SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Olivecrona Henrik) "

Sökning: WFRF:(Olivecrona Henrik)

  • Resultat 1-10 av 78
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Alcala, Yvonne, et al. (författare)
  • Qualifying CT for wrist arthroplasty : Extending techniques for total hip arthroplasty to total wrist arthroplasty
  • 2005
  • Ingår i: Medical Imaging 2005. - : SPIE - The International Sooceity for Optical Engineeering. - 0819457213 ; , s. 1155-1164
  • Konferensbidrag (refereegranskat)abstract
    • The purpose of this study was to extend previous work to detect migration of total wrist arthroplasty non-invasively, and with greater accuracy. Two human cadaverous arms, each with a cemented total wrist implant, were used in this study. In one of the arms, I mm tantalum balls were implanted, six in the carpal bones and five in the radius. Five CT scans of each arm were acquired, changing the position of the arm each time to mimic different positions patients might take on repeated examinations. Registration of CT volume data sets was performed using an extensively validated, 3D semi-automatic volume fusion tool in which co-homologous point pairs (landmarks) are chosen on each volume to be registered. Three sets of ten cases each were obtained by placing landmarks on 1) bone only (using only arm one), 2) tantalum implants only, and 3) bone and tantalum implants (both using only arm two). The accuracy of the match was assessed visually in 2D and 3D, and numerically by calculating the distance difference between the actual position of the transformed landmarks and their ideal position (i.e., the reference landmark positions). All cases were matched visually within one width of cortical bone and numerically within one half CT voxel (0.32 mm, p = 0.05). This method matched only the bone/arm and not the prosthetic component per se, thus making it possible to detect prosthetic movement and wear. This method was clinically used for one patient with pain. Loosening of the carpal prosthetic component was accurately detected and this was confirmed at surgery.
  •  
2.
  • Goldvasser, Dov, et al. (författare)
  • A New Technique for Measuring Wear in Total Hip Arthroplasty Using Computed Tomography
  • 2012
  • Ingår i: The Journal of Arthroplasty. - : Elsevier. - 0883-5403 .- 1532-8406. ; 27:9, s. 1636-1640
  • Tidskriftsartikel (refereegranskat)abstract
    • Accurately estimating polyethylene wear in 3 dimensions, without the need for additional procedures or equipment, is of significant interest. We investigated the use of a high-resolution clinical computed tomographic (CT) scanner to estimate femoral head displacement relative to the cup as an indirect method of estimating polyethylene wear. A hip phantom was used to simulate the 3-dimensional displacement of a femoral head. The phantom was imaged in a high-resolution CT scanner. The mean difference between the true phantom displacement as positioned by micrometers and the calculated displacement based on the CT images was as follows: for the x-axis, 0 mm (SD, 0.213; SE, 0.058); y-axis, 0.039 mm (SD, 0.035; SE, 0.026); and z-axis, 0.039 mm (SD, 0.051; SE, 0.020).
  •  
3.
  • Goldvasser, Dov, et al. (författare)
  • In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty
  • 2014
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 85:3, s. 271-275
  • Tidskriftsartikel (refereegranskat)abstract
    • Background - Determination of the amount of wear in a polyethylene liner following total hip arthroplasty (THA) is important for both the clinical care of individual patients and the development of new types of liners. Patients and methods - We measured in vivo wear of the polyethylene liner using computed tomography (CT) (obtained in the course of regular clinical care) and compared it to coordinate-measuring machine (CMM) readings. Also, changes in liner thickness of the same retrieved polyethylene liner were measured using a micrometer, and were compared to CT and CMM measurements. The distance between the centers of the acetabular cup and femoral head component was measured in 3D CT, using a semi-automatic analysis method. CMM readings were performed on each acetabular liner and data were analyzed using 3D computer-aided design software. Micrometer readings compared the thickest and thinnest regions of the liner. We analyzed 10 THA CTs and retrievals that met minimal requirements for CT slice thickness and explanted cup condition. Results - For the 10 cups, the mean difference between the CT readings and the CMM readings was -0.09 (-0.38 to 0.20) mm. This difference was not statistically significant (p = 0.6). Between CT and micrometer, the mean difference was 0.11 (-0.33 to 0.55) mm. This difference was not statistically significant (p = 0.6). Interpretation - Our results show that CT imaging is ready to be used as a tool in clinical wear measurement of polyethylene liners used in THA.
  •  
4.
  • Jedenmalm, Anneli, et al. (författare)
  • A new approach for assessment of wear in metal-backed acetabular cups using computed tomography : a phantom study with retrievals
  • 2008
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 79:2, s. 218-224
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose Polyethylene wear is an important cause of aseptic loosening in hip arthroplasty. Detection of significant wear usually happens late on, since available diagnostic techniques are either not sensitive enough or too complicated and expensive for routine use. This study evaluates a new approach for measurement of linear wear of metal-backed acetabular cups using CT as the intended clinically feasible method. Material and methods 8 retrieved uncemented metal-backed acetabular cups were scanned twice ex vivo using CT. The linear penetration depth of the femoral head into the cup was measured in the CT volumes using dedicated software. Landmark points were placed on the CT images of cup and head, and also on a reference plane in order to calculate the wear vector magnitude and angle to one of the axes. A coordinate-measuring machine was used to test the accuracy of the proposed CT method. For this purpose, the head diameters were also measured by both methods. Results Accuracy of the CT method for linear wear measurements was 0.6 nm and wear vector angle was 27 degrees. No systematic difference was found between CT scans. Interpretation This study on explanted acetabular cups shows that CT is capable of reliable measurement of linear wear in acetabular cups at a clinically relevant level of accuracy. It was also possible to use the method for assessment of direction of wear.
  •  
5.
  • Lundblad, Henrik, et al. (författare)
  • Can Na18F PET/CT Be Used to Study Bone Remodeling in the Tibia When Patients Are Being Treated with a Taylor Spatial Frame?
  • 2014
  • Ingår i: Scientific World Journal. - : Hindawi Publishing Corporation. - 1537-744X .- 2356-6140. ; 2014, s. 1-9
  • Tidskriftsartikel (refereegranskat)abstract
    • Monitoring and quantifying bone remodeling are of interest, for example, in correction osteotomies, delayed fracture healing pseudarthrosis, bone lengthening, and other instances. Seven patients who had operations to attach an Ilizarov-derived Taylor Spatial Frame to the tibia gave informed consent. Each patient was examined by (NaF)-F-18 PET/CT twice, at approximately six weeks and three months after the operation. A validated software tool was used for the following processing steps. The first and second CT volumes were aligned in 3D and the respective PET volumes were aligned accordingly. In the first PET volume spherical volumes of interest (VOIs) were delineated for the crural fracture and normal bone and transferred to the second PET volume for SUVmax evaluation. This method potentially provides clinical insight into questions such as, when has the bone remodeling progressed well enough to safely remove the TSF? and when is intervention required, in a timelier manner than current methods? For example, in two patients who completed treatment, the SUVmax between the first and second PET/CT examination decreased by 42% and 13%, respectively. Further studies in a larger patient population are needed to verify these preliminary results by correlating regional (NaF)-F-18 PET measurements to clinical and radiological findings.
  •  
6.
  • Noz, Marilyn E., et al. (författare)
  • Clinical applications from head to toe using a semiautomatic 3D inter/intramodality fusion technique
  • 2003
  • Ingår i: BIOMEDICAL IMAGE REGISTRATION. - 3540203435 ; , s. 387-397
  • Konferensbidrag (refereegranskat)abstract
    • Automated image registration techniques, particularly between modalities which clearly display anatomy and especially within the head, have become commonplace. Meanwhile advances in molecular imaging and the need to perform registration in other areas of body has driven the development of non-rigid and semiautomatic 3D volume fusion methods. This paper will focus on this latter class of 3D volume registration methods for a variety of clinical applications.
  •  
7.
  • Olivecrona, Grim, et al. (författare)
  • Assessment of the sacroiliac joint with computed tomography motion analysis : a diagnostic study of 12 patients
  • 2024
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden. - 1745-3674 .- 1745-3682. ; 95, s. 20-24
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose - Pain in the sacroiliac joint may be caused by abnormal joint motion. Diagnosis is mainly based on clinical tests. The aims of this study were to examine whether low-dose computed tomography with provocation of the hip could detect sacroiliac joint motion , to study whether provocation of the hip results in greater sacroiliac joint motion in the ipsilateral than in the contralateral sacroiliac joint.Patients and methods - 12 patients with sacroiliac joint pain were examined with low-dose computed tomography scans of the sacroiliac joint, one with the hips in the neutral position, and one each in provocation with the left or the right hip in a figure-of-4 position. Accuracy was tested by comparing internal rotation of the sacrum with internal rotation in the sacroiliac joint. Motion in the sacroiliac joint was assessed by comparing the position of each of the ilia with the reference, the sacrum. Data is shown as mean with 95% confidence interval (CI).Results - We observed greater motion in the sacroiliac joint than internally in the sacrum, i.e., 0.57(degrees) (CI 0.43-0.71) vs. 0.20(degrees) (CI 0.11-0.28). The motion of the geometric center of the moving object for the sacroiliac joint was larger on the provoked side; mean difference 0.17 mm (CI 0.01-0.33), P = 0.04. Corresponding figures for rotation were mean difference 0.19(degrees) (CI 0.10-0.28), P < 0.001. Compared with the sacrum, the largest motion was seen at the anterior superior iliac spine; mean difference 0.38 mm (CI 0.10-0.66), P = 0.001.Conclusion - Provocation in the figure-of-4 position of the hip results in sacroiliac joint motion measurable with computed tomography motion analysis. Provocation of the hip induces larger motion on the ipsilateral than on the contralateral sacroiliac joint.
  •  
8.
  • Olivecrona, Gunilla, et al. (författare)
  • Mutation of conserved cysteines in the Ly6 domain of GPIHBP1 in familial chylomicronemia
  • 2010
  • Ingår i: Journal of Lipid Research. - New York : Rockefeller U.P.. - 0022-2275 .- 1539-7262. ; 51:6, s. 1535-1545
  • Tidskriftsartikel (refereegranskat)abstract
    • We investigated a family from northern Sweden in which three of four siblings have congenital chylomicronemia. Lipoprotein lipase (LPL) activity and mass in pre- and post-heparin plasma were low, and LPL release into plasma after heparin injection was delayed. LPL activity and mass in adipose tissue biopsies appeared normal. [35S]Methionine incorporation studies on adipose tissue showed that newly synthesized LPL was normal in size and normally glycosylated. Breast milk from the affected female subjects contained normal to elevated LPL mass and activity levels. The milk had a lower than normal milk lipid content, and the fatty acid composition was compatible with the milk lipids being derived from de novo lipogenesis, rather than from the plasma lipoproteins. Given the delayed release of LPL into the plasma after heparin, we suspected that the chylomicronemia might be caused by mutations in GPIHBP1. Indeed, all three affected siblings were compound heterozygotes for missense mutations involving highly conserved cysteines in the Ly6 domain of GPIHBP1 (C65S and C68G). The mutant GPIHBP1 proteins reached the surface of transfected CHO cells but were defective in their ability to bind LPL (as judged by both cell-based and cell-free LPL binding assays). Thus, the conserved cysteines in the Ly6 domain are crucial for GPIHBP1 function.
  •  
9.
  • Olivecrona, Henrik, et al. (författare)
  • A new computed tomography-based radiographic method to detect early loosening of total wrist implants
  • 2007
  • Ingår i: Acta Radiologica. - London, UK : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 48:9, s. 997-1003
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Diagnosis of loosening of total wrist implants is usually late using routine radiographs. Switching modality to computed tomography (CT) should aid in early diagnosis. Purpose: To propose and evaluate the accuracy of a new CT method for assessing loosening of the carpal component in total wrist arthroplasty. Material and Methods: A protocol encompassing volume registration of paired CT scans of patients with unexplained pain in a prosthetically replaced wrist (used in clinical routine) is presented. Scans are acquired as a dynamic examination under torsional load. Using volume registration, the carpal component of the prosthesis is brought into spatial alignment. After registration, prosthetic loosening is diagnosed by a shift in position of the bones relative to the prosthesis. This study is a preclinical validation of this method using a human cadaverous arm with a cemented total wrist implant and tantalum markers. Seven CT scans of the arm were acquired. The scans were combined into 21 pairs of CT volumes. The carpal component was registered in each scan pair, and the residual mismatch of the surrounding tantalum markers and bone was analyzed both visually and numerically. Results: The detection limit for prosthetic movement was less than 1 mm. Conclusion: The results of this study demonstrate that CT volume registration holds promise to improve detection of movement of the carpal component at an earlier stage than is obtainable with plain radiography.
  •  
10.
  • Olivecrona, Henrik, et al. (författare)
  • A new CT method for measuring cup orientation after total hip arthroplasty : A study of 10 patients
  • 2004
  • Ingår i: Acta Orthopaedica Scandinavica. - : Medical Journals Sweden AB. - 0001-6470. ; 75:3, s. 252-260
  • Tidskriftsartikel (refereegranskat)abstract
    • Background It is difficult to assess the orientation of the acetabular component on routine radiographs. We present a method for determining the spatial orientation of the acetabular component after total hip arthroplasty (THA) using computed tomography. Patients and methods Two CT-scans, 10 min apart, were obtained from each of 10 patients after THA. Using locally developed software, two independent examiners measured the orientation of the acetabular component in relation to the pelvis. The measurements were repeated after one week. To be independent of the patient position during scanning, the method involved two steps. Firstly, a 3D volumetric image of the pelvis was brought into a standard pelvic orientation, then the orientation of the acetabular component was measured. The orientation of the acetabular component was expressed as operative anteversion and inclination relative to an internal pelvic reference coordinate system. To evaluate precision, we compared measurements across pairs of CT volumes between observers and trials. Results Mean absolute interobserver angle error was 2.3degrees for anteversion (range 0-6.6degrees), and 1.1degrees for inclination (range 0-4.6degrees). For interobserver measurements, the precision, defined as one standard deviation, was 2.9degrees for anteversion, and 1.5degrees for inclination. A Student's West showed that the overall differences between the examiners, trials, and cases were not significant. Data were normally distributed and were not dependent on examiner or trial. Interpretation We conclude that the implant angles of the acetabular component in relation to the pelvis could be detected repeatedly using CT, independently of patient positioning.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 78
Typ av publikation
tidskriftsartikel (67)
konferensbidrag (6)
annan publikation (3)
doktorsavhandling (1)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (69)
övrigt vetenskapligt/konstnärligt (9)
Författare/redaktör
Olivecrona, Henrik (45)
Noz, Marilyn E. (33)
Zeleznik, Michael P. (28)
Maguire Jr., Gerald ... (23)
Olivecrona, Göran (20)
Götberg, Matthias (12)
visa fler...
Erlinge, David (11)
Engblom, Henrik (11)
Olivecrona, Lotta (11)
Harnek, Jan (11)
Arheden, Håkan (9)
Ugander, Martin (8)
Wagner, Henrik (7)
Carlsson, Marcus (6)
Clemmensen, Peter (6)
Stark, Andreas (6)
Koul, Sasha (5)
Maguire, Gerald Q. J ... (5)
Lassen, Jens Flenste ... (5)
Olivecrona, Gunilla (5)
Stankovic, Goran (5)
Brodén, Cyrus (5)
Wretenberg, Per, 196 ... (4)
Jedenmalm, Anneli (4)
Rundgren, Malin (4)
Hardig, Bjarne Madse ... (4)
Sandberg, Olof (3)
Wallentin, Lars (3)
James, Stefan (3)
Heiberg, Einar (3)
Aspelin, Peter (3)
Cairns, John A. (3)
Jonson, T (3)
Lundqvist, Eva, 1985 ... (3)
vanderPals, Jesper (3)
Olivecrona, Göran K. (3)
Sagerfors, Marcus, M ... (3)
Gao, Peggy (3)
Jensen, Ulf (3)
Emery, Roger (3)
Olivecrona, Goran K. (3)
Crafoord, Joakim (3)
Noc, Marko (3)
Holzer, Michael (3)
Zijlstra, Felix (3)
Kedev, Sasko (3)
Metzler, Bernhard (3)
Maguire Jr., Gerald ... (3)
Lang, Irene (3)
Botker, Hans Erik (3)
visa färre...
Lärosäte
Karolinska Institutet (38)
Kungliga Tekniska Högskolan (33)
Lunds universitet (27)
Uppsala universitet (13)
Umeå universitet (8)
Göteborgs universitet (6)
visa fler...
Örebro universitet (6)
Chalmers tekniska högskola (2)
Mittuniversitetet (1)
Högskolan i Borås (1)
visa färre...
Språk
Engelska (78)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (70)
Teknik (3)
Naturvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy