SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Okamoto Roberta) "

Sökning: WFRF:(Okamoto Roberta)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Klionsky, Daniel J., et al. (författare)
  • Guidelines for the use and interpretation of assays for monitoring autophagy
  • 2012
  • Ingår i: Autophagy. - : Informa UK Limited. - 1554-8635 .- 1554-8627. ; 8:4, s. 445-544
  • Forskningsöversikt (refereegranskat)abstract
    • In 2008 we published the first set of guidelines for standardizing research in autophagy. Since then, research on this topic has continued to accelerate, and many new scientists have entered the field. Our knowledge base and relevant new technologies have also been expanding. Accordingly, it is important to update these guidelines for monitoring autophagy in different organisms. Various reviews have described the range of assays that have been used for this purpose. Nevertheless, there continues to be confusion regarding acceptable methods to measure autophagy, especially in multicellular eukaryotes. A key point that needs to be emphasized is that there is a difference between measurements that monitor the numbers or volume of autophagic elements (e.g., autophagosomes or autolysosomes) at any stage of the autophagic process vs. those that measure flux through the autophagy pathway (i.e., the complete process); thus, a block in macroautophagy that results in autophagosome accumulation needs to be differentiated from stimuli that result in increased autophagic activity, defined as increased autophagy induction coupled with increased delivery to, and degradation within, lysosomes (in most higher eukaryotes and some protists such as Dictyostelium) or the vacuole (in plants and fungi). In other words, it is especially important that investigators new to the field understand that the appearance of more autophagosomes does not necessarily equate with more autophagy. In fact, in many cases, autophagosomes accumulate because of a block in trafficking to lysosomes without a concomitant change in autophagosome biogenesis, whereas an increase in autolysosomes may reflect a reduction in degradative activity. Here, we present a set of guidelines for the selection and interpretation of methods for use by investigators who aim to examine macroautophagy and related processes, as well as for reviewers who need to provide realistic and reasonable critiques of papers that are focused on these processes. These guidelines are not meant to be a formulaic set of rules, because the appropriate assays depend in part on the question being asked and the system being used. In addition, we emphasize that no individual assay is guaranteed to be the most appropriate one in every situation, and we strongly recommend the use of multiple assays to monitor autophagy. In these guidelines, we consider these various methods of assessing autophagy and what information can, or cannot, be obtained from them. Finally, by discussing the merits and limits of particular autophagy assays, we hope to encourage technical innovation in the field.
  •  
2.
  •  
3.
  • de Oliveira Neto, Patricio José, et al. (författare)
  • Tomographic, histological, and immunohistochemical evidences on the use of N-butyl-2-cyanoacrilate for onlay graft fixation in rabbits
  • 2012
  • Ingår i: Clinical Implant Dentistry and Related Research. - : Wiley. - 1523-0899 .- 1708-8208. ; 14:6, s. 861-871
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The bone tissue responses to Cyanoacrylate have been described in the literature, but none used N-butyl-2-cyanoacrilate (NB-Cn) for bone graft fixation.Purpose: The aims of the study were: (a) to analyze the bone grafts volume maintenance fixed either with NB-Cn or titanium screw; (b) to assess the incorporation of onlay grafts on perforated recipient bed; and (c) the differences of expression level of tartrate-resistant acid phosphatase (TRAP) protein involved in bone resorption.Materials and Methods: Eighteen New Zealand White rabbits were submitted to calvaria onlay grafting on both sides of the mandible. On one side, the graft was fixed with NB-Cn, while on the other hand the bone graft was secured with an osteosynthesis screw. The computed tomography (CT) was performed just after surgery and at animals sacrifice, after 1 (n = 9) and 6 weeks (n = 9), in order to estimate the bone grafts volume along the experiments. Histological sections of the grafted areas were prepared to evaluate the healing of bone grafts and to assess the expression of TRAP protein.Results: The CT scan showed better volume maintenance of bone grafts fixed with NB-Cn (p ≤ 0.05) compared with those fixed with screws, in both experimental times (analysis of variance). The immunohistochemical evaluation showed that the TRAP expression in a 6-week period was significantly higher compared with the 1-week period, without showing significant difference between the groups (Wilcoxon and Mann-Whitney). Histological analysis revealed that the NB-Cn caused periosteum damage, but provided bone graft stabilization and incorporation similar to the control group.Conclusion: The perforation provided by screw insertion into the graft during fixation may have triggered early revascularization and remodeling to render increased volume loss compared with the experimental group. These results indicate that the NB-Cn possesses equivalent properties to titanium screw to be used as bone fixation material in osteosynthesis.
  •  
4.
  • Gomes-Ferreira, Pedro Henrique Silva, et al. (författare)
  • PTH 1-34-functionalized bioactive glass improves peri-implant bone repair in orchiectomized rats: Microscale and ultrastructural evaluation
  • 2022
  • Ingår i: Biomaterials Advances. - : Elsevier BV. - 2772-9508. ; 134
  • Tidskriftsartikel (refereegranskat)abstract
    • The objective of this work was to investigate the use of Biogran® functionalized with parathyroid hormone (PTH) 1–34 by sonochemistry for the local delivery of this anabolic agent to the implant site. The effects of Biogran® and topical administration of PTH 1–34 on peri-implant bone regeneration were evaluated from the microscale to ultrastructural levels in healthy (SHAM) and orchiectomized (ORQ). While some animals only received a titanium implant in their tibial metaphyses (CLOT group), in others the peri-implant defect was first filled with Biogran® either without or with PTH 1–34 functionalization (BG and BGPTH groups, respectively) prior to implant installation. Osseointegration was characterized from a biomechanical perspective by measuring the removal torque with the counter-torque technique. Micro-CT was used to evaluate the percentage of bone volume, trabecular thickness, number and separation, and bone-implant contact (BIC). Dynamics of new bone formation were assessed by measuring fluorochrome area, daily mineral apposition rate, and neoformed bone area using confocal laser microscopy. RT-PCR was performed to evaluate ALP and osteocalcin expression. The interface between newly formed bone and Biogran® was examined using scanning electron microscopy (SEM) and scanning transmission electron microscopy (STEM) at the micro-and nanoscale, respectively, while elemental analyses were completed in SEM with energy-dispersive X-ray spectroscopy (EDS). STEM imaging demonstrated the intimate attachment of bone to Biogran® (nanoscale level). Overall, the results suggest that the effectiveness of the topical administration of PTH 1–34 at the implant site seems enhanced in osteoporotic bone, promoting peri-implant bone regeneration to comparable levels in healthy conditions.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy