for only about 1,000 years before immigrants with eastern Steppe-derived ancestry arrived. This second and equally rapid population replacement gave rise to the Single Grave culture with an ancestry profile more similar to present-day Danes. In our multiproxy dataset, these major demographic events are manifested as parallel shifts in genotype, phenotype, diet and land use.
  •  
2.
  • Allentoft, Morten E., et al. (författare)
  • Population genomics of post-glacial western Eurasia
  • 2024
  • Ingår i: Nature. - 0028-0836 .- 1476-4687. ; 625:7994, s. 301-311
  • Tidskriftsartikel (refereegranskat)abstract
    • Western Eurasia witnessed several large-scale human migrations during the Holocene1–5. Here, to investigate the cross-continental effects of these migrations, we shotgun-sequenced 317 genomes—mainly from the Mesolithic and Neolithic periods—from across northern and western Eurasia. These were imputed alongside published data to obtain diploid genotypes from more than 1,600 ancient humans. Our analyses revealed a ‘great divide’ genomic boundary extending from the Black Sea to the Baltic. Mesolithic hunter-gatherers were highly genetically differentiated east and west of this zone, and the effect of the neolithization was equally disparate. Large-scale ancestry shifts occurred in the west as farming was introduced, including near-total replacement of hunter-gatherers in many areas, whereas no substantial ancestry shifts happened east of the zone during the same period. Similarly, relatedness decreased in the west from the Neolithic transition onwards, whereas, east of the Urals, relatedness remained high until around 4,000 bp, consistent with the persistence of localized groups of hunter-gatherers. The boundary dissolved when Yamnaya-related ancestry spread across western Eurasia around 5,000 bp, resulting in a second major turnover that reached most parts of Europe within a 1,000-year span. The genetic origin and fate of the Yamnaya have remained elusive, but we show that hunter-gatherers from the Middle Don region contributed ancestry to them. Yamnaya groups later admixed with individuals associated with the Globular Amphora culture before expanding into Europe. Similar turnovers occurred in western Siberia, where we report new genomic data from a ‘Neolithic steppe’ cline spanning the Siberian forest steppe to Lake Baikal. These prehistoric migrations had profound and lasting effects on the genetic diversity of Eurasian populations.
  •  
3.
  • De Backer, Ole, et al. (författare)
  • Efficacy and safety of the Lotus Valve System for treatment of patients with severe aortic valve stenosis and intermediate surgical risk: Results from the Nordic Lotus-TAVR registry
  • 2016
  • Ingår i: International Journal of Cardiology. - : Elsevier. - 0167-5273 .- 1874-1754. ; 219, s. 92-97
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Transcatheter aortic valve replacement (TAVR) has becomean established therapeutic option for patients with symptomatic, severe aortic valve stenosis (AS) who are ineligible or at high risk for conventional valvular surgery. In Northwestern Europe, the TAVR technology is also increasingly used to treat patients with an intermediate risk profile. Methods and results: The study was designed as an independent Nordic multicenter registry of intermediate risk patients treated with the Lotus Valve System (Boston Scientific, MA, USA; N = 154). Valve Academic Research Consortium (VARC)-defined device success was obtained in 97.4%. A Lotus Valve was successfully implanted in all patients. There was no valve migration, embolization, ectopic valve deployment, or TAV-in-TAV deployment. The VARC-defined combined safety rate at 30 days was 92.2%, with a mortality rate of 1.9% and stroke rate of 3.2%. The clinical efficacy rate after 30 days was 91.6% - only one patient had moderate aortic regurgitation. When considering only those patients in the late experience group (N=79), the combined safety and clinical efficacy rates were 93.7% and 92.4%, respectively. The pacemaker implantation rate was 27.9% - this rate was 12.8% in case of a combined implantation depth amp;lt;4 mm and a device/annulus ratio amp;lt; 1.05. Conclusions: The present study demonstrates the efficacy and safety of the repositionable, retrievable Lotus Valve System in intermediate risk patients with AS. The VARC-defined device success rate was 97.4% with a 30-day patient safety and clinical efficacy rate of more than 90%. Less than moderate aortic regurgitation was obtained in 99.4% of patients. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
  •  
4.
  • Eriksson, Peter J, 1959, et al. (författare)
  • Transcatheter Intervention for Coarctation of the Aorta A Nordic Population-Based Registry With Long-Term Follow-Up
  • 2023
  • Ingår i: Jacc-Cardiovascular Interventions. - : Elsevier BV. - 1936-8798 .- 1876-7605. ; 16:4, s. 444-453
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND Coarctation of the aorta (CoA), a congenital narrowing of the proximal descending thoracic aorta, is a relatively common form of congenital heart disease. Untreated significant CoA has a major impact on morbidity and mortality. In the past 3 decades, transcatheter intervention (TCI) for CoA has evolved as an alternative to surgery.OBJECTIVES The authors report on all TCIs for CoA performed from 2000 to 2016 in 4 countries covering 25 million inhabitants, with a mean follow-up duration of 6.9 years.METHODS During the study period, 683 interventions were performed on 542 patients.RESULTS The procedural success rate was 88%, with 9% considered partly successful. Complications at the intervention site occurred in 3.5% of interventions and at the access site in 3.5%. There was no in-hospital mortality. During follow-up, TCI for CoA reduced the presence of hypertension significantly from 73% to 34%, but despite this, many patients remained hypertensive and in need of continuous antihypertensive treatment. Moreover, 8% to 9% of patients needed aortic and/or aortic valve surgery during follow-up.CONCLUSIONS TCI for CoA can be performed with a low risk for complications. Lifetime follow-up after TCI for CoA seems warranted. (J Am Coll Cardiol Intv 2023;16:444-453) & COPY; 2023 by the American College of Cardiology Foundation.
  •  
5.
  • Ihlberg, Leo, et al. (författare)
  • Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries
  • 2013
  • Ingår i: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier. - 0022-5223 .- 1097-685X. ; 146:5, s. 1047-1054
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Transcatheter valve-in-valve implantation has emerged as an option, in addition to reoperative surgical aortic valve replacement, to treat failed biologic heart valve substitutes. However, the clinical experience with this approach is still limited. We report the comprehensive experience of transcatheter valve-in-valve implantation in the Nordic countries from May 2008 to January 2012. less thanbrgreater than less thanbrgreater thanMethods: A total of 45 transcatheter aortic valve-in-valve implantations were performed during the study period in 11 centers. The mean age of the patients was 80.6 years (range, 61-91), 26 were male and 19 were female, and the mean EuroSCORE, EuroSCORE II, and Society of Thoracic Surgeons score was 35.4, 16.3, and 14.6, respectively. The type of failure was stenosis and combined in 58% (mean and peak aortic valve gradient, 77 and 45 mm Hg, respectively) and regurgitation in 42% of cases. The SAPIEN/XT (Edwards LifeSciences, Irvine, Calif) and CoreValve (Medtronic Inc, Minneapolis, Minn) system was used in 33 and 12 cases, respectively. The access route was transapical in 25, transfemoral in 17, transaortic in 2, and subclavian in 1 case. The mean follow-up was 14.4 months. The periprocedural and postoperative outcomes were assessed using the Valve Academic Research Consortium criteria. less thanbrgreater than less thanbrgreater thanResults: No intraprocedural mortality occurred. The technical success rate was 95.6% (1 second valve implantation, 1 conversion to open surgery). The all-cause 30-day mortality was 4.4% (1 cardiac-related and 1 aspiration pneumonia). The major complications within 30 days included stroke in 2.2%, periprocedural myocardial infarction in 4.4%, and major vascular complication in 2.2% of patients. At 1 month, all but 1 patient had either no or mild paravalvular leakage, with a mean and peak valve gradient of 17 mm Hg (range, 4-38) and 30 mm Hg (range, 7-68), respectively. The mean gradient was greater than 20 mm Hg in 17% of patients and remained unchanged at 12 months. The 1-year survival was 88.1%. less thanbrgreater than less thanbrgreater thanConclusions: Transcatheter valve-in-valve implantation is widely performed, albeit in small numbers, in most centers in the Nordic countries. The short-termresults were excellent in this high-risk patient population, demonstrating a low incidence of device-or procedure-related complications. However, a considerable number of patients were left with suboptimal systolic valve performance with unknown long-term effects, warranting close surveillance after transcatheter valve-in-valve implantation.
  •  
6.
  • Ahn, Henrik Casimir, et al. (författare)
  • Can predilatation in transcatheter aortic valve implantation be omitted? - a prospective randomized study
  • 2016
  • Ingår i: Journal of Cardiothoracic Surgery. - : BIOMED CENTRAL LTD. - 1749-8090. ; 11:124
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The use of a balloon expandable stent valve includes balloon predilatation of the aortic stenosis before valve deployment. The aim of the study was to see whether or not balloon predilatation is necessary in transcatheter aortic valve replacement (TAVI). Methods: Sixty consecutive TAVI patients were randomized to the standard procedure or to a protocol where balloon predilatation was omitted. Results: There were no significant differences between the groups regarding early hemodynamic results or complication rates. Conclusions: TAVI can be performed safely without balloon predilatation and with the same early results as achieved with the standard procedure including balloon predilatation. The reduction in the number of pacing periods required may be beneficial for the patient.
  •  
7.
  • Ahn, Henrik Casimir, et al. (författare)
  • Transvenous Implantation of a Stent Valve in Patients With Degenerated Mitral Prostheses and Native Mitral Stenosis
  • 2016
  • Ingår i: Annals of Thoracic Surgery. - : Elsevier. - 0003-4975 .- 1552-6259. ; 101:6, s. 2279-2284
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The purpose of this study was to report the use of a transvenous transseptal approach using a stent valve in patients with degenerated biological mitral valve prostheses, regurgitation after mitral repair, and native mitral stenosis.METHODS: Ten patients (median age, 74 years; range, 20-89 years; 5 men and 5 women) with degenerated mitral bioprosthetic valves (n = 7), failed mitral repair (n = 1), or calcified native stenotic valves (n = 2) underwent transvenous implantation of a stent valve.RESULTS: The procedure was initially successful in all patients. Predilation was performed for balloon sizing only in the 2 patients with native mitral stenosis. The stent valve was deployed during 1 period of rapid pacing. A guidewire, as a loop from the right femoral vein and through the left ventricular apex, facilitated a good angle and secure positioning of the stent valve. An ultrasonographically guided puncture of the apex was carried out in 6 patients, and in the other 4 we performed a minithoracotomy before apical puncture. All valves were implanted in a good position with improved function and without significant paravalvular leakage (PVL). There were no periprocedural deaths. The 30-day survival was 80% (8 of 10 patients), and 60% (6 of 10) of patients were still alive a median time of 290 days after the procedure.CONCLUSIONS: Transvenous transseptal implantation of a stent valve was performed in 10 patients with mitral valve disease, with good early functional results. These high-risk patients must be carefully selected by a multidisciplinary team because the procedure carries a high mortality.
  •  
8.
  •  
9.
  • Appel, Carl-Fredrik, et al. (författare)
  • Transcatheter versus surgical treatment for aortic stenosis : Patient selection and early outcome
  • 2012
  • Ingår i: Scandinavian Cardiovascular Journal. - : Informa Healthcare. - 1401-7431 .- 1651-2006. ; 46:5, s. 301-307
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives. To describe short-term clinical and echocardiography outcomes in patients undergoing transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). To explore patient selection criteria for treatment with TAVI. Design. TAVI patients (n = 45) were matched to SAVR patients (n = 45) with respect to age within +/- 10 years, sex and systolic left ventricular function. Results. TAVI patients were older, 82 +/- 8 versus 78 +/- 5 years (p = 0.005) and they had higher logEuroSCORE, 16 +/- 11% versus 8 +/- 4% (p andlt; 0.001). There were no significant differences in 30 days mortality, stroke and myocardial infarction. TAVI patients received less erythrocyte (53% vs. 78%, p = 0.03) and thrombocyte (7% vs. 27%, p = 0.02) transfusions. Postoperative atrial fibrillation was less common (18% vs. 60%, p andlt; 0.001) in the TAVI group. Paravalvular regurgitation was more common in TAVI patients (87% vs. 0%, p andlt; 0.001) and 27% had access site complications. Aortic transvalvular velocity was 2.3 +/- 0.4 m/s versus 2.6 +/- 0.5 m/s (p = 0.002) and mean valve pressure gradient was 12 +/- 4 mmHg versus 15 +/- 5 mmHg (p = 0.01) in the TAVI and SAVR groups, respectively. Twenty-nine (64%) of the TAVI patients had logEuroSCORE andlt; 15%. Conclusions. Both TAVI and SAVR have good short term clinical outcome with excellent hemodynamic result. In clinical practice, factors other than high logEuroSCORE play an important role in patient selection for TAVI.
  •  
10.
  • Baranowski, Jacek, et al. (författare)
  • A simplified protocol for transcatheter aortic valve implantation that reduces procedure-related risk
  • 2016
  • Ingår i: Journal of Cardiovascular Diseases & Diagnosis. - : Omics Publishing Group. - 2329-9517. ; 4:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Transcatheter Aortic Valve Implantation is now a well-established procedure and continuous development has improved the technique. The object of this paper is to describe the successive steps taken at our department to improve our protocol, resulting in a more effective and patient-safe procedure.Design: An echo-guided method for aortic cusp alignment was used in 229 patients. In 139 patients pre-dilatation was excluded from the protocol. In the last 47 of the patients we exchanged the stiff guide-wire in the left ventricle with a soft wire for valve placement.Results: There was a significant decrease in the use of contrast medium during the period with 90% of patients receiving less than 50 ml contrast and 35% no contrast at all. In more than half the patients we only used rapid pacing in association with deployment of the stent valve. We had six cases ofpericardial bleeding due to penetration of the stiff guide wire through the left ventricular (LV) wall. This complication was avoided in all subsequent patients where we exchanged the stiff catheter to a soft guidewire in the ascending aorta before introduction of the wire and stent valve into the LV.Conclusions: We have successively modified our standard protocol for implantation of a balloon-expandable transcatheter aortic valve. This has simplified the procedure and reduced the risk for certain procedure-related complications.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 79
Typ av publikation
tidskriftsartikel (60)
konferensbidrag (12)
annan publikation (4)
doktorsavhandling (3)
Typ av innehåll
refereegranskat (68)
övrigt vetenskapligt/konstnärligt (11)
Författare/redaktör
Nielsen, Niels Erik (57)
Baranowski, Jacek (19)
Christersson, Christ ... (13)
Swahn, Eva (12)
Wallby, Lars (11)
Johansson, Bengt (11)
visa fler...
Dellborg, Mikael, 19 ... (10)
Nylander, Eva (10)
Rönning, Helén (8)
Ahn, Henrik (8)
Strömberg, Anna (7)
Salomaa, Veikko (6)
Lind, Lars (6)
Sattar, Naveed (6)
Swahn, Eva, 1949- (6)
Deloukas, Panos (6)
Franks, Paul W. (6)
Laakso, Markku (6)
McCarthy, Mark I (6)
Bork-Jensen, Jette (6)
Brandslund, Ivan (6)
Linneberg, Allan (6)
Grarup, Niels (6)
Pedersen, Oluf (6)
Hansen, Torben (6)
Langenberg, Claudia (6)
Boehnke, Michael (6)
Mohlke, Karen L (6)
Zhao, Wei (6)
Rasheed, Asif (6)
Saleheen, Danish (6)
Dahlin, Lars-Göran (6)
Mahajan, Anubha (6)
Palmer, Colin N. A. (6)
Rolandsson, Olov (5)
Perola, Markus (5)
Wareham, Nicholas J. (5)
Kuusisto, Johanna (5)
Ridker, Paul M. (5)
Chasman, Daniel I. (5)
Tuomilehto, Jaakko (5)
Thorleifsson, Gudmar (5)
Thorsteinsdottir, Un ... (5)
Stefansson, Kari (5)
Rotter, Jerome I. (5)
Samani, Nilesh J. (5)
Spector, Timothy D (5)
Luan, Jian'an (5)
Caulfield, Mark J. (5)
Munroe, Patricia B. (5)
visa färre...
Lärosäte
Linköpings universitet (63)
Uppsala universitet (22)
Lunds universitet (22)
Umeå universitet (19)
Göteborgs universitet (17)
Karolinska Institutet (17)
visa fler...
Jönköping University (5)
Mittuniversitetet (3)
Luleå tekniska universitet (2)
Kungliga Tekniska Högskolan (1)
Örebro universitet (1)
Linnéuniversitetet (1)
visa färre...
Språk
Engelska (78)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (53)
Naturvetenskap (4)
Teknik (2)
Humaniora (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy