SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ostrowski Marek) "

Sökning: WFRF:(Ostrowski Marek)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abelev, Betty, et al. (författare)
  • Long-range angular correlations on the near and away side in p-Pb collisions at root S-NN=5.02 TeV
  • 2013
  • Ingår i: Physics Letters. Section B: Nuclear, Elementary Particle and High-Energy Physics. - : Elsevier BV. - 0370-2693. ; 719:1-3, s. 29-41
  • Tidskriftsartikel (refereegranskat)abstract
    • Angular correlations between charged trigger and associated particles are measured by the ALICE detector in p-Pb collisions at a nucleon-nucleon centre-of-mass energy of 5.02 TeV for transverse momentum ranges within 0.5 < P-T,P-assoc < P-T,P-trig < 4 GeV/c. The correlations are measured over two units of pseudorapidity and full azimuthal angle in different intervals of event multiplicity, and expressed as associated yield per trigger particle. Two long-range ridge-like structures, one on the near side and one on the away side, are observed when the per-trigger yield obtained in low-multiplicity events is subtracted from the one in high-multiplicity events. The excess on the near-side is qualitatively similar to that recently reported by the CMS Collaboration, while the excess on the away-side is reported for the first time. The two-ridge structure projected onto azimuthal angle is quantified with the second and third Fourier coefficients as well as by near-side and away-side yields and widths. The yields on the near side and on the away side are equal within the uncertainties for all studied event multiplicity and p(T) bins, and the widths show no significant evolution with event multiplicity or p(T). These findings suggest that the near-side ridge is accompanied by an essentially identical away-side ridge. (c) 2013 CERN. Published by Elsevier B.V. All rights reserved.
  •  
2.
  • Abelev, Betty, et al. (författare)
  • Measurement of prompt J/psi and beauty hadron production cross sections at mid-rapidity in pp collisions at root s=7 TeV
  • 2012
  • Ingår i: Journal of High Energy Physics. - 1029-8479. ; :11
  • Tidskriftsartikel (refereegranskat)abstract
    • The ALICE experiment at the LHC has studied J/psi production at mid-rapidity in pp collisions at root s = 7 TeV through its electron pair decay on a data sample corresponding to an integrated luminosity L-int = 5.6 nb(-1). The fraction of J/psi from the decay of long-lived beauty hadrons was determined for J/psi candidates with transverse momentum p(t) > 1,3 GeV/c and rapidity vertical bar y vertical bar < 0.9. The cross section for prompt J/psi mesons, i.e. directly produced J/psi and prompt decays of heavier charmonium states such as the psi(2S) and chi(c) resonances, is sigma(prompt J/psi) (p(t) > 1.3 GeV/c, vertical bar y vertical bar < 0.9) = 8.3 +/- 0.8(stat.) +/- 1.1 (syst.)(-1.4)(+1.5) (syst. pol.) mu b. The cross section for the production of b-hadrons decaying to J/psi with p(t) > 1.3 GeV/c and vertical bar y vertical bar < 0.9 is a sigma(J/psi <- hB) (p(t) > 1.3 GeV/c, vertical bar y vertical bar < 0.9) = 1.46 +/- 0.38 (stat.)(-0.32)(+0.26) (syst.) mu b. The results are compared to QCD model predictions. The shape of the p(t) and y distributions of b-quarks predicted by perturbative QCD model calculations are used to extrapolate the measured cross section to derive the b (b) over bar pair total cross section and d sigma/dy at mid-rapidity.
  •  
3.
  • Abelev, Betty, et al. (författare)
  • Underlying Event measurements in pp collisions at root s=0.9 and 7 TeV with the ALICE experiment at the LHC
  • 2012
  • Ingår i: Journal of High Energy Physics. - 1029-8479. ; :7
  • Tidskriftsartikel (refereegranskat)abstract
    • We present measurements of Underlying Event observables in pp collisions at root s = 0 : 9 and 7 TeV. The analysis is performed as a function of the highest charged-particle transverse momentum p(T),L-T in the event. Different regions are defined with respect to the azimuthal direction of the leading (highest transverse momentum) track: Toward, Transverse and Away. The Toward and Away regions collect the fragmentation products of the hardest partonic interaction. The Transverse region is expected to be most sensitive to the Underlying Event activity. The study is performed with charged particles above three different p(T) thresholds: 0.15, 0.5 and 1.0 GeV/c. In the Transverse region we observe an increase in the multiplicity of a factor 2-3 between the lower and higher collision energies, depending on the track p(T) threshold considered. Data are compared to PYTHIA 6.4, PYTHIA 8.1 and PHOJET. On average, all models considered underestimate the multiplicity and summed p(T) in the Transverse region by about 10-30%.
  •  
4.
  • Kraemer, Bernhard K., et al. (författare)
  • Tacrolimus-Based, Steroid-Free Regimens in Renal Transplantation : 3-Year Follow-Up of the ATLAS Trial
  • 2012
  • Ingår i: Transplantation. - 0041-1337 .- 1534-6080. ; 94:5, s. 492-498
  • Tidskriftsartikel (refereegranskat)abstract
    • Background. Long-term use of corticosteroids is associated with considerable morbidity, including cardiovascular and metabolic adverse effects. Methods. This study evaluated the long-term efficacy and safety of two steroid-free regimens compared with a triple immunosuppressive therapy in renal transplant recipients. This was a 3-year follow-up to a 6-month, open-label, randomized, multicenter study. Results. Data from 3 years were available for 421 (93.3%) of 451 patients in the original intent-to-treat population (143 tacrolimus/basiliximab [Tac/Bas], 139 tacrolimus/mycophenolate mofetil [Tac/MMF], and 139 tacrolimus/MMF/steroids [triple therapy]). In the time interval from 6 months to 3 years after transplantation, the incidence of biopsy-proven acute rejection was low and similar (Tac/Bas, 2.1%; Tac/MMF, 2.2%; triple therapy, 2.2%); Most rejection episodes occurred during the first 6 months of the study. Graft survival was high (Kaplan-Meier estimates: 92.7%, 92.5%, and 92.5%), as was patient survival (93.1%, 96.4%, and 97.0%). There were 10 graft losses (n=2, 4, and 4) and 12 patient deaths (n=5, 2, and 5). Renal function was well preserved throughout the study and similar between groups. There was a trend toward improved cardiovascular risk factors in the Tac/Bas group, including reduced total and low-density lipoprotein cholesterol and lower new-onset insulin use. There were no between-group differences in the incidence or type of adverse events. Conclusion. Higher rates of acute rejection early in treatment were seen with the steroid-free regimens, but this did not translate into poorer long-term outcomes, such as graft and patient survival and renal function. A trend for a more favorable cardiovascular risk profile was observed for steroid-free immunosuppression with Tac/Bas.
  •  
5.
  • Krämer, Bernhard K., et al. (författare)
  • Tacrolimus combined with two different corticosteroid-free regimens compared with a standard triple regimen in renal transplantation : one year observational results
  • 2010
  • Ingår i: Clinical Transplantation. - : Wiley. - 0902-0063 .- 1399-0012. ; 24:1, s. E1-E9
  • Tidskriftsartikel (refereegranskat)abstract
    • Side effects of steroid use have led to efforts to minimize their use in transplantation. Two corticosteroid-free regimens were compared with a triple immunosuppressive therapy. Data from the original intent-to-treat (ITT) population (153 tacrolimus/basiliximab [Tac/Bas], 151 tacrolimus/MMF [Tac/MMF], and 147 tacrolimus/MMF/steroids [control]) were analyzed in a 12-month follow-up. Percentage of graft survival were 92.8%, 95.4%, and 95.9% (KM estimates 89.9%, 95.3%, 95.9%), percentage of surviving patients were 98.7%, 98.0%, and 100% (KM estimates 95.9%, 92.8%, and 100%). During months 7-12, graft loss occurred in 3 Tac/Bas, 2 Tac/MMF, and zero control patients, patient deaths in 1 Tac/Bas, 2 Tac/MMF, and zero control, and biopsy-proven acute rejection episodes in 4 Tac/Bas, 3 Tac/MMF, and zero control. Mean serum creatinine at month 12 was 141.9 +/- 69.6 muM, 144.0 +/- 82.1 muM, and 134.5 +/- 71.2 muM (ns). New-onset insulin use in previously non-diabetic patients at month 12 was 1/138, 6/127, and 4/126. Patient and graft survival as well as renal function at 12 months were not different between patient groups, despite considerably higher rates of acute rejection occurring within the first six months after transplantation in both steroid-free patient groups. Tac/Bas therapy might offer benefits in terms of a trend for a more favorable cardiovascular risk profile.
  •  
6.
  • Szczesna-Chrzan, Anna, et al. (författare)
  • Systematic Studies on Liquid Sodium 4,5-dicyano-2-(trifluoromethyl)imidazolate (NaTDI)-Based Electrolytes and Its Impact on the Cycling Behaviour Against Wet Impregnated WI-NaNMC and Prussian White Cathodes
  • 2022
  • Ingår i: Advanced Materials Interfaces. - : John Wiley & Sons. - 2196-7350. ; 9:8
  • Tidskriftsartikel (refereegranskat)abstract
    • The article describes a research on new salts and cathode materials dedicated to sodium cells. Sodium technology is considered to be one of the most promising (for new battery generations) and has been very actively (re)-developed for more than a decade. The first part of this work is mainly focused on electrochemical studies of the low coordinating Huckel type salt (4,5-dicyano-2-(trifluoromethyl)imidazolate, NaTDI)-based electrolytes with and without solid electrolyte interface modified additives: fluoroethylene carbonate (FEC). In the second part electrolytes are tested in a half-cells with layered oxides. Sodium nickel-manganese-cobalt oxide (NaNMC) and WI-NaNMC-333 and WI-NaNMC-622 layered cathode materials are prepared by wet impregnation synthesis (WI) routine. Prussian White is obtained from University of Uppsala group to compare and initial electrochemical properties against electrolyte with NaTDI. Basic physicochemical properties of the obtained powders are also reported in the manuscript. The best properties are recorded for 0.75 m NaTDI in EC:DMC (1:1 v/v) with 3% FEC additive by its conductivity (11.52 mS cm(-1) for 20 degrees C). The same solution also shows promising results during electrochemical tests in half-cell geometry against WI-NaNMC-622 cathode (114.22 mAh g(-1) after 1 cycle C/20). NaPF6 salt is used as an electrolyte as a commercially available reference.
  •  
7.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy