SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Oster C.) "

Sökning: WFRF:(Oster C.)

  • Resultat 1-10 av 11
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • 2019
  • Tidskriftsartikel (refereegranskat)
  •  
2.
  • Wang, J., et al. (författare)
  • Final report of the CCQM-K145 : Toxic and essential elements in bovine liver
  • 2020
  • Ingår i: Metrologia. - : IOP Publishing Ltd. - 0026-1394 .- 1681-7575. ; 57:1 A
  • Tidskriftsartikel (refereegranskat)abstract
    • Liver plays a major role in metabolism and acts as a source of energy for the body by storing glycogen. With the growing interest and investigation in the biological effects in recent years, it is important and necessary to develop accurate and comparable analytical methods for elements in bio-samples. It has, however, been 10 years since the tissue sample (bovine liver) of CCQM-K49 key comparison. The purpose of CCQM-K145 is to ensure the comparable and traceable measurement results for essential and toxic elements such as P, S, Zn, Mn, Ni, Mo, Sr, Cr, Co, Pb, As and Hg in bovine liver among NMIs and other designated measurement bodies worldwide. The comparison was agreed by IAWG as 6th IAWG Benchmarking Exercise with Zn and Ni as exemplary elements at the meeting in Korea in the early October 2016. The results of CCQM-K145 are expected to cover the measurement capability and support CMCs claiming for inorganic elements in the similar biological tissue materials and food samples. 30 NMIs and DIs registered in CCQM-K145. With respect to the methodology, a variety of techniques such as IDMS, ICP-OES, ICP-MS(non-ID), AAS and NAA were adopted by the participants. For Zn, Ni, Sr, Pb and Hg measurements, most participants chose ID-ICP-MS method, which showed the better performance in terms of consistency and reliability of the measurement results. In aspect of the traceability for the measurement results in CCQM-K145, most participants used their own (in house) CRMs or other NMI's CRMs to guarantee trace to SI unit. Most participants used similar matrix CRMs for quality control or method validation. Base on different statistic way to calculate the reference mass fraction values and associated uncertainties for each measurand, removal of the suspected extreme values, and discussion at the IAWG meetings, the median values are proposed as the KCRV for Zn, Ni, Mn, Mo, Cr, Pb and Hg; the arithmetic mean values are proposed as the KCRV for P, S, Sr, Co and As. In general, the performances of the majority of CCQM-K145 participants are very good, illustrating their measurement capabilities for Zn, Ni, P, S, Mn, Mo, Sr, Cr, As, Co, Pb and Hg in a complex biological tissue matrix. Bovine liver contains many kinds of nutrients and microelements, it can be regarded as a typical representative material of biological tissue and food. In CCQM-K145, the analytes involved alkali metals and transition elements, metalloids/semi-metals and non metals with a range of mass fraction from mg/g to μg/kg. CCQM-K145 also tested the ability of NMIs/DIs to determine elements that were easy to be lost and polluted, and interfered significantly. The chemical pretreatment methods of samples used in the comparison is suitable for general food and biological matrix samples. A variety of measurement methods used in the comparison represent the main instrumental technology for elemental analysis. Therefore, for supporting CMC claim, CCQM-K145 is readily applicable to measurement of more elements in a wide range of biological materials (including liquids and solids) and meat products. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
  •  
3.
  •  
4.
  • Saxholm, S., et al. (författare)
  • Development of measurement and calibration techniques for dynamic pressures and temperatures (DynPT) : Background and objectives of the 17IND07 DynPT project in the European Metrology Programme for Innovation and Research (EMPIR)
  • 2018
  • Ingår i: Journal of Physics. - : Institute of Physics Publishing.
  • Konferensbidrag (refereegranskat)abstract
    • This project has five specific objectives: To provide traceability for dynamic pressure and temperature through development of measurement standards and validated calibration procedures; To quantify the effects of influencing quantities on the response of dynamic pressure and temperature sensors, in order to determine the appropriate calibration procedures and measurement uncertainties for industrial measurements; To develop new measurement methods and sensors for measuring dynamic pressure and temperature in demanding industrial applications, and to demonstrate the improved accuracy and reliability obtained with those; To validate all of the methods and sensors developed in this project through demonstrations in selected industrial applications; and To ensure by close engagement with industry, that the developed calibration and measurement techniques and technology are adopted by them. The challenge is that in many industrial applications pressure and temperature measurements are performed under dynamically changing conditions. The aim of this project is to improve the accuracy and reliability of pressure and temperature measurements in these challenging conditions. A European joint research project named Development of measurement and calibration techniques for dynamic pressures and temperatures (shortname DynPT) started in the summer 2018.
  •  
5.
  • Elsasser, M., et al. (författare)
  • Organic molecular markers and signature from wood combustion particles in winter ambient aerosols: aerosol mass spectrometer (AMS) and high time-resolved GC-MS measurements in Augsburg, Germany
  • 2012
  • Ingår i: Atmospheric Chemistry and Physics. - : Copernicus GmbH. - 1680-7316 .- 1680-7324. ; 12:14, s. 6113-6128
  • Tidskriftsartikel (refereegranskat)abstract
    • The impact of wood combustion on ambient aerosols was investigated in Augsburg, Germany during a winter measurement campaign of a six-week period. Special attention was paid to the high time resolution observations of wood combustion with different mass spectrometric methods. Here we present and compare the results from an Aerodyne aerosol mass spectrometer (AMS) and gas chromatographic - mass spectrometric (GC-MS) analysed PM1 filters on an hourly basis. This includes source apportionment of the AMS derived organic matter (OM) using positive matrix factorisation (PMF) and analysis of levoglucosan as wood combustion marker, respectively. During the measurement period nitrate and OM mass are the main contributors to the defined submicron particle mass of AMS and Aethalometer with 28% and 35%, respectively. Wood combustion organic aerosol (WCOA) contributes to OM with 23% on average and 27% in the evening and night time. Conclusively, wood combustion has a strong influence on the organic matter and overall aerosol composition. Levoglucosan accounts for 14% of WCOA mass with a higher percentage in comparison to other studies. The ratio between the mass of levoglucosan and organic carbon amounts to 0.06. This study is unique in that it provides a one-hour time resolution comparison between the wood combustion results of the AMS and the GC-MS analysed filter method at a PM1 particle size range. The comparison of the concentration variation with time of the PMF WCOA factor, levoglucosan estimated by the AMS data and the levoglucosan measured by GC-MS is highly correlated (R-2 = 0.84), and a detailed discussion on the contributors to the wood combustion marker ion at mass-to-charge ratio 60 is given. At the end, both estimations, the WCOA factor and the levoglucosan concentration estimated by AMS data, allow to observe the variation with time of wood combustion emissions (gradient correlation with GC-MS levoglucosan of R-2 = 0.84). In the case of WCOA, it provides the estimated magnitude of wood combustion emission. Quantitative estimation of the levoglucosan concentration from the AMS data is problematic due to its overestimation in comparison to the levoglucosan measured by the GC-MS.
  •  
6.
  • Halling, A., et al. (författare)
  • Aluminum concentration in deciduous teeth is dependent on tooth type and dental status
  • 2001
  • Ingår i: Acta Odontologica Scandinavica. - : Informa UK Limited. - 0001-6357 .- 1502-3850. ; 59:6, s. 356-360
  • Tidskriftsartikel (refereegranskat)abstract
    • Aluminum (Al) concentration was assessed in deciduous teeth in relation to sex, year of birth, tooth type, and the presence of caries and roots. Three hundred and twenty-three deciduous teeth from children born during the period 1952-93 in a county in southeast Sweden were sampled, and the Al content determined by graphite furnace atomic absorption spectrophotometry. The arithmetic mean of the Al concentration was 0.58 ± 0.64 ppm dry weight mean ± standard deviation, and differed significantly between incisors (1.05 ± 1.04 ppm) and canines 0.48 ± 0.50 ppm and between incisors and molars (0.53 ± 0.55 ppm). A significant difference was found between teeth with and without caries. No significant differences were found between sexes. The Al concentration correlated significantly with tooth weight for incisors (r = -0.47) and canines (r = -0.45) but not for molars (r = 0.03). No significant change in Al concentration was found over time. Caries-free deciduous molars are suggested as the most useful teeth for biological monitoring of aluminum.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  • Oster, S K, et al. (författare)
  • Myc is an essential negative regulator of platelet-derived growth factor beta receptor expression.
  • 2000
  • Ingår i: Molecular and cellular biology. - 0270-7306. ; 20:18, s. 6768-78
  • Tidskriftsartikel (refereegranskat)abstract
    • Platelet-derived growth factor BB (PDGF BB) is a potent mitogen for fibroblasts as well as many other cell types. Interaction of PDGF BB with the PDGF beta receptor (PDGF-betaR) activates numerous signaling pathways and leads to a decrease in receptor expression on the cell surface. PDGF-betaR downregulation is effected at two levels, the immediate internalization of ligand-receptor complexes and the reduction in pdgf-betar mRNA expression. Our studies show that pdgf-betar mRNA suppression is regulated by the c-myc proto-oncogene. Both constitutive and inducible ectopic Myc protein can suppress pdgf-betar mRNA and protein. Suppression of pdgf-betar mRNA in response to Myc is specific, since expression of the related receptor pdgf-alphar is not affected. We further show that Myc suppresses pdgf-betar mRNA expression by a mechanism which is distinguishable from Myc autosuppression. Analysis of c-Myc-null fibroblasts demonstrates that Myc is required for the repression of pdgf-betar mRNA expression in quiescent fibroblasts following mitogen stimulation. In addition, it is evident that the Myc-mediated repression of pdgf-betar mRNA levels plays an important role in the regulation of basal pdgf-betar expression in proliferating cells. Thus, our studies suggest an essential role for Myc in a negative-feedback loop regulating the expression of the PDGF-betaR.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy