SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(O'Doherty Michael J) "

Sökning: WFRF:(O'Doherty Michael J)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Barrington, Sally F, et al. (författare)
  • PET-CT for staging and early response : results from the Response-Adapted Therapy in Advanced Hodgkin Lymphoma study.
  • 2016
  • Ingår i: Blood. - : American Society of Hematology. - 0006-4971 .- 1528-0020. ; 127:12, s. 1531-1538
  • Tidskriftsartikel (refereegranskat)abstract
    • International guidelines recommend that positron emission tomography-computed tomography (PET-CT) should replace CT in Hodgkin lymphoma (HL). The aims of this study were to compare PET-CT with CT for staging and measure agreement between expert and local readers, using a 5-point scale (Deauville criteria), to adapt treatment in a clinical trial: Response-Adapted Therapy in Advanced Hodgkin Lymphoma (RATHL). Patients were staged using clinical assessment, CT, and bone marrow biopsy (RATHL stage). PET-CT was performed at baseline (PET0) and after 2 chemotherapy cycles (PET2) in a response-adapted design. PET-CT was reported centrally by experts at 5 national core laboratories. Local readers optionally scored PET2 scans. The RATHL and PET-CT stages were compared. Agreement among experts and between expert and local readers was measured. RATHL and PET0 stage were concordant in 938 (80%) patients. PET-CT upstaged 159 (14%) and downstaged 74 (6%) patients. Upstaging by extranodal disease in bone marrow (92), lung (11), or multiple sites (12) on PET-CT accounted for most discrepancies. Follow-up of discrepant findings confirmed the PET characterization of lesions in the vast majority. Five patients were upstaged by marrow biopsy and 7 by contrast-enhanced CT in the bowel and/or liver or spleen. PET2 agreement among experts (140 scans) with a κ (95% confidence interval) of 0.84 (0.76-0.91) was very good and between experts and local readers (300 scans) at 0.77 (0.68-0.86) was good. These results confirm PET-CT as the modern standard for staging HL and that response assessment using Deauville criteria is robust, enabling translation of RATHL results into clinical practice.
  •  
2.
  • Barrington, Sally F., et al. (författare)
  • Concordance between four European centres of PET reporting criteria designed for use in multicentre trials in Hodgkin lymphoma
  • 2010
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 37:10, s. 1824-1833
  • Tidskriftsartikel (refereegranskat)abstract
    • To determine if PET reporting criteria for the Response Adapted Treatment in Hodgkin Lymphoma (RATHL) trial could enable satisfactory agreement to be reached between 'core' laboratories operating in different countries. Four centres reported scans from 50 patients with stage II-IV HL, acquired before and after two cycles of Adriamycin/bleomycin/vinblastine/dacarbazine. A five-point scale was used to score response scans using 'normal' mediastinum and liver as reference levels. Centres read scans independently of each other. The level of agreement between centres was determined assuming (1) that uptake in sites involved at diagnosis that was higher than liver uptake represented disease (conservative reading), and (2) that uptake in sites involved at diagnosis that was higher than mediastinal uptake represented disease (sensitive reading). There was agreement that the response scan was 'positive' or 'negative' for lymphoma in 44 patients with a conservative reading and in 41 patients with a sensitive reading. Kappa was 0.85 (95% CI 0.74-0.96) for conservative reading and 0.79 (95% CI 0.67-0.90) for sensitive reading. Agreement was reached in 46 and 44 patients after discussion for the conservative and sensitive readings, respectively. The criteria developed for reporting in the RATHL trial are sufficiently robust to be used in a multicentre setting.
  •  
3.
  • Sharma, Rohini, et al. (författare)
  • Multicenter Reproducibility of F-18-Fluciclatide PET Imaging in Subjects with Solid Tumors
  • 2015
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 56:12, s. 1855-1861
  • Tidskriftsartikel (refereegranskat)abstract
    • Integrins are upregulated on both tumor cells and associated vasculature, where they play an important role in angiogenesis and metastasis. Fluciclatide is an arginine-glycine-aspartic acid peptide with high affinity for alpha(v)beta(3)/alpha(v)beta(5) integrin, which can be radio-labeled for PET imaging of angiogenesis. Thus, F-18-fluciclatide is a potential biomarker of therapeutic response to antiangiogenic inhibitors. The aim of this study was to evaluate the reproducibility of F-18-fluciclatide in multiple solid-tumor types. Methods: Thirty-nine patients underwent PET/CT scanning at 40, 65, and 90 min after injection of F-18-fluciclatide (maximum, 370 MBq) on 2 separate days (2-9 d apart). Patients did not receive any therapy between PET/CT scans. F-18-fluciclatide images were reported and quantitative measures of uptake were extracted using the PERCIST methodology. Intrasubject reproducibility of PET uptake in all measurable lesions was evaluated by calculating relative differences in SUV between PET scans for each lesion during the 2 imaging sessions. Results: Thirty-nine measurable lesions were detected in 26 patients. Lesion uptake correlated strongly across imaging sessions (r = 0.92, P < 0.05, at 40 min; r = 0.94, P < 0.05, at 65 min; r = 0.94, P, 0.05, at 90 min) with a mean relative difference and SD of the relative difference of 0.006 +/- 0.18 at 40 min, 0.003 +/- 0.19 at 65 min, and 0.025 +/- 0.20 at 90 min. This reflects 95% limits of repeatability of 35%-39% for the difference between the 2 SUV measurements or a variability of 18%-20% in agreement from that observed in well-calibrated multicenter F-18-FDG studies. Conclusion: The test-retest reproducibility of F-18-fluciclatide across multiple tumor types has been measured and shown to be acceptable. This is an important step in the development of this in vivo biomarker to identify and quantify response to antiangiogenic therapy in cancer patients.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy