SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Paczek B.) "

Sökning: WFRF:(Paczek B.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • De Baetselier, E, et al. (författare)
  • EUPRON: nurses' practice in interprofessional pharmaceutical care in Europe. A cross-sectional survey in 17 countries
  • 2020
  • Ingår i: BMJ open. - : BMJ. - 2044-6055. ; 10:6, s. e036269-
  • Tidskriftsartikel (refereegranskat)abstract
    • Safe pharmaceutical care (PC) requires an interprofessional team approach, involving physicians, nurses and pharmacists. Nurses’ roles however, are not always explicit and clear, complicating interprofessional collaboration. The aim of this study is to describe nurses’ practice and interprofessional collaboration in PC, from the viewpoint of nurses, physicians and pharmacists.DesignA cross-sectional survey.SettingThe study was conducted in 17 European countries, each with their own health systems.ParticipantsPharmacists, physicians and nurses with an active role in PC were surveyed.Main outcome measuresNurses’ involvement in PC, experiences of interprofessional collaboration and communication and views on nurses’ competences.ResultsA total of 4888 nurses, 974 physicians and 857 pharmacists from 17 European countries responded. Providing patient education and information (PEI), monitoring medicines adherence (MMA), monitoring adverse/therapeutic effects (ME) and prescribing medicines were considered integral to nursing practice by 78%, 73%, 69% and 15% of nurses, respectively. Most respondents were convinced that quality of PC would be improved by increasing nurses’ involvement in ME (95%), MMA (95%), PEI (91%) and prescribing (53%). Mean scores for the reported quality of collaboration between nurses and physicians, collaboration between nurses and pharmacists and interprofessional communication were respectively <7/10, ≤4/10, <6/10 for all four aspects of PC.ConclusionsME, MMA, PEI and prescribing are part of nurses’ activities, and most healthcare professionals felt their involvement should be extended. Collaboration between nurses and physicians on PC is limited and between nurses and pharmacists even more.
  •  
3.
  • Draxler, K., et al. (författare)
  • International comparison of current transformer calibration systems up to 10 kA at 50 Hz frequency
  • 2016
  • Ingår i: 2016 Conference on Precision Electromagnetic Measurements (CPEM 2016). - 9781467391344
  • Konferensbidrag (refereegranskat)abstract
    • Current transformers (CTs) are precision devices that scale high currents down to values that can be easily handled by measurement equipment. To support CT applications in revenue metering, a comparison on AC current transformer calibration systems was performed among 15 European national metrology institutes using a precision CT as the travelling device. The first comparison results for the transformation ratios (4, 5, 6, 8, 10) kA/5 A of the travelling CT at nominal burden of 5 VA and 15 VA indicate good agreement between the participating laboratories. The main differences are found for phase displacement, at least partly caused by the instability of the traveling standard.
  •  
4.
  • Draxler, K., et al. (författare)
  • Results of an International Comparison of Instrument Current Transformers up to 10 kA at 50 Hz Frequency
  • 2018
  • Ingår i: CPEM 2018 - Conference on Precision Electromagnetic Measurements. - 9781538609736
  • Konferensbidrag (refereegranskat)abstract
    • Traceability of the current ratio is crucial for the measurement of electrical energy in revenue metering. A comparison of the AC current ratio was therefore performed within EURAMET in the time period 2012-2016, using a precision CT as the traveling device. The Czech Metrology Institute (CMI) as coordinator processed the measurement results of the 15 European participating laboratories. The comparison of the results for transformer ratios of (4, 5, 6, 8, 10) kA 5 A at 15 VA burden and (4 and 10) kA 5 A ratios at 5 VA burden indicates good agreement between the participating laboratories. The main differences are found for phase displacement, at least in part due to instability of the traveling standard. .
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy