SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Papachristidis Alexandros) "

Sökning: WFRF:(Papachristidis Alexandros)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Almeida, Nuno, et al. (författare)
  • Left atrial volumetric assessment using a novel automated framework for 3D echocardiography: a multi-centre analysis
  • 2017
  • Ingår i: European Heart Journal Cardiovascular Imaging. - : OXFORD UNIV PRESS. - 2047-2404 .- 2047-2412. ; 18:9, s. 1008-1015
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims This study aims at validating a software tool for automated segmentation and quantification of the left atrium (LA) from 3D echocardiography. Methods and results The LA segmentation tool uses a dual-chamber model of the left side of the heart to automatically detect and track the atrio-ventricular plane and the LA endocardium in transthoracic 3D echocardiography. The tool was tested in a dataset of 121 ultrasound images from patients with several cardiovascular pathologies (in a multi-centre setting), and the resulting volumes were compared with those assessed manually by experts in a blinded analysis using conventional contouring. Bland-Altman analysis showed good agreement between the automated method and the manual references, with differences (mean +/- 1.96 SD) of 0.5 +/- 5.7 mL for LA minimum volume and -1.6 +/- 9.7 mL for LA maximum volume (comparable to the inter-observer variability of manual tracings). The automated tool required no user interaction in 93% of the recordings, while 4% required a single click and only 2% required contour adjustments, reducing considerably the amount of time and effort required for LA volumetric analysis. Conclusion The automated tool was validated in a multi-centre setting, providing quantification of the LA volume over the cardiac cycle with minimal user interaction. The results of the automated analysis were in agreement with those estimated manually by experts. This study shows that such approach has clinical utility for the assessment of the LA morphology and function, automating and facilitating the time-consuming task of analysing 3D echocardiographic recordings.
  •  
2.
  • Boles, Usama, et al. (författare)
  • Patterns of coronary artery ectasia and short-term outcome in acute myocardial infarction
  • 2014
  • Ingår i: Scandinavian Cardiovascular Journal. - : Informa UK Limited. - 1401-7431 .- 1651-2006. ; 48:3, s. 161-166
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective. To assess the relationship between hematological inflammatory signs, cardiovascular risk (CV) factors and prognosis in patients presenting with acute myocardial infarction (AMI) and coronary artery ectasia (CAE). Design. We investigated 3321 AMI patients who required urgent primary percutaneous intervention in two centres in the United Kingdom between January 2009 and August 2012. Thirty patients with CAE were compared with 60 age-and gender-matched controls. Blood was collected within 2 h of the onset of chest pain. CV risk factors were assessed from the records. Major acute cardiac events and/or mortality (MACE) over 2 years were documented. Results. CAE occurred in 2.7% and more often affected the right (RCA) (p = 0.001) and left circumflex artery (LCx) (0.0001). Culprit lesions were more frequently related to atherosclerosis in non-CAE patients (p = 0.001). Yet, CV risk factors failed to differentiate between the groups, except diabetes, which was less frequent in CAE (p = 0.02). CRP was higher in CAE (p = 0.006), whereas total leucocyte, neutrophil counts and neutrophil/lymphocyte ratio (N/L ratio) were lower (p = 0.002, 0.002 and 0.032, respectively) than among non-CAE. This also was the case in diffuse versus localised CAE (p = 0.02, 0.008 and 0.03, respectively). The MACE incidence did not differ between CAE and non-CAE (p = 0.083) patients, and clinical management and MACE were unrelated to the inflammatory markers. Conclusion. In AMI, patients with CAE commonly have aneurysmal changes in RCA and LCx, and their inflammatory responses differ from those with non-CAE. These differences did not have prognostic relevance, and do not suggest different management.
  •  
3.
  • Pedrosa, Joao, et al. (författare)
  • Automatic Short Axis Orientation of the Left Ventricle in 3D Ultrasound Recordings
  • 2016
  • Ingår i: MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY. - : SPIE-INT SOC OPTICAL ENGINEERING. - 9781510600256
  • Konferensbidrag (refereegranskat)abstract
    • The recent advent of three-dimensional echocardiography has led to an increased interest from the scientific community in left ventricle segmentation frameworks for cardiac volume and function assessment. An automatic orientation of the segmented left ventricular mesh is an important step to obtain a point-to-point correspondence between the mesh and the cardiac anatomy. Furthermore, this would allow for an automatic division of the left ventricle into the standard 17 segments and, thus, fully automatic per-segment analysis, e.g. regional strain assessment. In this work, a method for fully automatic short axis orientation of the segmented left ventricle is presented. The proposed framework aims at detecting the inferior right ventricular insertion point. 211 three-dimensional echocardiographic images were used to validate this framework by comparison to manual annotation of the inferior right ventricular insertion point. A mean unsigned error of 8, 05 degrees +/- 18, 50 degrees was found, whereas the mean signed error was 1, 09 degrees. Large deviations between the manual and automatic annotations (amp;gt; 30 degrees) only occurred in 3, 79% of cases. The average computation time was 666ms in a non-optimized MATLAB environment, which potentiates real-time application. In conclusion, a successful automatic real-time method for orientation of the segmented left ventricle is proposed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy