SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Nwaboh Javis) "

Sökning: WFRF:(Nwaboh Javis)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Anyangwe Nwaboh, Javis, et al. (författare)
  • Metrological quantification of CO in biogas using laser absorption spectroscopy and gas chromatography
  • 2018
  • Ingår i: Measurement science and technology. - : IOP Publishing. - 0957-0233 .- 1361-6501. ; 29:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Biogas has a vital role in the future market of renewable energy. When upgraded to biomethane, it can be injected into natural gas grids if the level of certain impurities complies with the specifications in EN16723. For some of these impurities, suitable measurement methods are lacking which hampers the quality control of biomethane to be injected into natural gas networks. Here, we report the evaluation of three detection methods suitable for carbon monoxide (CO) in biogas and biomethane applications for which EN16723 specifies an upper limit of 0.1% (1000 µmol/mol). Two of these methods are based on laser absorption spectroscopy (LAS) and one on gas chromatography (GC). Both LAS spectrometers are employing direct absorption spectroscopy and operating at 4.6µm, probing a single CO absorption line in the fundamental CO band: One – called dTDLAS (direct tunable diode laser absorption spectroscopy)- is based on a new Interband Cascade Laser specially designed for biogas and biomethane applications, while the other is based on Quantum Cascade Laser Absorption Spectroscopy (QCLAS). The GC is equipped with two packed columns (Hayesep Q and Molecular Sieve 5A) and a thermal conductivity detector. Carbon monoxide amount fraction results in biogas matrices derived using these three measurement methods are compared to amount fraction values of different, gravimetrically prepared reference gas standards of CO in biogas. These were used to validate the measurement capabilities. The measured CO amount fraction results from LAS and GC covered 10 µmol/mol to 30000 µmol/mol (system measurement ranges, LAS: 3 µmol/mol - 1000 µmol/mol, GC: 500 µmol/mol - 30000 µmol/mol) and were in excellent agreement with the gravimetric values of the gas standards. At 400 µmol/mol, the guide to the expression of uncertainty in measurement (GUM) compliant relative standard uncertainties of our calibration-free dTDLAS and the gas-calibrated QCLAS systems are estimated to be 1.4 % vs 0.5 %, respectively. The relative standard uncertainty of the GC CO measurements at 5075 µmol/mol is 1.3 %. This work demonstrates that, by means of GC and LAS, relative standard uncertainties of 1.4 % and below can be reached for CO measurements in biogas and that cost-optimized calibration-free approaches not requiring frequent use of gas standards have become available.
  •  
2.
  • Arrhenius, Karine, et al. (författare)
  • Need for a protocol for performance evaluation of the gas analyzers used in biomethane conformity assessment
  • 2024
  • Ingår i: Accreditation and Quality Assurance. - : Springer Science and Business Media Deutschland GmbH. - 0949-1775 .- 1432-0517. ; 29:1, s. 69-76
  • Tidskriftsartikel (refereegranskat)abstract
    • Biomethane may contain trace components that can have adverse effects on gas vehicles performances and on the pipelines when injected in the gas grid. Biomethane quality assurance against specifications is therefore crucial for the integrity of the end-users’ appliances. Analytical methods used to assess biomethane conformity assessment must be validated properly and possibly, new methods specifically for biomethane should be developed. This paper provides an overview of the biomethane quality assurance infrastructure and the challenges faced with focus on sampling, analysis methods, reference gas mixtures, and performance evaluation. Currently, requirements for analytical method validation and fit-for-purpose assessments do not exist for biomethane. The industry is in urgent need of a protocol to evaluate the fit-for-purpose of methods in a harmonized manner. Reference gas mixtures to check the accuracy of the instrument and to determine the traceability of the measurement are also urgently required. 
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Arrhenius, Karine (2)
Anyangwe Nwaboh, Jav ... (1)
Persijn, Stefan (1)
Bohlen, Haleh (1)
Werhahn, Olav (1)
Ebert, Volker (1)
visa fler...
Culleton, Lucy (1)
Nwaboh, Javis (1)
Li, Jianrong (1)
visa färre...
Lärosäte
RISE (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Teknik (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy