SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Ohkubo Chikahiro) "

Search: WFRF:(Ohkubo Chikahiro)

  • Result 1-3 of 3
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Kokubo, Yuji, et al. (author)
  • Clinical Marginal and Internal Gaps of In-Ceram Crowns Fabricated Using the GN-I System
  • 2005
  • In: Journal of Oral Rehabilitation. - : Wiley. - 1365-2842 .- 0305-182X. ; 32:10, s. 753-758
  • Journal article (other academic/artistic)abstract
    • The marginal and internal gaps of ceramic crowns with alumina copings fabricated using a computer-aided design, computer-aided manufacturing system, were evaluated in vivo using silicone materials. Black and white silicone materials were used to record the marginal and internal gaps of 82 In-Ceram crowns before final cementation. The silicone materials were sectioned bucco-lingually and mesio-distally and viewed under a microscope to measure the thickness of the white silicone layer. Sixteen reference points were measured on each specimen. The mean marginal gaps were compared among the anterior, premolar and molar teeth, and the mean gaps at the reference points within the groups were compared by analysis of variance and the Dunnett T3 test. The mean marginal gap was 66.8 mum. There were no differences in marginal gaps among the three groups. In all the groups, the marginal gaps were the smallest, whereas the occlusal gaps were the largest. The mean marginal gaps of the In-Ceram crowns with the alumina copings fabricated using the GN-I system were within the range of clinically acceptable values.
  •  
2.
  • Kokubo, Yuji, et al. (author)
  • Clinical Marginal and Internal Gaps of Procera AllCeram Crowns
  • 2005
  • In: Journal of Oral Rehabilitation. - : Wiley. - 1365-2842 .- 0305-182X. ; 32:7, s. 526-530
  • Journal article (other academic/artistic)abstract
    • This study evaluated the marginal and internal gaps of Procera AllCeram crowns in vivo using silicone materials. Ninety Procera AllCeram crowns were evaluated before final cementation. White and black silicone materials were used to record the marginal and internal fit; then the crowns were sectioned bucco-lingually and mesio-distally to measure the thickness of the silicone layer using a microscope. Sixteen reference points were measured on each specimen. Mean marginal gaps among anterior, premolar and molar teeth, and mean gaps at the reference points within the groups were compared by analysis of variance and Dunnett T3 test. The mean values at the margins were the smallest in all tooth groups, whereas those at the rounded slope of the chamfer were the largest. There were significant differences (P < 0.001) in the mean gaps at the four reference points (margin, rounded slope of the chamfer, axial wall and occlusal surface) in each group, except for the molar teeth. The mean marginal gaps of the Procera AllCeram crowns were within the range of clinical acceptance.
  •  
3.
  • Kokubo, Yuji, et al. (author)
  • Clinical marginal gap of porcelain fused to electro-formed gold coping crowns
  • 2006
  • In: European Journal of Prosthodontics and Restorative Dentistry. - 0965-7452. ; 14:2, s. 85-89
  • Journal article (peer-reviewed)abstract
    • This study evaluated the marginal and internal gaps of Auro Galvano Crowns (AGC) in vivo. One hundred AGC crowns were examined using white and black silicone materials; the thickness of the silicone layer was measured at 16 reference points using a microscope. The mean marginal gaps among anterior, premolar and molar teeth, and the mean gaps within the groups were compared by analysis of variance and Dunnett T3 test. The results showed that at the margins, there were no significant differences among the four measuring points within each group, and there were no significant differences in the mean marginal gaps among the three groups. The mean marginal gaps in all groups were within the limits of clinical acceptability.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-3 of 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view