1. |
- van den Berg, Victor J, et al.
(författare)
-
IgM anti-malondialdehyde low density lipoprotein antibody levels indicate coronary heart disease and necrotic core characteristics in the Nordic Diltiazem (NORDIL) study and the Integrated Imaging and Biomarker Study 3 (IBIS-3)
- 2018
-
Ingår i: EBioMedicine. - : Elsevier BV. - 2352-3964. ; 36, s. 63-72
-
Tidskriftsartikel (refereegranskat)abstract
- Background: Certain immunoglobulins (Ig) are proposed to have protective functions in atherosclerosis.Objectives: We tested whether serum levels of IgG and IgM autoantibodies against malondialdehyde low density lipoprotein (MDA-LDL) are associated with clinical coronary heart disease (CHD) and unfavorable plaque characteristics.Methods: NORDIL was a prospective study investigating adverse cardiovascular outcomes in hypertensive patients. IBIS-3 analyzed lesions in a non-culprit coronary artery with <50% stenosis using radiofrequency intravascular ultrasound (RF-IVUS) and near-infrared spectroscopy (NIRS). Imaging was repeated after a median of 386?days on rosuvastatin. Associations of antibodies with incident CHD and imaging parameters were assessed in the two sub-studies respectively.Findings: From 10,881 NORDIL patients, 87 had serum sampled at baseline and developed CHD over 4.5 years, matched to 227 controls. Higher titers of IgM anti-MDA-LDL had a protective effect on adverse outcomes, with odds ratio 0.29 (0.11, 0.76; p=0.012; p=0.016 for trend). Therefore, the effect was explored at the lesional level in IBIS-3. 143 patients had blood samples and RF-IVUS measurements available, and NIRS was performed in 90 of these. At baseline, IgM anti-MDA-LDL levels had a strong independent inverse relationship with lesional necrotic core volume (p=0.027) and percentage of plaque occupied by necrotic core (p=0.011), as well as lipid core burden index (p=0.024) in the worst 4 mm segment.Interpretation: Our study supports the hypothesis that lower circulating levels of IgM anti-MDA-LDL are associated with clinical CHD development, and for the first time relates these findings to atherosclerotic plaque characteristics that are linked to vulnerability.
|
|
2. |
- Kobo, Ofer, et al.
(författare)
-
Impact of Multisite artery disease on Clinical Outcomes After Percutaneous Coronary Intervention : An Analysis from the e-Ultimaster Registry
- 2023
-
Ingår i: European Heart Journal - Quality of Care and Clinical Outcomes. - : Oxford University Press. - 2058-5225 .- 2058-1742. ; 9:4, s. 417-426
-
Tidskriftsartikel (refereegranskat)abstract
- BACKGROUND: Multisite artery disease is considered a 'malignant' type of atherosclerotic disease associated with an increased cardiovascular risk, but the impact of multisite artery disease on clinical outcomes after percutaneous coronary intervention (PCI) is unknown.METHODS: Patients enrolled in the large, prospective e-Ultimaster study were grouped into 1) those without known prior vascular disease; 2) those with known single-territory vascular disease 3) those with known 2-3 territories (i.e, coronary, cerebrovascular, or peripheral) vascular disease (multisite artery disease). The primary outcome was coronary target lesion failure (TLF) defined as the composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target lesion revascularization at 1-year. Inverse propensity score weighted (IPSW) analysis was performed to address differences in baseline patient and lesion characteristics.RESULTS: Of the 37,198 patients included in the study, 62.3% had no prior known vascular disease, 32.6% had single-territory vascular disease, and 5.1% multisite artery disease. Patients with known vascular disease were older and were more likely to be men and to have more co-morbidities. After IPSW, the TLF rate incrementally increased with the number of diseased vascular beds (3.16%, 4.44% and 6.42% for no, single- and multisite artery disease, p<0.01 for all comparisons). This was also true for all cause death (2.22%, 3.28% and 5.29%, p<0.01 for all comparisons) and cardiac mortality (1.26%, 1.91% and 3.62%, p≤0.01 for all comparisons).CONCLUSIONS: Patients with previously known vascular disease experienced an increased risk for adverse cardiovascular events and mortality post percutaneous coronary intervention. This risk is highest among patients with multisite artery disease.
|
|
3. |
- Vlieger, Selina, et al.
(författare)
-
One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent : a propensity-matched analysis of two international all-comers registries
- 2021
-
Ingår i: Coronary Artery Disease. - : Lippincott Williams & Wilkins. - 0954-6928 .- 1473-5830. ; 32:5, s. 391-396
-
Tidskriftsartikel (refereegranskat)abstract
- OBJECTIVES: Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice.METHODS: A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events.RESULTS: The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43).CONCLUSIONS: These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES.
|
|